Key Specifications/Special Features Technical data Type JFY-7701 Current range 1-100A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,undervurrent, locked-rotor,phase loss, phase unbalance Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70*35*72 mm Mounting screw fixing Features â?? Compact modular size with integrative structure â?? Built-in LED and keypad afford a precise,digital setting â?? Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance â?? Adjustable reset mode:automatic reset or manual reset â?? Adjustable power-on delay â?? 1 C/O contact Protective Functions â?? Short-circuit â?? Locked-rotor â?? Overcurrent â?? Undercurrent â?? Phase loss â?? Phase unbalance â?? failure warning Typical Applications â?¢ Pumps â?¢ Fans â?¢ Blowers â?¢ Motors â?¢ Compressors Approvals â?¢ CE â?¢ ROHS Main Export Markets Asia Australasia Eastern Europe Mid East/Africa North America Western Europe Central/South America -
.1 Key Specifications/Special Features Technical data Type JFY-813 Current range 1-10A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,undervurrent, locked-rotor,phase loss, phase unbalance Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
I posted below a load of LCD Monitors that is currently available and looking for best offers only. The load is packaged in 40 gaylord boxes and will fill a 40' HC container. I attached our grading chart which details each grade in this load with associated pictures. I also attached pictures of this stock for your easy reference. LCD stands will be included with the load, but since they are removed we cannot guarantee all stands match the LCD monitors in this load. Grade A LCD Monitors 19" Widescreen 730 units 22 Widescreen 528 units 24 Widescreen 148 units Grade B LCD Monitors 19 Widescreen 546 units 22 Widescreen 558 units 24 Widescreen 116 units Total Quantity: 2,626 units
Divanti Group is a large supplier of used LCD Monitors. Our current monthly production is 35,000 units. Our LCD Monitors have been thoroughly tested to ensure they are able to be reused or remanufactured. Our production facility produces full loads of Grade A or Grade B LCDs. After our testing process, we sort and package by size of the screen (15", 17", 19" 4.3, 19" Wide, 20" Wide, 22" Wide, 23" Wide, 24" Wide). We typically sell our loads as mixed sizes, but we are also capable of selling custom loads with select sizes and quantities as inventory becomes available. Feel free to contact us for more information regarding our LCD products. Thank you.
Divanti Group is a large processor of used LCD/ LED Monitor panels. Our current monthly production is 35,000 panels. Our LCD/LED Panels have been thoroughly tested to ensure they are able to be reused or remanufactured. After our testing process, we sort and package by size of the screen (15", 17", 19"-21" Regular, 19"-21" Widescreen & 22" and Larger Widescreen). Our packaging department is able to package the panels in bulk boxes or for additional charges we can use custom packaging if required. We typically sell our loads as mixed size panels, but we are also capable of selling custom loads with select sizes and quantities as inventory becomes available. I attached some sample pictures as our LCD panels were tested for your reference. Feel free to contact us for more information regarding our LCD products. Thank you, Scott
This unit sense current for over current or earth fault protections, 1kg, height 105mm base 102 * 51mm
Key Specifications/Special Features Technical data Type JLW-180 Current range 5-80A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,locked-rotor,phase loss, Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
Key Specifications/Special Features Technical data Type DZB Rated voltage 220VAC,380VAC,50/60HZ Current range 1-10A,5-50A,10-100A,80-200A200-400A,400-600A,600-800A Proective functions locked-rotor,overcurrent, undervurrent,phase loss,phase unbalance,overvoltage,undervoltage, Optional functions RS-485 communication port4-20mA analog output indicators LED indicating voltage,current,operation status Output contacts 1C/O for trip1C/O for alert Contact capacity 3A 380VAC Dimensions(HÃ?WÃ?Dï¼? 118Ã?54Ã?135mm Mounting Screw fixing Features Integrative structure Built-in LED and keypad afford a precise,digital setting Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage Earth fault (should couple with ZCT) Fault recording RS-485 communication port (optional) 4-20 mA analog output (optional) 2 C/O output contacts, one for trip,one for alert Protective Functions Short-circuit Locked-rotor Overcurrent Undercurrent Phase loss Phase unbalance Overvoltage Undervoltage Typical Applications Pumps Fans Blowers Motors Compressors Approvals CE ROHS -
Accu-Chek test strips are essential components of blood glucose monitoring for individuals with diabetes. These strips are designed to work seamlessly with Accu-Chek blood glucose meters, enabling accurate and reliable measurement of blood sugar levels. The strips utilize advanced technology to require only a small blood sample, making the testing process more comfortable. With rapid and precise results, Accu-Chek test strips empower users to effectively manage their diabetes by providing valuable insights into their current glucose levels. This user-friendly and indispensable tool plays a crucial role in facilitating proactive health management for individuals living with diabetes.
