The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.
1. General HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions Dip switch address setting 125 usable detector address settings per loop
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.
SR-812DC-2 is 2-Wire Network Photoelectric smoke & heat alarm Main features: 1.Power supply non-polar input 2.Infrared photoelectric sensor 3.MCU processing, eliminate false alarm 4. Network LED indicating alarm 5.SMT manufacturer technology, high stability 6.Dustproof, mothproof, anti-light interference design 7.Stainless steel shield in the chamber, anti-RFI(20V/m-1GHz) 8.Execute criterion: GB4715,EN54-7, UL539
SNC-300 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire And high immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting
The 460 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
Snc-300 non-addressable photoelectric smoke/heat detectors are state-of-the-art detectors suitable for connection To 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor Provide early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive Rate-of-rise operation or fixed-temperature operation when the response threshold value is exceeded. Photoelectric smoke and heat sensors Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
Used for signal and data communications of fire alarm systems and generally for fixed indoor installations.
Product Description: SR-A91 Electric bells have been widely used at railroad crossings, in telephones, fire and burglar alarms, as school bells, doorbells, and alarms in industrial plants. Mounted for wall and ceiling applications, indoors or outdoors. Main features: SR-A91 Indoor Fire Bell Voltage: DC24V or DC12V Rated current:20mA Sound pressure: 96dB/m(A) Standard: GA385 Size:150mm Weight :480g Stuff: duralumin
Product Introduction:This product named Manual Call Point,,is usually referred to as an MCP within the fire protection industry, as a "Fire Alarm Call Point" in US, or as a "break glass" in the UK. They are used to allow building occupantsto signal that a fire or other emergency exists within the building. They are usually connected to a central fire alarm panel which is in turn connected to an alarm system in the building, and often to a local fire brigadedispatcher as well.Manual call point is used to initiate an alarm signal.Break glass at the time ofthe fire to issue a signal to a fire alarm control panel,the control panel will showing the serial number of the call point or the location and send out alarm sound once it received the signal. It can be manual alarm systemor part of automatic alarm system. In the case of fire when the glass cover is broken, the push button will be released by the spring action and will actuate an alarm at the control panel through its switching contacts. Inaddition to this, there will be an LED indicator on the control panel for visual indication to locate the call point easily.Product Parameter:Product nameManual Call PointBrand nameYIXINModelYX-BP560TypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalCoverWith water-proof cover optionalColorRed/Green/Yellow/Blue/White optionalBreaked materialGlass sheet(Plastic film on glass)Dimension87*87*52mmWarranty1 YearProduct Feature:1.Available for flush or surface mounting2.Test key inserted from side to test after installation.3.Use plastic film on glass sheet avoid splash of broken pieces and hurt.4.Surface technology: fireproof material, dull polish5.Standard structure: fireproof material shell, easy to install. 6.Suitable for the majority of conventional fire alarm systems.
"Power: DC 3x1.5V AAA battery Sensitivity/alarm time: 30ppm, after 2 hours; 50 ppm, 60~90 minutes; 100 ppm, 10~40 minutes; 300 ppm, within 3 minutes Quiescent current:
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station. Types of Fire Alarm System: All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station. Conventional Fire Alarm System In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes. Addressable Fire Alarm System The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening. Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦. Brands are available : AGNI, MORLEY, NOTIFIER, Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.