The CERA-PET Blood Glucose Monitoring System is intended for use in veterinary and medical professional setting to monitor blood glucose level in dogs and cats. It is also intended for use in the home setting to monitor blood glucose levels in dogs and cats. The CERA-PET Blood Glucose Monitoring System is intended for in vitro diagnostic use.
Best quality steel use in the manufacturing of instruments. Standard lot
Interlocking nail, locking plates (lcp), external fixture, trauma, dhs/ dcs plate, small and large fragment bone screws and screws, austin moore prosthesis, thompson prosthesis, pin, wires and drill, bone tape etc On demand
Type: velas 30a Power: 30w Wavelength: 810 nm Lifetime: over 20000 hours Warranty: 12 months free warranty, 5 years technical support Packing: carry case with carton Standard configuration: 1 pc of 600um, 1 pc of 400um bare fiber, 1 pc of fiber cutter, 1 pc of fiber stripper, 2 pc of safety goggles, 1 pc footswitch and 1 pc surgical hand piece. Packing dimension: 74*55*46cm Net weight: 13 kg Gross weight: 34 kg Packing: carry case with carton
Feline leukemia virus ag rapid test Eterinarian. For an accurate result, it is suggested to Apply other method such as elisa for final determination in practice. In house standard
R 10 minutes is considered invalid. Interpretation of results Positive: only clear c band appears. Negative: the presence of both c band and t band. Invalid: no colored band appears in c zone regardless of whether t band appears. Specificity The results are negative when the rapid test is applied to detect 100 ppm of chloramphenicol, aminoglycosides, tetracyclines, macrolides and sulfonamides. Storage All materials must be stored at 2-8¡ãc. The test kit is stable through the expiration date (12 months) marked on the foil pouch. Do not store the test kit in direct sunlight. Precaution 1. For best results, please strictly adhere to these instructions. 2. All reagents must be at room temperature before running the assay. 3. Do not remove rapid test from its pouch until immediately before use. 4. The milk sample should be fresh and homogeneous liquid without caking and precipitation. 5. Do not reuse the test strip. 6. Do not use the test beyond its expiration date marked on the foil pouch. 7. Do not use water, powdered milk as negative control. Use confirmed negative fresh milk as control. 8. The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitation Beta-lactam rapid test is an useful tool offering a rapid and accurate testing in field screening, exceeding with its convenience. If you want a quantitative result, it is suggested to apply other method such as elisa / hplc in practice. In house standard
1.Do centrifugation to cattle¡¯s whole blood sample to collect serum or plasma for use. 2.Take out the cassette from the foil pouch and place it horizontally. 3.Drip 1 drop of serum into the sample hole ¡°s¡± and immediately drip 1 drop of assay buffer. 4.Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. Interpretation of results Positive: the presence of both c band and t band, no matter t band is clear or vague. Negative: only clear c band appears. Invalid: no colored band appears in c zone, no matter whether t band appears. Storage The kit can be stored at room temperature (2-30¡ãc). The test kit is stable through the expiration date (18 months) marked on the foil pouch. Do not freeze. Do not store the test kit in direct sunlight. Precaution 1.For best results, please strictly adhere to these instructions. 2.All reagents must be at room temperature before running the assay. 3.Do not remove test cassette from its pouch until immediately before use. 4.Do not reuse the test kit. 5.Do not use the test beyond its expiration date marked on the foil pouch. 6.The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitation Bovine brucella ab rapid test is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, it is suggested to apply other method such as elisa for final determination in practice. In house standard
4. Centrifugal tubes (each containing 180 ¦ìl of assay buffer) 5. Product manual Test procedure 1. Do centrifugation to cattle¡¯s whole blood sample to collect serum or plasma for use. 2. Use small pipette with reticle to transfer 20 ¦ìl (upper reticle) of serum or plasma into the centrifugal tube with assay buffer. Mix them well by the pipette attached in the pouch. 3. Take out the cassette from the foil pouch and place it horizontally. 4. Drip 3 drops (about 100 ¦ìl) of sample mixture into the sample hole. 5. Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. Interpretation of results Positive: the presence of both c band and t band, no matter t band is clear or vague. Negative: only clear c band appears. Invalid: no colored band appears in c zone, no matter whether t band appears. Storage The kit can be stored at room temperature (2-30¡ãc). The test kit is stable through the expiration date (18 months) marked on the foil pouch. Do not freeze. Do not store the test kit in direct sunlight. Precaution 1. For best results, please strictly adhere to these instructions. 2. All reagents must be at room temperature before running the assay. 3. Do not remove test cassette from its pouch until immediately before use. 4. Do not reuse the test kit. 5. Do not use the test beyond its expiration date marked on the foil pouch. 6. The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitation Bovine tuberculosis ab rapid test is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, it is suggested to apply other method such as elisa for final determination in practice. In house standard