Protects against Phase Loss, Phase Reversal & Phase Asymmetry Can be configured for 3 Phase 4 Wire or 1 Phase system Selectable Over Voltage / Under Voltage Trip level Selectable Time Delay LED Indications for Power and Fault conditions Voltage Sensing principle 1 C/O or 2 C/O Configuration Voltage Monitoring Series SM 500 83 Cat. No. Parameters 240 VAC (1 Phase & 3 Phase, 4 Wire) Frequency Power Consumption (Max.) 4 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) LED Indication Operating Temperature Storage Temperature Separate indications for Power ON, UV and OV O O -15 C To + 55 C O O -25 C To + 70 C Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Trip Settings Under Voltage Phase Loss Phase Sequence Phase Asymmetry Over Voltage 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 5 s 0.5 s to 15 min (Selectable) Time Delay ON Delay Trip Time (OFF Delay) Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 1 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Approx. Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale RoHS Compliant Humidity (Non Condensing) 95% (Rh) EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms Cat. No. Description MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
Key Specifications/Special Features Technical data Model JFY-5-3 Measuring circuit L N Rated voltage AC 220V,50/60Hz Monitoring functions overvolatege, undervoltage Overvoltage setting range AC200-300V adjustable Undervoltage setting range AC120-240V adjustable Recovery of overpressure 1-20 V adjustable Overvoltage Undervoltage Action time 0.1-60 s adjustable Indicators LCD indicating voltage,operationand fault status Output contacts 1 CO & 1 NO Contact capacity 6A ,250VAC Dimensions (H x W x D) 48Ã?48Ã?90mm Mounting DIN rail Features Powered by the measuring circuit Compatible with AC and DC supply Built-in LCD and keypad afford a precise,digital setting Compact modular 43mm housing Adjustable over- and undervoltage threshold Independent adjustable delay time for overvoltage, undervoltage Adjustable reset mode:automatic reset or manual reset 1 CO,1NO Protective Functions â?? Overvoltage Undervoltage Typical Applications Pumps Fans Air-conditioning system Blowers Motors Compressors Elevators Approvals CE ROHS -
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
Voltage Monitoring Series SM 501 86 Cat. No. Parameters MG53BH MG53BF MG63BH MG63BF 415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire) Frequency Power Consumption (Max.) 10 VA 5 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) Trip Settings Under Voltage Over Voltage Hysterisis 7 V (�± 2 V) of Trip Voltage Phase Loss Phase Sequence Phase Asymmetry Yes Yes LED Indication Storage Temperature Operating Temperature Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry O -15 C To + 55 C O O -25 C To + 70 C O Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 2 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale 2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms Humidity (Non Condensing) 95% (Rh) 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) Time 5 s Delay ON Delay Trip Time (OFF Delay) 10% (of ) Cat. No. Description MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O UV / OV UV / OV & SPP UV / OV & SPP EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms RoHS Compliant LED Indications for Power and Fault conditions Voltage Sensing Principle 2 C/O Configuration
Product nameï¼?3 Phase Relay Product Typeï¼?DPA53 Usageï¼?Protective Sizeï¼?Subminiature Protect Featureï¼?Sealed Contact Loadï¼?High Power Theoryï¼?Voltage Relay DPA53 series monitor for ultra-thin (17.5mm) rail mounting type, function: phase failure protection, phase sequence protection, voltage unbalance protection, adjustable set value undervoltage protection. It is suitable for the protection of the distribution system installed in the cabinet. I. Overview DPA53 series three-phase relays for three-phase or three-phase four-wire power supply for the monitor. This series of products measuring their own supply voltage, regenerative voltage, with phase sequence protection, lack of protection, undervoltage