CP-S Synchroscope meter (analog synchroscope) shows the status of phase difference and frequency difference between two power generators or power systems. When the voltage and frequencies in between the power generator and network are consistent, the rotation of LED Roulette will be slowed down until the SYNC LED is on. Both systems can be synchronized and connect the generator to the power network.
MCM1000 series meter be designed for Industrial or commercial circuits sub-metering project. It's integrate 6pcs three phase energy meter(MCM1300) or 18pcs single phase energy meter(MCM1100). Metering operation processing by different MCU, provide high accuracy billing performerance, can beused as commerical & industry energy metering device. The compact design and non-display design can maximum reduce the hardware investment of electrical management or building energy metering project.
The 149-10A is a digital voltmeter that can measure high voltages up to a10kV AC and DC at high accuracy. Its high input impedance (1000M ohm) make it suitable for measurement of high impedance voltage circuits. Since it has a high accuracy despite its small size and light weight, it can also be easily used as a portable calibrator.
This electrical energy meter (kWh) phase DIN rail is a new generation of single-phase electronic energy meters, using techniques microelectronic circuits high integration (LSI), digital techniques and advanced techniques CMS. The meter meets the technical requirements of class 1, class 2 and IEC62052-11, IEC62053-21. It is used to measure active energy consumption accurately and directly from the ac phase (50/60 Hz).
M-4673 mini digital leakage current clamp meter features high reliability, safety, precision and compact design with 1mA resolution. AC/DC Current range of 100A; particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is T-RMS. Whole range overload protection, reliable measurement accuracy and unique design makes it an outstanding new generation electrician/electric power measurement instrument.
Clamp on AC current measurement up to 200 A. The CMP-200 digital clamp meter is designed for clamp measurements of AC leakage current. Clamp on AC Current CMP-200 Features high resolution (0,1 mA), three measuring ranges: 200 mA, 2 A, 200 A. display LCD 3�½ digit (max 1999), white LED backlight, sinternal diameter clamp approx. 30 mm (1,2â?³), DATA HOLD function, for holding measured values. MAX function, AUTO-OFF function, double molded casing. Available on back-order
CP-C moving coil panel meter with sprung toe bearing which is insensitive to external magnetic fields. The movable organs of the movements are stored in sprung jewels in order to protect them against crushes and vibrations. These instruments only measure DC current or DC voltage. By using core magnets of high quality the moving coil instruments have a almost linear scale course. Due to their low consumption they are especially suited for the application with shunts, impulse transmitters, thermo couples and for the connection to our electronic transducers. The instruments can be delivered for direct connection up to 100 A with a built-in shunt. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
CA-212 has been designed to ensure high accuracy in power factor regulation and excellent utilization of capacitor banks and relays in three phase 3 wire electrical grid common range for all network voltages from 100V to 440V system reactive power compensation front panel is equipped with a 3-digits 7 segments display to show the present value of power factor voltage and line current. Max 12 steps relay output for contactor easy commissioning optional LCD display screen(provide power monitor function and CT ratio setting). FEATURES I / U / COS measurement Three digital LED display Max 12 control steps (default 6 steps) Used in three-phase balance gird Self-powered from bus line
CB-212 is advance three phase 3 wire APFC display provide user-friendly interface and ease of access to parameters for manual setting built-in power analyzer allowing the instantaneous display of any electrical parameter (voltage current reactive power harmonics etc. With THD protection function not affected by the harmonics can protect capacitor from harmonic interference. Max 12 step control 5A/250V relay output or 12VDC output. Optional RS-485 communication port easy for user connect to PLC and build SCADA system. Higher measurement accuracy(0.5) and system stability it is cost effective ideal for OEMs and panel builders solution. FEATURES I / U / KW / KVAR / HZ / COS measurement and display 93*70 LCD display Anti-harmonic design Max 12 steps capacitor control
CD-212 is ready for operation with its preset functions immediately after installation without any modifications or adjustments. With smart switching control identifies the power of the connected capacitor stages and connects or disconnects them in an optimized manner as required by the actual mains conditions. This guarantees that optimum power factor correction is achieved with the minimum number of switching operations. Dynamic compensation response time less than20ms work with static contactor provide zero-crossing switching and harmonic protect function Suitable for welding steel rolling machinery cranes oil field pumping units wind power generation piling machines and other varies equipment with large instant impact system. With RS485 communication port can control extra 3 sets CD-212 build Max 48 step control. FEATURES Automatic detect electrical network system status, do not need special configuration Large size TFT LCD display, one screen can show more info than segment LCD screen Various automatic protection functions can make sure capacitor bank long term working With basic electrical parameter measurement and display (I / U / KW / KVAR / KVA / HZ / COS) Provide power quality statu display (Current & Voltage wavefrom and 2-31th Harmonic) Record past 4 days site Power factor trend, display in visualization graph