Ed. If only one red line appears, it indicates that the cow is not Pregnant, p4 is in the lowest level at this moment. It is recommended to make the best use of this time to Because the diary cow¡¯s estrous cycle is 18-22 days, it is suggested to perform the test the 18th days after . In order to get reliable result, give up the first three Milking and then collect sample milk around 5-10ml. Mix the sample milk well before testing. Urine and blood Positive: if both t band and c band are visible, the test result is positive, which means the cow is pregnant or In middle period of estrous cycle. Negative: if only c line is visible, the test result is negative, which indicates the cow is not pregnant. Invalid: when control line does not appear on the membrane, the test is invalid due to improper test Procedure or deterioration of reagents. It is recommended that the test be repeated. Precaution (1) test according to the law of the estrous cycle strictly. (2) for single use only; do not reuse the test devices. (3) don¡¯t keep the strip or cassette in the air for a long time after unpacking. (4) while performing the test, make sure that the surface of sample should not exceed the ¡°max¡± line of strip. (5) do not use test kit after expiry date. Validity and storage The period of the validity is 24 months. Store as packaged in the sealed pouch under the room temperature. Avoid light. In house standard
Beta-lactam rapid test Interpretation of results Positive: only clear c band appears. Negative: the presence of both c band and t band. Invalid: no colored band appears in c zone regardless of whether t band appears. Specificity The results are negative when the rapid test is applied to detect 100 ppm of chloramphenicol, aminoglycosides, tetracyclines, macrolides and sulfonamides. Storage All materials must be stored at 2-8¡ãc. The test kit is stable through the expiration date (12 months) marked on the foil pouch. Do not store the test kit in direct sunlight. Precaution 1.For best results, please strictly adhere to these instructions. 2.All reagents must be at room temperature before running the assay. 3.Do not remove rapid test from its pouch until immediately before use. 4.The milk sample should be fresh and homogeneous liquid without caking and precipitation. 5.Do not reuse the test strip. 6.Do not use the test beyond its expiration date marked on the foil pouch. 7.Do not use water, powdered milk as negative control. Use confirmed negative fresh milk as control. 8.The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitation Beta-lactam rapid test is an useful tool offering a rapid and accurate testing in field screening, exceeding with its convenience. If you want a quantitative result, it is suggested to apply other method such as elisa / hplc in practice. Depend on quantity
1.Insemination instruments straw 2.Material: pe 3.Packing: 1000pcs/bag, 50bags/ctn 4.Color: optional 5.Best prices
1.Flushing tube in veterinary instruments 2.Material:pe 3.Use: for cattle 4.Factory price
1.Artificial insemination gun for cattle 2.Material:304# stainless steel 3.Easy to use 4.Use: a.I. Cow
1measuring range0mgs199.9mgs 2frequency of the probe: 8mhz 3specification of the blood pressure cuff Range: no.1 4.2cm7.1cm No.2 5.4cm9.1cm No.3 6.9cm11.7cm No.4 9cm13cm No.5 12cm16cm ( no.6 :17cm22cm optical additional charge $15) 4 rechargeable battery voltage7.4v 1500mah) 5ac input: 100240v 50/60hz dc output dc8.4v1000ma 6continuous working time :> 8 hours 7speaker: 4¦¸, 1w Weight: 3.8kg Package: 45*35*23cm aluminum alloy box
Gssi In Surgical & Veterinary We Proudly introduce ourselves as the One and the Only Manufacturer of GSSI BURDIZZO CASTRATOR AND GSSI POST MORTEM KITS IN INDIA. There are no other manufacturers of these items. 9" 12" 18" 19" weight 1.5 to 2 kg.
Vaginal speculum
Size: 48 cm.
Fresh, clean, uncontaminated drinking water flows out the hollow nipple control into the hogí»s mouth. Shuts off automatically. All stainless steel. Works on the pressure 10-100 psi. Standard 1/2" male pipe thread. Adjustable water flow. No training problem. Proven performance, guaranteed satisfaction. Lets animals í¦nurseí¦ water from a mechanical nipple using a biting action that eliminates water waste from play and accidental operation. The valve screws directly onto a t or elbow to the main pressure line. Install 6" to 8" from a corner to prevent animals from using the drinker as a scratcher. Every valve has three different orifices for high/medium/low water pressure. One nipple drinker will service 12 pigs up to market size. 1/2" npt.
Fresh, clean, uncontaminated drinking water flows out the hollow nipple control into the hogí»s mouth. Shuts off automatically. All stainless steel. Works on the pressure 10-100 psi. Standard 1/2" male pipe thread. Adjustable water flow. No training problem. Proven performance, guaranteed satisfaction. Lets animals í¦nurseí¦ water from a mechanical nipple using a biting action that eliminates water waste from play and accidental operation. The valve screws directly onto a t or elbow to the main pressure line. Install 6" to 8" from a corner to prevent animals from using the drinker as a scratcher. Every valve has three different orifices for high/medium/low water pressure. One nipple drinker will service 12 pigs up to market size. 1/2" npt.
Fresh, clean, uncontaminated drinking water flows out the hollow nipple control into the hogí»s mouth. Shuts off automatically. All stainless steel. Works on the pressure 10-100 psi. Standard 1/2" male pipe thread. Adjustable water flow. No training problem. Proven performance, guaranteed satisfaction. Lets animals í¦nurseí¦ water from a mechanical nipple using a biting action that eliminates water waste from play and accidental operation. The valve screws directly onto a t or elbow to the main pressure line. Install 6" to 8" from a corner to prevent animals from using the drinker as a scratcher. Every valve has three different orifices for high/medium/low water pressure. One nipple drinker will service 12 pigs up to market size. 1/2" npt. Standard export packing, 100 pcs/box size:45x20x10mm 400 pcs/ctn