1. General
HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
Model No. SR-812PC-2 Operating voltage DC9~35V Alarm temperature N/A Static current 20uA Alarm current 35mA@DC12V;83m@DC24V Alarm output Remote LED indicator Installation Ceiling mounted Sensitivity 2.06%ft±1.3%ft Working environment -10~+50(â?¤95%RH No congelation) Dimension 100*46mm
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc. 1. Specifications a. Four Style B (Class B) Initiating Device Circuits (IDCs). b. All zones accept two-wire smoke detectors and any normally-open contact devices. c. One built-in Fire Fighting Ouput. d. 24-volt operation. e. Resettable four-wire smoke detector power @ 500 mA. f. Non-resettable power @ 500 mA. g. One-man walk-test programmable for silent or audible test. h. Disable/Enable control per IDC. i. Reverse polarity protection.
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
Supplier: Smoke, heat, gas, co detectors alarm, conventional, addressable fire alarm control panel, sounder
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)