Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel Product Features 1. 2 conventional input zones. 2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex. 3. The panel comes with a 2 amp power supply. 4.Dedicated alarm and trouble relays. 5.1 RS485 can be able to connect the other panel. 6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure. 7. Enclosure supports two 12V, 4Ah backup batteries. 8.The panel can be used independently or connect by RS 485. Specifications Primary AC 120VAC 50/60 Hz Power supply rating 240VAC 50/60 Hz Power supply rating 2 Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 2 Zones Alarm Zone 2 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Normal Quiescent Current (normal status)
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm System. The 2-wire 4001 is compatible with numens non-addressable devices The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming Facilitates out-of-box installation and rapid commissioning. 2, 4, 8, or 16 detection zones Up to 32 non-addressable devices per alarm zone circuit Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer 3 access levels Single-person test mode Day/night mode Manual activation of audio/visual alarm devices Supervised auxiliary dc 24 v output 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output 3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode Supports up to 7 repeater panels
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
1. General HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc. 1. Specifications a. Four Style B (Class B) Initiating Device Circuits (IDCs). b. All zones accept two-wire smoke detectors and any normally-open contact devices. c. One built-in Fire Fighting Ouput. d. 24-volt operation. e. Resettable four-wire smoke detector power @ 500 mA. f. Non-resettable power @ 500 mA. g. One-man walk-test programmable for silent or audible test. h. Disable/Enable control per IDC. i. Reverse polarity protection.
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
The mini 2 zone panel HS-CK1002 have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault. 2. Specifications Item No. HS-CK1002 HS-CK1004 HS-CK1008 HS-CK1016 Zones 2 4 8 16 Sound output 1 1 2 4 AC power 220VAC/50Hz 220VAC/50Hz 220VAC/50Hz 220VAC/50Hz Battery Sealed lead-acid only Total DC24V system power 3.0 amps Max current per NAC 1.25amps Max battery charging capability 18AH Cabinet weight(net/gross) 3.5/4kg w/o battery 6.0/6.6kg w/o battery 6.0/6.6kg w/o battery 6.0/6.6kg w/o battery 3. Features our Style B (Class B) Initiating Device Circuits (IDCs). One Master Panel also has two zones, each zone can connect max.25 conventional detectors. One slave Panel has two zones, each zone can connect max.25 conventional detectors. The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
Smoke, heat, gas, co detectors alarm, conventional, addressable fire alarm control panel, sounder.
2 wire 9V-28VDC powered conbined Smoke detector and Heat Detector electronic conbined fire alarm HS-FT103 1pc/blister box(103*103*55mm,155g) ;60pcs/carton box They work perfectly with all conventional intelligent fire control panels Advanced MCU Expert Algorithm Software. Easy installation and maintenance Durable sensor head, no need for replacement
Power Supply: AC 240V 50/60Hz Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery Charging Voltage: DC26.4V Below 450mA Trickle Charging Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA Loop Resistance: Below 50+ back and forth Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A) Terminal Resistor: 10k+ Number of indicators: 1 time the number of panel circuits Number of Local Alarm: 1 time the number of panel circuits. Number of circuit & Dimension: 1L/2L/4L/5L/8L (330x280x120mm) 12L/16L(400x300x120mm) 24L(495x300x120mm).
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
HS-DG812 Battery Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity. Our standard battery is 6F22, lithium battery is optional. Key Specifications/Special Features Power Source: 9V Battery (included). Audio Alarm: 85dB/3m Temperature Range: 0 to 40 Humidity Range: 5%-95% relative humidity(RH) Sensor: Photoelectric Size: diameter 106mm in diameter x32mm depth Interconnects: No Easy to install with mounting base included Suitable for any room Low battery signal Test button for simple testing
HS-SB106 Manual Call Point, Designed for Conventional Fire Alarm Systems and Security Alarm system for reporting fire or emergency condition by pressing its breakable glass. The manual call point can be test by a test key without breaking the glass. 2. Specifications Name 6" Alarm Bell Manual call point Product category 2 wire, Compatible with all existing conventional fire alarm control panel Item No. HS-JL188-6 HS-SB106 Operating voltage DC24V DC24V Alarm current 70mA @ DC24V 30mA @ DC24V Alarm sound intensity Minimum 95dB N/A Dimension Diameter 155mm, height 45mm 88mm*88mm*52mm Weight 650g 172g Features Easy to install bracket Break glass 3. Features a. Available for flush or surface mounting b. Plastic film on glass c. Test key inserted from side d. Open circuit with series resistor e. Suitable for the majority of conventional fire alarm systems