4. Centrifugal tubes (each containing 180 ¦ìl of assay buffer)
5. Product manual
Test procedure
1. Do centrifugation to cattle¡¯s whole blood sample to collect serum or plasma for use.
2. Use small pipette with reticle to transfer 20 ¦ìl (upper reticle) of serum or plasma into the centrifugal tube with assay buffer. Mix them well by the pipette attached in the pouch.
3. Take out the cassette from the foil pouch and place it horizontally.
4. Drip 3 drops (about 100 ¦ìl) of sample mixture into the sample hole.
5. Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.
Interpretation of results
Positive: the presence of both c band and t band, no matter t band is clear or vague.
Negative: only clear c band appears.
Invalid: no colored band appears in c zone, no matter whether t band appears.
Storage
The kit can be stored at room temperature (2-30¡ãc). The test kit is stable through the expiration date (18 months) marked on the foil pouch. Do not freeze. Do not store the test kit in direct sunlight.
Precaution
1. For best results, please strictly adhere to these instructions.
2. All reagents must be at room temperature before running the assay.
3. Do not remove test cassette from its pouch until immediately before use.
4. Do not reuse the test kit.
5. Do not use the test beyond its expiration date marked on the foil pouch.
6. The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.
Limitation
Bovine tuberculosis ab rapid test is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, it is suggested to apply other method such as elisa for final determination in practice.
In house standard
Tb(tuberculosis) rapid test antibodies (uncut sheet) Specimen: whole blood/serum/plasma Format:2.5mm 3.0mm 4.0mm Accuracy:99.6% Sensitivity:100% Specificity:98.2% Package: in bulk or unit box package for your options Delivery date:7-10 days after receipt of the payment Pouch design: white pouch / netrual/ oem design/ce marked Payment:westren union, t/t
1.Do centrifugation to cattle¡¯s whole blood sample to collect serum or plasma for use. 2.Take out the cassette from the foil pouch and place it horizontally. 3.Drip 1 drop of serum into the sample hole ¡°s¡± and immediately drip 1 drop of assay buffer. 4.Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. Interpretation of results Positive: the presence of both c band and t band, no matter t band is clear or vague. Negative: only clear c band appears. Invalid: no colored band appears in c zone, no matter whether t band appears. Storage The kit can be stored at room temperature (2-30¡ãc). The test kit is stable through the expiration date (18 months) marked on the foil pouch. Do not freeze. Do not store the test kit in direct sunlight. Precaution 1.For best results, please strictly adhere to these instructions. 2.All reagents must be at room temperature before running the assay. 3.Do not remove test cassette from its pouch until immediately before use. 4.Do not reuse the test kit. 5.Do not use the test beyond its expiration date marked on the foil pouch. 6.The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitation Bovine brucella ab rapid test is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, it is suggested to apply other method such as elisa for final determination in practice. In house standard
General Information Method: Double Antigens Sandwich Method Sensitivity : 99.5% Specificity : 98.8% Specimen : Serum / Plasma Reading Time : 5- 10 min
The H pylori can be utilized as a rapid screening process for large populations of patients and highly indicated in the early diagnosis of H pylori infection as the immune response can often precede clinical manifestations of disease From a diagnostic point of view, a high serum level specific antibodies against H pylori must be interpreted as an indication of type B asymptomatic gastritis Specification: Specimen:Serum/plasma/whole blood Sensitivity:96% Specificity:90% Packaging:25 cassettes/box, Certificate:CE and ISO 13485 Raw materials is imported from US OEM packaging is available
KOSTEC can supply Korean rapid test kits, which are not only faster and easier in test but alsoprovide accurater test results. Also price is very much attractive! If you have any interest in this test kits, do not hesitate to contact me. Thanks!
Canine brucella ab rapid test is a lateral flow immunoassay for quick detection of brucella canis in serum. Welcome your enquiry! Specifications Specimens: serum Shelf life: 18 months Storage temperature: room temperature(2-30c degree) 10 tests per kit, sealed in foil pouch
Product Details: Number of Reactions(Preps)/Kit :30T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 10 min CAT No : RK019-30 STANDARD Q HIV 1/2 Ab 3-Line performs qualitative analysis by detecting antibodies specific to HIV-1 (including Group O) and HIV-2 in serum, plasma and whole blood using immunochromatography. With a simple test method, HIV infection status can be discriminated, and with its high sensitivity and specificity, the screening test result can be obtained within 10 minutes. Easy to use, Easy to read and interpret Discrimination between HIV-1 and HIV-2 antibodies Room temperature storage Performance Sensitivity : 100% (74/74)/ Specificity : 100% (232/232)
The Chagas Ab Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of IgG anti-Trypanosoma cruzi (T. cruzi) in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with T. cruzi. Any reactive specimen with the Chagas Ab Rapid Test must be confirmed with alternative testing method(s) and clinical findings. Chagas disease is an insect-borne, zoonotic infection by the protozoan T. cruzi, which causes a systemic infection of humans with acute manifestations and long term sequelae. It is estimated that 16-18 million individuals are infected worldwide, and roughly 50,000 people die each year from chronic Chagas disease (World Health Organization)1. Buffy coat examination and xenodiagnosis used to be the most commonly methods2,3 in the diagnosis of acute T. cruzi infection. However, both methods are either time consuming or lack of sensitivity. Recently, serological test becomes the mainstay in the diagnosis of Chagasâ??s disease. In particularly, recombinant antigen based tests eliminate false-positive reactions which are commonly seen in the native antigen tests4-5. The Chagas Ab Rapid Test is an instant antibody test which detects IgG antibodies the T. cruzi within 15 minutes without any instrument requirements. By utilizing T. cruzi specific recombinant antigen, the test is highly sensitive and specific.
INTENDED USE Feline Immunodeficiency Virus Ab Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Feline Immunodeficiency Virus antibody (FIV Ab) in cat's blood. PRINCIPLE OF THE ASSAY Feline Immunodeficiency Virus Ab Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FIV antibody in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FIV antibody in the sample. INTERPRETATION OF RESULTS Positive: The presence of both C band and T band, no matter T band is clear or vague. Negative: Only clear C band appears. Invalid: No colored band appears in C zone, no matter whether T band appears. STORAGE The kit can be stored at room temperature (2-30C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.