This unit sense current for over current or earth fault protections,
1kg, height 105mm base 102 * 51mm
Key Specifications/Special Features Technical data Type JLW-180 Current range 5-80A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,locked-rotor,phase loss, Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
Key Specifications/Special Features Technical data Type DZB Rated voltage 220VAC,380VAC,50/60HZ Current range 1-10A,5-50A,10-100A,80-200A200-400A,400-600A,600-800A Proective functions locked-rotor,overcurrent, undervurrent,phase loss,phase unbalance,overvoltage,undervoltage, Optional functions RS-485 communication port4-20mA analog output indicators LED indicating voltage,current,operation status Output contacts 1C/O for trip1C/O for alert Contact capacity 3A 380VAC Dimensions(HÃ?WÃ?Dï¼? 118Ã?54Ã?135mm Mounting Screw fixing Features Integrative structure Built-in LED and keypad afford a precise,digital setting Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage Earth fault (should couple with ZCT) Fault recording RS-485 communication port (optional) 4-20 mA analog output (optional) 2 C/O output contacts, one for trip,one for alert Protective Functions Short-circuit Locked-rotor Overcurrent Undercurrent Phase loss Phase unbalance Overvoltage Undervoltage Typical Applications Pumps Fans Blowers Motors Compressors Approvals CE ROHS -
Protects against Phase Loss, Phase Reversal & Phase Asymmetry Can be configured for 3 Phase 4 Wire or 1 Phase system Selectable Over Voltage / Under Voltage Trip level Selectable Time Delay LED Indications for Power and Fault conditions Voltage Sensing principle 1 C/O or 2 C/O Configuration Voltage Monitoring Series SM 500 83 Cat. No. Parameters 240 VAC (1 Phase & 3 Phase, 4 Wire) Frequency Power Consumption (Max.) 4 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) LED Indication Operating Temperature Storage Temperature Separate indications for Power ON, UV and OV O O -15 C To + 55 C O O -25 C To + 70 C Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Trip Settings Under Voltage Phase Loss Phase Sequence Phase Asymmetry Over Voltage 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 5 s 0.5 s to 15 min (Selectable) Time Delay ON Delay Trip Time (OFF Delay) Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 1 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Approx. Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale RoHS Compliant Humidity (Non Condensing) 95% (Rh) EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms Cat. No. Description MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
Supplier: Timers, time switches, hour meters & counters, plc, voltage/current/frequency monitoring relays, elrs)
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
Voltage Monitoring Series SM 501 86 Cat. No. Parameters MG53BH MG53BF MG63BH MG63BF 415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire) Frequency Power Consumption (Max.) 10 VA 5 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) Trip Settings Under Voltage Over Voltage Hysterisis 7 V (�± 2 V) of Trip Voltage Phase Loss Phase Sequence Phase Asymmetry Yes Yes LED Indication Storage Temperature Operating Temperature Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry O -15 C To + 55 C O O -25 C To + 70 C O Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 2 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale 2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms Humidity (Non Condensing) 95% (Rh) 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) Time 5 s Delay ON Delay Trip Time (OFF Delay) 10% (of ) Cat. No. Description MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O UV / OV UV / OV & SPP UV / OV & SPP EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms RoHS Compliant LED Indications for Power and Fault conditions Voltage Sensing Principle 2 C/O Configuration
Product nameï¼?3 Phase Relay Product Typeï¼?DPA53 Usageï¼?Protective Sizeï¼?Subminiature Protect Featureï¼?Sealed Contact Loadï¼?High Power Theoryï¼?Voltage Relay DPA53 series monitor for ultra-thin (17.5mm) rail mounting type, function: phase failure protection, phase sequence protection, voltage unbalance protection, adjustable set value undervoltage protection. It is suitable for the protection of the distribution system installed in the cabinet. I. Overview DPA53 series three-phase relays for three-phase or three-phase four-wire power supply for the monitor. This series of products measuring their own supply voltage, regenerative voltage, with phase sequence protection, lack of protection, undervoltage protection and other functions, N-type products with zero line disconnection protection. DPA53 series monitor for the ultra-thin (17.5mm) rail mounting type, suitable for installation of the cabinet to install the power distribution system protection, such as: distribution cabinet, distribution box, electric control box, machine tools and other equipment. Second, the input rated voltage: 200 ~ 240vAC ± 15% (line voltage) Model: DPA53CM23 320 ~ 480VAC ± 15% (line voltage) Model: DPA53CM48 115 ~ 138VAC ± 15% (phase voltage) Model: DPA53AM23N 220 ~ 277VAC ± 15% (phase voltage) Model: DPA53AM48N Phase sequence monitoring: When the three-phase power monitor power, such as the phase sequence is normal, the relay can pull. Phase loss monitoring: When the three-phase power monitor power, each phase power is normal, the relay can pull. Undervoltage protection: When the three-phase power supply line voltage is lower than the set value, then the relay release protection; when the voltage recovery, the relay back to work properly. N line disconnection protection: DPA53AM23N and DPA53AM48N is suitable for three-phase four-wire system power monitor, the two products in the N line when the relay release.
1. Current tripping setting i!£g & display 2. Tripping time setting t!£g & display 3. Prealarm set-point setting al. & display 4. Function button 5. Setting & function selective button 6. Function setting button 7. Auxiliary supply presence 8. Prealarm display 9. Tripping display 10. Tripping test display 11. Reseting display 12. Tripping range:0.025~250a. 13. Tripping time: 0.02~500 second.
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1