1.Introduction JCZ5 7.2 kv vacuum contactor HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 7.2 kv Control voltage: 110V, 220V Rated current: 200A, 400A, 630A Contacts separation: 4.5+1-0.5mm Over travel: 1.5±0.5 mm Main circuit power frequency voltage withstand: 32000 V Auxiliary circuit power frequency withstand voltage: 2500 V Control circuit power frequency withstand voltage: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 28KG
1.Introduction JCZ5 12kv vacuum contactor HVJ6-12 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 12KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 12000 v Control circuit: 110V 220V Rated current: 200A 400A 630A Contacts separation: 5+1-0.5 mm Over travel: 1.5±0.5 mm Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency voltage withstand: 2500 v Control circuit power frequency voltage withstand: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 32KG
Supplier: Vacuum interrupter for vacuum contactor, vacuum interrupter for circuit breaker, vacuum interrupter for circuit breaker embedded pole, vacuum interrupter for load break switch, solid embedded poles for circuit breaker, AC vacuum contactor, high voltage AC vacuum contactor, vacuum circuit breaker, high voltage current-limiting fuse
Services: Export trader
HCJ5 1.14kv 1000A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environmen 2. Vacuum Tube main technical parameter Rated voltage: 1.14 kv Rated current: 1000 A Rated put through current: 10000A Rated breaking current: 8000A Limiting breaking current: 10000A Rated short-time withstand current: 8000A Rated short-time withstand voltage(1 min): 10 kv Mechanical life: 1000000 times Rated breaking time AC3: 150000 times Rated breaking time AC4: 6000 times Automatic closing force of the contacts: 70±20 N Force required to hold contacts open at full stork: 90±20 N Contact automatic blocking ability loop electrical resistance: 80 Contact-wear allowance thickness: 2 mm Shelf life: 20 years Internal gas pressure: 1.3310-3 Pa
HCJ5 1.14kv 125A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environment 2. Vacuum Tube main technique parameter Rated voltage: 1.14 kv Rated current: 125A Rated making current: 1250A Rated breaking current: 1000A Limiting breaking current: 1250A Rated short-time withstand current: 1000A Rated short-time withstand voltage: 10 kv Mechanical life: 1000000 times Breaking operations AC3: 150000 times Breaking operations AC4: 6000 times Automatic closing force of the contacts: 25±10 N Force required to hold contacts open at full stork: 40±10 N Circuit resistance at lowest rated contacts force: 120 Limiting abrasion of contacts: 2 mm Storage life: 20 years Internal gas pressure: 1.33 10-3 Pa
HCJ3 7.2kv 630A vacuum interrupter for vacuum contactors 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long maintenance is simple .no explosion dangerous no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 7.2 kv Rated current: 630A Rated making current: 6.3KA Rated breaking current: 5.04KA Limiting breaking current: 6.3KA Rated short-time withstand current: 6.3KA Rated short-time withstand voltage: 32 kv Rated lighting impulse voltage: 60 kv Circuit resistance at lowest rated contacts force: 80 Electrical life: 250,000 times Mechanical life: 500,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: 1.3310-3 Pa Storage life: 20 years
HCJ3 12KV 630A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple ,no explosion dangerous, no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 12 kv Rated cureent: 630A Rated making current: 6.3KA Rated breaking current: 5.04KA Limiting breaking current: 6.3KA Rated short-time withstand current: 6.3KA Rated short-time withstand voltage: 42 kv Rated lighting impulse voltage: 75 kv Circuit resistance at lowest rated contacts force: 80 Electrical life: 250,000 times Mechanical life: 5000,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: 1.3310-3 Pa Storage life: 20 years
Vacuum circuit breaker serves in the power system of 10kv and three-phase ac 50hz to function as switching different kinds of loads needing frequent operation, and can protect and control electric equipment in the industrial & mineral enterprise, power plant and substation as well. It can coordinate with the kyn28a-12(gzs1) middle-arranged manual-driven switchgear or xgn- stantionary switchger as well. Main technical parameter: Rated voltage 12kv Rated current 630~3150a Rated short-circuit breaking current 20~40ka Rated peak withstand current 50~100ka Rated short-time withstand current 20~40ka Rated duration short-time 4s Machanical endurance 20000 times Carton package