protection and other functions, N-type products with zero line disconnection protection. DPA53 series monitor for the ultra-thin (17.5mm) rail mounting type, suitable for installation of the cabinet to install the power distribution system protection, such as: distribution cabinet, distribution box, electric control box, machine tools and other equipment. Second, the input rated voltage: 200 ~ 240vAC ± 15% (line voltage) Model: DPA53CM23 320 ~ 480VAC ± 15% (line voltage) Model: DPA53CM48 115 ~ 138VAC ± 15% (phase voltage) Model: DPA53AM23N 220 ~ 277VAC ± 15% (phase voltage) Model: DPA53AM48N Phase sequence monitoring: When the three-phase power monitor power, such as the phase sequence is normal, the relay can pull. Phase loss monitoring: When the three-phase power monitor power, each phase power is normal, the relay can pull. Undervoltage protection: When the three-phase power supply line voltage is lower than the set value, then the relay release protection; when the voltage recovery, the relay back to work properly. N line disconnection protection: DPA53AM23N and DPA53AM48N is suitable for three-phase four-wire system power monitor, the two products in the N line when the relay release.
Rated power: 1-5KW Pure sine wave output Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc). Bult in MPPT 60A/80A solar charge controller Combining solar system, AC utility, and battery power source to supply continuous power Overload, short circuit and Deep discharge protection Cold start function Support USB, RS485 monitoring function WIFI remote monitoring (optional) Compatible to generator Support parallel operation up to 3 units (available for 3KW-5KW 48V) This is a multi-function inverter/charger, combining functions of inverter, MPPT 60A/80A solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Rated power: 1-5KW Pure sine wave output Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc). Bult in MPPT 60A/80A solar charge controller Combining solar system, AC utility, and battery power source to supply continuous power Overload, short circuit and Deep discharge protection Cold start function Support USB, RS485 monitoring function WIFI remote monitoring (optional) Compatible to generator This is a multi-function inverter/charger, combining functions of inverter, MPPT 60A/80A solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc). Built-in MPPT solar charge controller MAX PV Array Open Circuit Voltage: 450V Can provide the power to the load without battery Combining solar system, AC utility, and battery power source to supply continuous power Overload, short circuit and Deep discharge protection Cold start function Support USB, RS485 monitoring function Parallel operation with up to 3 units WIFI remote monitoring (optional) PV1800 PRO is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support in portable size. PV1800 PRO Series can run without battery. The Maximum PV array open circuit voltage can reach 450V and MPPT voltage is 150~430Vdc, which Can help customers make full use of solar energy.
On grid / Grid-tied Rated power: 5000W No. of MPPT: 2 Strings per MPPT: 1 Phase: Three phase Warranty: 10 years Dimension(W/H/D): 500*428*200mm Net weight: 21kgs LED display Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit. The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life. Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
On grid / Grid-tied Rated power: 6000W No. of MPPT: 2 Strings per MPPT: 1 Phase: Three phase Warranty: 10 years Dimension(W/H/D): 500*428*200mm Net weight: 21kgs LED display Protection devices: DC reverse polarity protection, output over current protection, output overvoltage protection-varistor, integrated DC switch, ground fault monitoring, integrated all-pole sensitive leakage current monitoring unit. The solar inverter takes full account of the needs of end customers, it is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner. With excellent performance at the same time, use LED as inverter status display, effectively improve product life. Using DSP digital control, could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.