1. General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:
1. General HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A / 1250A Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: =8 s
1.General HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required. 2. Service conditions 2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?. 2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa. 2.3 Altitude: Not exceed 1,000m. 2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et… Main specifications and technical parameters Rated voltage: 33KV 36kv Power frequency withstand voltage: 95 kv Lighting impulse withstand voltage: 185 kv Rated current: 1250A, 1600A, 2000A Rated short-time withstand current: 25KA, 31.5KA Rated peak value withstand current: 63KA, 80KA Rated short-circuit duration: 4 s Rated short-circuit breaking current: 25KA, 31.5KA Rated short-circuit making current: 63KA, 80KA Rated operation sequence: O-0.3s-CO-180s-CO Breaking time:
1. Introduction HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers. HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current. 2. Applicable environment 3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area); 3.2Altitude should not exceed 2000m(over 2000m is plateau type); 3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s); 3.4Air pollution degree: 3,that of antifouling type:4; 3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration. 1. Main technical parameters Rated voltage: 33kv 36KV 1 minute power frequency withstand voltage, dry test: 95 kv 1 minute power frequency withstand voltage, wet test: 80 kv Lightning impulse withstand voltage(peak value): 185 kv Rated current: 1600A / 2000A Rated short-circuit breaking current: 20KA, 25KA, 31.5KA Rated short-circuit making current(peak): 50KA, 63KA, 80KA Rated operating sequence: O-0.3s-CO-180s-CO Rated short-time withstand current: 20KA, 25KA, 31.5KA Rated peak withstand current: 50KA, 63KA, 80KA Rated short-circuit duration: 4 s Rated control voltage: AC220,110;DC220,110 Rated short-circuit breaking current break times: 20 times Full-break time:
HVJ3 12KV VACUUM CONTACTOR Detailed product description: The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 .Main models and technical parameters Rated voltage: 12 KV Control voltage: 220/110/380 Rated current: 160A, 250A, 400A, 630A Clearance: 5±0.5 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 30KG Note: “Ie” represents the rated current of main circuit
1. General HVJ5 1.14kv 125A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 125A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36V, 110V, 220V, 380V Rated current: 125A Opening distance: 1.8±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 2000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10 S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
HVJ20 series vacuum contactor has higher rated current, smaller size and anti-dusty advantages. It can be used in AC50 ~ 60Hz, 2KV power system, rated current to 800A, for long distance making-breaking and frequent starting and controlling of AC motor. Rated voltage: 2 kv / 2 kv Rated current: 630A / 800A Main circuit making ability (A/100 times): 6300 / 6300 Main circuit break-make ability (A/10 times): 5000 / 6000 Maximum breaking ability (A/3 times): 6300 / 6300 Electrical life AC3(times): 600,000 / 600,000 Electrical life AC4(times): 100,000 / 100,000 Mechanical life(times): 1,000,000 / 1,000,000 Rated operating frequency AC3(times /h): 300 / 300 Rated operating frequency AC4(times /h): 120 / 120 Short-time operating frequency times /h(20S): 1200 / 1200 Clearance between open contacts(mm): 3±0.3 / 3±0.3 Over travel(mm): =1 / =1
HVJ3 7.2KV VACUUM CONTACTOR 1. General The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. 2. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 Main models and technical parameters Rated voltage: 7.2 kv Control voltage: 380/220/110 Rated current: 160A, 250A, 400A, 630A, 800A, 1000A Clearance: 3.5±0.3 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 32000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 25.5 KG Note: “Ie” represents the rated current of main circuit