Product Introduction:This product named Manual Call Point,,is usually referred to as an MCP within the fire protection industry, as a "Fire Alarm Call Point" in US, or as a "break glass" in the UK. They are used to allow building occupantsto signal that a fire or other emergency exists within the building. They are usually connected to a central fire alarm panel which is in turn connected to an alarm system in the building, and often to a local fire brigadedispatcher as well.Manual call point is used to initiate an alarm signal.Break glass at the time ofthe fire to issue a signal to a fire alarm control panel,the control panel will showing the serial number of the call point or the location and send out alarm sound once it received the signal. It can be manual alarm systemor part of automatic alarm system. In the case of fire when the glass cover is broken, the push button will be released by the spring action and will actuate an alarm at the control panel through its switching contacts. Inaddition to this, there will be an LED indicator on the control panel for visual indication to locate the call point easily.Product Parameter:Product nameManual Call PointBrand nameYIXINModelYX-BP560TypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalCoverWith water-proof cover optionalColorRed/Green/Yellow/Blue/White optionalBreaked materialGlass sheet(Plastic film on glass)Dimension87*87*52mmWarranty1 YearProduct Feature:1.Available for flush or surface mounting2.Test key inserted from side to test after installation.3.Use plastic film on glass sheet avoid splash of broken pieces and hurt.4.Surface technology: fireproof material, dull polish5.Standard structure: fireproof material shell, easy to install. 6.Suitable for the majority of conventional fire alarm systems.
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions Dip switch address setting 125 usable detector address settings per loop
The 460 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions
2-wire DC24V Conventional Manual Call Point Broken Glass Button Push Button The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by pull down the plate. The manual call point can be reset by a special key without breaking the glass. Features 1. Compatible with all the conventional fire alarm control panel 2. Can be reset by key without use a new glass 3. 470 Ohm resistance 4. Easy surface mounting Base included Specifications Operating Voltage Range: 9 to 28VDC Volts Alarm Resistance 470ohm/1W Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: -10C to 50C (14F to 122F) Dimensions: Length 140mm, Width 105mm, Depth 45mm Weight: Net Weight 220g
SR-812DC-2 is 2-Wire Network Photoelectric smoke & heat alarm Main features: 1.Power supply non-polar input 2.Infrared photoelectric sensor 3.MCU processing, eliminate false alarm 4. Network LED indicating alarm 5.SMT manufacturer technology, high stability 6.Dustproof, mothproof, anti-light interference design 7.Stainless steel shield in the chamber, anti-RFI(20V/m-1GHz) 8.Execute criterion: GB4715,EN54-7, UL539
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
2-wire DC powered Conventional Manual Call Point Push Button The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed. Specifications: Operating Voltage Range: 9�32VDC Volts Nominal Operating Resistance: 300Ω Relay Contact Ratings: 2A/30VDC Operating Humidity Range: 95% RH, Non-condensing Operating Temperature Range: -10C to 50C (14F to 122F) Dimensions: W89mm ,H93mm, D26mm Base Dimensions: W87mm ,H87mm, D31.5mm Weight: Net Weight 125g (with base) Colour/Case Material: Red/ ABS
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel Product Features 1. 2 conventional input zones. 2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex. 3. The panel comes with a 2 amp power supply. 4.Dedicated alarm and trouble relays. 5.1 RS485 can be able to connect the other panel. 6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure. 7. Enclosure supports two 12V, 4Ah backup batteries. 8.The panel can be used independently or connect by RS 485. Specifications Primary AC 120VAC 50/60 Hz Power supply rating 240VAC 50/60 Hz Power supply rating 2 Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 2 Zones Alarm Zone 2 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Normal Quiescent Current (normal status)
Product Description: SR-A91 Electric bells have been widely used at railroad crossings, in telephones, fire and burglar alarms, as school bells, doorbells, and alarms in industrial plants. Mounted for wall and ceiling applications, indoors or outdoors. Main features: SR-A91 Indoor Fire Bell Voltage: DC24V or DC12V Rated current:20mA Sound pressure: 96dB/m(A) Standard: GA385 Size:150mm Weight :480g Stuff: duralumin
Supplier: fire alarm control panel(fire detection system), fire detector, photoelectric smoke detector, heat detector, fire alarm bell, strobe siren, manual call point, LPG/natural gas detector, Carbon monoxide alarm, PIR detector(Motion detector) home security products