Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB
Main technical parameters
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage: 42 KV
Rated lightning impulse withstand voltage: 75 KV
Rated short circuit breaking current: 25KA
Rated short circuit making current(peak value): 63KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 25KA
Rated withstand current(peak value): 63KA
Rated duration of short circuit: 4S
Mechanical life: 20,000 times
Closing force due to bellows and atmosphere: 120±50N
Force required to hold contacts opening at full stroke: 190±50N
Circuit resistance at lowest rated contacts force: =20µO
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 2000±200N
Contacts bouncing duration at closing operation: =2ms
Contacts re-bouncing clearance at opening operation: =2mm
Synchronism of three phases: =1ms
Model No.: TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 31.5KA (JUC619A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
Supplier: Branded consumer electronics, televisions, cameras, home appliances, car audio systems, hair curlers, hair trimmers, hair clippers, hair straighteners, beard trimmers, shavers, vacuum cleaners, air purifiers, blenders, mixers, juicers etc, mg3710/15 mg3730/15 mg5720/15 mg7720/15 bt1233/14 bt3206/14 bt3216/14
Supplier: Woven/knit and non woven fabric and its relative products like disposable medical products, home/hotel textiles, essential oils, household appliances, kitchenware, fiberglass mesh cloth, etc.
Supplier: Juicer, mixer grinder, pressure cooker, electric iron, toaster, frying pan, water purifier, water dispenser, mixer/blender, dry iron, kettle, gas stove , non stick cookware, water heater, air cooler, water purifier, electric chimney system ceiling fan others, kitchen appliances, range hood
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: �20μΩ Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: �2ms Contacts re-bouncing clearance at opening operation: �2mm Synchronism of three phases: �1ms Items Value Rated voltage 12KV Rated current 1250A Rated frequency 50Hz Rated power frequency withstand voltage 42kV Rated lightning impulse withstand voltage 75kV Rated short circuit breaking current 25KA Rated short circuit making current(peak value) 63KA Breaking operations under rated short circuit breaking current 30 times Rated short time withstand current 25kA Rated withstand current(peak value) 63kA Rated duration of short circuit 4s Mechanical life 20000 times Closing force due to bellows and atmosphere 120±50N Force required to hold contacts opening at full stroke 190±50N Circuit resistance at lowest rated contacts force �20μΩ Storage life 20 years Limiting abrasion of contacts 3mm  Mechanical requiements of vacuum circuit breaker Items Value Clearance between opening contacts 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance) 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position) 0.6±0.2 m/s Rated contacts pressure 2000±200N Contacts bouncing duration at closing operation �2ms Contacts re-bouncing clearance at opening operation �2mm Synchronism of three phases �1ms
1. Brief introduction TD 33KV 36kv 1600A 25KA (JUC632) vacuum interrupter for VCB The interrupter adoption porcelain and ceramics lagging makes to insulate the outer shell. Contact is CuCr metal alloy material advanced technique of cup construction, break the discharge big. Insulate the level high, breaking the abiliting strong, the life span is long, mainten anle is sample, no explosion dangerous, no contaminate and the noise is low. The load switch main used electric power, machine, coal mine, chemical engineering, petroleum metallurgy etc. power transmission system used control with protect. more than keeping with at the multifarious operation. Rated voltage: 33KV 36KV Rated current: 1600A Rated short-circuit breaking current: 25KA Rated short-circuit making current: 63KA Rated peak withstand current: 63KA Rated short-time withstand current: 25KA Rated short-circuit continuous time: 4 s Rated single capacitor unit breaking current: 630A Rated back to back capacitor unit breaking current: 400A Rated short-time (1 min) withstand voltage: 95 KV Rated contact pressure time-limit loop resistive: =25µO Rated short-circuit breaking current breaking times: 30 Ops Rated lightning impulse withstand voltage: 185 KV Mechanical life: 10,000 Ops Contact automatic: 200±50 N Force required to hold contacts open at full stroke: 300±50 N Contact-wear allowance thickness: 3 mm Internal gas pressure: =1.33×10-3 Pa Shelf life: 20 years
Model No.: JTD 12kv 1250A 20KA vacuum interrupter for Solid embedded poles Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage (1 min): 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 20KA Rated short circuit making current(peak value): 50KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 20KA Rated withstand current(peak value): 50KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 70±40 N Force required to hold contacts opening at full stroke: 120±50 N Circuit resistance at lowest rated contacts force: =35µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Weight of moveable parts: =0.7kg Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 7±1 mm Average opening speed: 1.0±0.25 m/s Average closing speed: 0.65±0.15 m/s Rated contacts pressure: 1600±100 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1600A 31.5KA (JUC618A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1600A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms