Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
2-wire Conventional Heat Detector Heat Alarm Sensor The device is intelligent sensors that utilize a state-of-the-art thermistor sensing circuit for fast response. Features and Benefits 1.Compatible with all the conventional fire alarm control panel 2.Unpolarized wire input 3. Wide range of operating voltages 4. High precision electronic thermistor 5. Built in microprocessor intelligent software 6. wo LEDs blink standby , provide 360° visibility 7. Insect-resistant s creening 8. Twist-on mounting base with tamper lock 9. Remote Indicator LED can be connected. Specifications Installation Temperatures: 14°F to 122°F (-10°C to50°C) Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing Operating Voltage Range: 16 to 32VDC Volts Non-polarized Standby Current: 40µA @ 24 VDC Maximum Alarm Current (LED on: ) �30mA @ 24 VDC Fixed Temperature Rating: 135°F (57°C) Height: 2.2� (55 mm) installed in Base Diameter: 4.0� (103 mm) Weight: 5.5 oz. (155 g)
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel Product Features 1. 2 conventional input zones. 2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex. 3. The panel comes with a 2 amp power supply. 4.Dedicated alarm and trouble relays. 5.1 RS485 can be able to connect the other panel. 6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure. 7. Enclosure supports two 12V, 4Ah backup batteries. 8.The panel can be used independently or connect by RS 485. Specifications Primary AC 120VAC 50/60 Hz Power supply rating 240VAC 50/60 Hz Power supply rating 2 Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 2 Zones Alarm Zone 2 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Normal Quiescent Current (normal status)
Dry contact Ex Double infrared flame detector relay output EXdIICT6 Dry contact Explosion proof Double infrared flame detector Fire alarm relay output Fault relay output IR2 EXdIICT6 Product function and composition A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner Fire alarm. A705/IR2 is converted to electrical si gnal by two infrared pyroelectric sensors which work in different bands. Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time. A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time In the indoor, outdoor and all kinds of special industrial places. Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor Optical window ï¼?white gems (Al2O3) housing L material: aluminum alloy L molding process: Die Casting L coating process: surface electrostatic powder coating, internal metal passivation treatment. The weight is less than 1kg Explosion proof and protection l anti explosion: EXd II CT6 L protection: IP66
2-wire DC powered Conventional Manual Call Point Push Button The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed. Specifications: Operating Voltage Range: 9�32VDC Volts Nominal Operating Resistance: 300Ω Relay Contact Ratings: 2A/30VDC Operating Humidity Range: 95% RH, Non-condensing Operating Temperature Range: -10C to 50C (14F to 122F) Dimensions: W89mm ,H93mm, D26mm Base Dimensions: W87mm ,H87mm, D31.5mm Weight: Net Weight 125g (with base) Colour/Case Material: Red/ ABS
2-wire DC24V Conventional Manual Call Point Broken Glass Button Push Button The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by pull down the plate. The manual call point can be reset by a special key without breaking the glass. Features 1. Compatible with all the conventional fire alarm control panel 2. Can be reset by key without use a new glass 3. 470 Ohm resistance 4. Easy surface mounting Base included Specifications Operating Voltage Range: 9 to 28VDC Volts Alarm Resistance 470ohm/1W Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: -10C to 50C (14F to 122F) Dimensions: Length 140mm, Width 105mm, Depth 45mm Weight: Net Weight 220g
2-wire Conventional Sound Strobe Fire alarm Sound Siren The Sounder strobe is a kind of audible and visual alarm device installed in field, which can be activated by fire alarm control panel in fire control center or by manual call point installed in field. After activated, it will generate strong audible/audible and visual alarm signal to warn people in field. Features 1. Compatible with all the conventional fire alarm control panel 2. Long light life up to 40000 flahsed 3. High sound level up to 100dB Specifications Working voltage: 16VDC to 30VDC. Alarm Current: â?¤ 50mA. Ambient temperature: -10â?? to +55â??. Ambient humidity: â?¤95%RH. Sound level of alarm : â?¥100dB. Flash Intensity: â?¥75CD Flash Period: 40000times Dimensions: 133mmÃ?115mmÃ?50mm L Ã?WÃ?D(With base) Weight: 141g
Key specifications/special features Power source: 9 v battery (included). Audio alarm: & g e; 85 db /3 m Temperature range: 0 to 40 degree Humidity range: 5%-95% relative humidity(rh) Sensor: photoelectric Size: diameter 105 mm in diameter x59 mm depth Interconnects: no Easy to install with mounting base included Suitable for any room Low battery signal Test button for simple testing 100pcs in a carton
Conventional Reflective Optical Beam Smoke detector Beam Detector Beam Alarm Sensor with Relay Output Introduction The Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning. The beam detector has four adjustable operational range of between 8 to 20, 40, 70 and 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB to 4.8dB to meet the specific environmental requirement. The detector works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflectors, it will notify the fire alarm panel when the infrared beam is obscured by smoke. Secure and quick communication through the onboard processor enables the detector to make its own decision and drift compensation resulting in greater automation. The detector is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist. Feature and Benefits 1. Manufacture in compliance with EN54-12 2. Hassle free alignment, built with digital guide display and laser beam pointing 3. Employ single-ended design through reflective mirror. 4. Four ranges wide monitoring from 8-100 meters via encoder 5. Three users programing sensitivity adjustment 6. Built-in microprocessor 7. Self-diagnosis function can monitor for internal faults 8. Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter 9. Fire and Fault interfacing relays 10. Attractive and pleasing appearance 11. Real User friendly alignment method