Protects against Phase Loss, Phase Reversal & Phase Asymmetry
Can be configured for 3 Phase 4 Wire or 1 Phase system
Selectable Over Voltage / Under Voltage Trip level
Selectable Time Delay
LED Indications for Power and Fault conditions
Voltage Sensing principle
1 C/O or 2 C/O Configuration
Voltage Monitoring Series SM 500
83
Cat. No.
Parameters
240 VAC (1 Phase & 3 Phase, 4 Wire)
Frequency
Power Consumption (Max.) 4 VA
50/60 Hz
Supply Voltage ( )
105% to 125% (of )
55% to 95% (of )
LED Indication
Operating Temperature
Storage Temperature
Separate indications for Power ON, UV and OV
O O -15 C To + 55 C
O O -25 C To + 70 C
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
Trip
Settings
Under Voltage
Phase Loss
Phase Sequence
Phase Asymmetry
Over Voltage
0.5 to 15 s (Selectable)
5 s 0.5 to 15 s (Selectable)
5 s
5 s
0.5 s to 15 min (Selectable)
Time
Delay
ON Delay
Trip Time (OFF Delay)
Output
Contact Rating
Electrical Life
Mechanical Life
Relay Output
5A @ 250 VAC / 28 VDC (Resistive)
5 1X10
6 3X10
1 C/O
Enclosure
Dimension (W x H x D) (in mm)
Weight (unpacked) Approx.
Mounting
Certification
Flame Retardant UL 94-V0
36 X 90 X 60
120 g
Base / DIN rail
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
ORDERING INFORMATION
Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale
RoHS Compliant
Humidity (Non Condensing) 95% (Rh)
EMI / EMC
Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A
ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II
Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III
Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III
Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Environmental
Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03)
Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07)
Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g
Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms
Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms
Cat. No. Description
MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O
MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O
MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
Voltage Monitoring Series SM 501 86 Cat. No. Parameters MG53BH MG53BF MG63BH MG63BF 415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire) Frequency Power Consumption (Max.) 10 VA 5 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) Trip Settings Under Voltage Over Voltage Hysterisis 7 V (�± 2 V) of Trip Voltage Phase Loss Phase Sequence Phase Asymmetry Yes Yes LED Indication Storage Temperature Operating Temperature Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry O -15 C To + 55 C O O -25 C To + 70 C O Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 2 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale 2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms Humidity (Non Condensing) 95% (Rh) 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) Time 5 s Delay ON Delay Trip Time (OFF Delay) 10% (of ) Cat. No. Description MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O UV / OV UV / OV & SPP UV / OV & SPP EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms RoHS Compliant LED Indications for Power and Fault conditions Voltage Sensing Principle 2 C/O Configuration
Product nameï¼?3 Phase Relay Product Typeï¼?DPA53 Usageï¼?Protective Sizeï¼?Subminiature Protect Featureï¼?Sealed Contact Loadï¼?High Power Theoryï¼?Voltage Relay DPA53 series monitor for ultra-thin (17.5mm) rail mounting type, function: phase failure protection, phase sequence protection, voltage unbalance protection, adjustable set value undervoltage protection. It is suitable for the protection of the distribution system installed in the cabinet. I. Overview DPA53 series three-phase relays for three-phase or three-phase four-wire power supply for the monitor. This series of products measuring their own supply voltage, regenerative voltage, with phase sequence protection, lack of protection, undervoltage protection and other functions, N-type products with zero line disconnection protection. DPA53 series monitor for the ultra-thin (17.5mm) rail mounting type, suitable for installation of the cabinet to install the power distribution system protection, such as: distribution cabinet, distribution box, electric control box, machine tools and other equipment. Second, the input rated voltage: 200 ~ 240vAC ± 15% (line voltage) Model: DPA53CM23 320 ~ 480VAC ± 15% (line voltage) Model: DPA53CM48 115 ~ 138VAC ± 15% (phase voltage) Model: DPA53AM23N 220 ~ 277VAC ± 15% (phase voltage) Model: DPA53AM48N Phase sequence monitoring: When the three-phase power monitor power, such as the phase sequence is normal, the relay can pull. Phase loss monitoring: When the three-phase power monitor power, each phase power is normal, the relay can pull. Undervoltage protection: When the three-phase power supply line voltage is lower than the set value, then the relay release protection; when the voltage recovery, the relay back to work properly. N line disconnection protection: DPA53AM23N and DPA53AM48N is suitable for three-phase four-wire system power monitor, the two products in the N line when the relay release.
1) under/over voltage monitoring relay 2) motor protection overload relay 3) electronic overload relay
Supplier: Micro controller based numeric protection, control & automation devices, single phase voltage monitoring relays, three phase voltage monitoring relays, multifunctional time delay relays, motor protection relays, automatic phase selectors, overcurrent relays & power limiters, temperature controllers, power quality analyzers and data loggers, programmable & astronomical timers, protocol converters & interface controllers for iot, food products powdered chutneys flaxseeds, rice, toordal, millets, electrical relays
Services: Distributors
Buyer: Pc's, laptops, computers, phones, desk phones, laptop chargers, it equipment, it components
This unit sense current for over current or earth fault protections, 1kg, height 105mm base 102 * 51mm
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
Key Specifications/Special Features Technical data Type JLW-180 Current range 5-80A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,locked-rotor,phase loss, Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
Key Specifications/Special Features Technical data Type DZB Rated voltage 220VAC,380VAC,50/60HZ Current range 1-10A,5-50A,10-100A,80-200A200-400A,400-600A,600-800A Proective functions locked-rotor,overcurrent, undervurrent,phase loss,phase unbalance,overvoltage,undervoltage, Optional functions RS-485 communication port4-20mA analog output indicators LED indicating voltage,current,operation status Output contacts 1C/O for trip1C/O for alert Contact capacity 3A 380VAC Dimensions(HÃ?WÃ?Dï¼? 118Ã?54Ã?135mm Mounting Screw fixing Features Integrative structure Built-in LED and keypad afford a precise,digital setting Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage Earth fault (should couple with ZCT) Fault recording RS-485 communication port (optional) 4-20 mA analog output (optional) 2 C/O output contacts, one for trip,one for alert Protective Functions Short-circuit Locked-rotor Overcurrent Undercurrent Phase loss Phase unbalance Overvoltage Undervoltage Typical Applications Pumps Fans Blowers Motors Compressors Approvals CE ROHS -
bms products are battery management systems developed for large-scale high-voltage battery energy storage systems. It adopts distributed architecture, modular design concept, high configurability, easy assembly, debugging and maintenance. It is suitable for various battery energy storage systems with dc voltage below 1000v. This product can be configured as a secondary architecture (bmu+cbms) for 10kwh-100kwh. Cooperate with industrial computer and battery stack management software to form a three-level architecture (bmu+cbms+gbms) for 50kwh-2mwh applications. In conjunction with the server and plant battery management system software, it can form a four-level architecture (bmu+cbms+gbms+bbms) for applications from 2mwh to 1000mwh to meet different project requirements the product has a complete and reliable operation and protection strategy to effectively extend the life of the battery pack. It comes with a variety of communication interfaces and can be directly or indirectly connected to third-party energy management systems.