Please click here to check who's online and chat with them.

Magmaa

Supplier From India
Feb-04-10
Supplier : Electrical & electronic automation products gic make timers , time switches, hour meters ,counters , water level controllers , plc, temperature controllers, street light control panels ,thermister relays , power supply, motor protection relays , rccb, mcb and other switchgear products

Services :
Established: 2003

Verification Status



Contact Details:
F-12, Rahi Park, 67/1B/23, Plot-13 Vidyanagar ,pune , Maharashtra India
Vidyanagar
Pune 411032
Maharashtra India


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Magmaa

Mar-18-21

Voltage Monitoring Relay Sm 501

$50.00
MOQ: Not Specified
Supplier From Pune, Maharashtra, India
 
Voltage Monitoring Series SM 501
86
Cat. No.
Parameters
MG53BH MG53BF MG63BH MG63BF
415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire)
Frequency
Power Consumption (Max.) 10 VA 5 VA
50/60 Hz
Supply Voltage ( )
105% to 125% (of )
55% to 95% (of )
Trip
Settings
Under Voltage
Over Voltage
Hysterisis 7 V (�± 2 V) of Trip Voltage
Phase Loss
Phase Sequence
Phase Asymmetry
Yes
Yes
LED Indication
Storage Temperature
Operating Temperature
Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry
O -15 C To + 55 C
O O -25 C To + 70 C
O
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
Output
Contact Rating
Electrical Life
Mechanical Life
Relay Output
5A @ 250 VAC / 28 VDC (Resistive)
5 1X10
6 3X10
2 C/O
Enclosure
Dimension (W x H x D) (in mm)
Weight (unpacked)
Mounting
Certification
Flame Retardant UL 94-V0
36 X 90 X 60
120 g
Base / DIN rail
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
ORDERING INFORMATION
Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale
2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms
Humidity (Non Condensing) 95% (Rh)
0.5 to 15 s (Selectable)
5 s
0.5 to 15 s (Selectable)
5 s 0.5 to 15 s (Selectable)
5 s
0.5 to 15 s (Selectable)
Time 5 s
Delay
ON Delay
Trip Time (OFF Delay)
10% (of )
Cat. No. Description
MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O
MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O
MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O
MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O
UV / OV
UV / OV & SPP
UV / OV & SPP
EMI / EMC
Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A
ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III
Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III
Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III
Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B
Environmental
Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03)
Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07)
Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g
Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms
Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms
RoHS Compliant
LED Indications for Power and Fault conditions
Voltage Sensing Principle
2 C/O Configuration
Mar-18-21

Voltage Monitoring Relay

$40.00
MOQ: Not Specified
Supplier From Pune, Maharashtra, India
 
Protects against Phase Loss, Phase Reversal & Phase Asymmetry
Can be configured for 3 Phase 4 Wire or 1 Phase system
Selectable Over Voltage / Under Voltage Trip level
Selectable Time Delay
LED Indications for Power and Fault conditions
Voltage Sensing principle
1 C/O or 2 C/O Configuration
Voltage Monitoring Series SM 500
83
Cat. No.
Parameters
240 VAC (1 Phase & 3 Phase, 4 Wire)
Frequency
Power Consumption (Max.) 4 VA
50/60 Hz
Supply Voltage ( )
105% to 125% (of )
55% to 95% (of )
LED Indication
Operating Temperature
Storage Temperature
Separate indications for Power ON, UV and OV
O O -15 C To + 55 C
O O -25 C To + 70 C
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
Trip
Settings
Under Voltage
Phase Loss
Phase Sequence
Phase Asymmetry
Over Voltage
0.5 to 15 s (Selectable)
5 s 0.5 to 15 s (Selectable)
5 s
5 s
0.5 s to 15 min (Selectable)
Time
Delay
ON Delay
Trip Time (OFF Delay)
Output
Contact Rating
Electrical Life
Mechanical Life
Relay Output
5A @ 250 VAC / 28 VDC (Resistive)
5 1X10
6 3X10
1 C/O
Enclosure
Dimension (W x H x D) (in mm)
Weight (unpacked) Approx.
Mounting
Certification
Flame Retardant UL 94-V0
36 X 90 X 60
120 g
Base / DIN rail
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
ORDERING INFORMATION
Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale
RoHS Compliant
Humidity (Non Condensing) 95% (Rh)
EMI / EMC
Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A
ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II
Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III
Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III
Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Environmental
Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03)
Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07)
Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g
Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms
Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms
Cat. No. Description
MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O
MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O
MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
GOLD Member
VERIFIED
Aug-10-23
Supplier From Khalapur, Maharashtra, India
 
CIRCULLATION FAN

Air cooling fans are used for maintaining good air circulation and temperature in poultry farms. Our 36 air circulating fans can be used for various applications, like poultry farms, industrial buildings etc., and providing high efficiency. These fans are available in both single phase and three phase motor option.
1.Grills are plastic coated and thick diameter wire gauge (2.5mm) is used, and the gap is maintained 15mm as per international quality standards to avoid human accidents and rate entering into the fan.
2. The blades are made of compounded plastic so less chances of bending and hence less breaking chances.
3. Motor is efficient and complete thermal protection and moisture proof.
4. The CFM of fan 13000 and minimum airflow of 8.5 meters/sec.
5. Minimum positive air throws of 50ft. When we say 50 Length in practically.
6. Easy installation &Zero Maintenance
Aug-05-20

Uv Led Sterilisation Wand

$15.00
MOQ: Not Specified
 
Model : uv light
Power : 2w
Power supply : usb 5v
Size: 357*40*35mm
Wave length : 275+395nm
Lamp beads : uv3535 6v 2w
Life span: 8000h
Color: black /white
Li-battery : 1800ma
Sterilization time : cm height 10-20 seconds
GOLD Member
Feb-25-19
Supplier From Tianjin, China
GOLD Member
Jun-13-22
Supplier From Dubai, United Arab Emirates
 
Plunger Type Pumps, Hydraulically Actuated Diaphragm Type Pumps, Mechanically Actuated Diaphragm Type Pumps, Solenoid, Operated Diaphragm Dosing Pumps, Complete Skid Mounted Dosing Systems, Chemical Process Pumps, Seal free Magnetic Drive Pumps, Progressive Pumps, Y Type Strainers, Pulsation dampners, etc.
GOLD Member
VERIFIED
Jan-26-21
Supplier From Singapore, Singapore, Singapore
 
PLCs have the central control role in various fields, including manufacturing and public systems, and in service fields. They can be used to construct optimal small and large-scale systems.
GOLD Member
VERIFIED
Oct-28-24
Supplier From Peshawar, KPK, Pakistan
GOLD Member
VERIFIED
Oct-19-20
Supplier From Seoul, South Korea (Republic Of Korea)

Verification Status