1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: Ie is Rated current of main circuit.
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: Ie is Rated current of main circuit.
Vacuum Circuit Breaker HVD1-12KV 1250A 25KA VCB with copper parts 210mm phase distance HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15®C~+40®C; 3.2 Environment humidity: Daily average relative humidity:95%, monthly average relative humidity:90%; Daily average saturated vapor pressure:2.210-3Mpa,monthly average saturated vapor pressure:1.810-3Mpa; 3.3 Altitude: Not exceed 1000m; 3.4 Earthquake intensity: Not exceed°ree; 3.5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration. 1.Main specifications and technical parameters Rated voltage: 12 kv Rated lightning impulse withstand voltage(1min): 75 kv Rated short-time power frequency withstand voltage (1min): 42 kv Rated short-circuit breaking current: 25KA Rated current: 1250A Rated peak withstand current: 63KA Rated shorted-time withstand current: 25KA Rated shorted-time making current(peak): 63KA Power frequency withstand voltage of secondary circuit(1min): 2000 v Opening time(rated voltage): 20~50 ms Closing time(rated voltage): 30~70 ms Rated short-circuit current breaking times: 50(40kA 30) times Mechanical life: 30,000 times
Model No.: TD 12kv 1600A 31.5KA (JUC618A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1600A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1600A 31.5A (JUC619) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1600A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
Model No.: TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 31.5KA (JUC619A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
1. General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: =2ms Contacts re-bouncing clearance at opening operation: =2mm Synchronism of three phases: =1ms
Model No.: JTD 12kv 1250A 20KA vacuum interrupter for Solid embedded poles Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage (1 min): 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 20KA Rated short circuit making current(peak value): 50KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 20KA Rated withstand current(peak value): 50KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 70±40 N Force required to hold contacts opening at full stroke: 120±50 N Circuit resistance at lowest rated contacts force: =35µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Weight of moveable parts: =0.7kg Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 7±1 mm Average opening speed: 1.0±0.25 m/s Average closing speed: 0.65±0.15 m/s Rated contacts pressure: 1600±100 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
1. General HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A / 1250A Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: =8 s
HVJ20 series vacuum contactor has higher rated current, smaller size and anti-dusty advantages. It can be used in AC50 ~ 60Hz, 2KV power system, rated current to 800A, for long distance making-breaking and frequent starting and controlling of AC motor.
HVJ5 1.14kv 125A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 125A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
Vacuum capacitor, vacuum relay, vacuum switch, vacuum contactor, vacuum circuit-breaker and coaxial relay.
AC Vacuum Contactor CKJ11-500/3.6 Vacuum contactors are full closed product adopting new technology, which have the characteristics of high operating voltage, small size, stability, long life, reliability, low pick-up power, low circuit resistance, easier maintenance and so on comparing with the traditional CKJ5 contactors. CKJ11 contactors have got the national patent.
AC Vacuum Contactor CKJ11-500/3.6 Vacuum contactors are full closed product adopting new technology, which have the characteristics of high operating voltage, small size, stability, long life, reliability, low pick-up power, low circuit resistance, easier maintenance and so on comparing with the traditional CKJ5 contactors. CKJ11 contactors have got the national patent.
HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment.
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.
HVJ30-1.14/1000ã?�1250 series AC vacuum contactor is applicable for AC 50HZ power system of rated voltage 1.14KV and rated current up to 1000 Aï½?1250Ato open and close circuit, start and control AC motor frequently. It is suitable for composed magnetic starter with various protective devices (JDB electronic integrated protector, JR9 type over current protection device, resistance-capacitance absorbers). It is particularly suitable for compose a explosion-proof magnetic starter and large mineral switchgear.
Vacuum contactor, vacuum interrupter, vacuum circuit breaker.