Power Supply: AC 240V 50/60Hz Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery Charging Voltage: DC26.4V Below 450mA Trickle Charging Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA Loop Resistance: Below 50+ back and forth Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A) Terminal Resistor: 10k+ Number of indicators: 1 time the number of panel circuits Number of Local Alarm: 1 time the number of panel circuits. Number of circuit & Dimension: 1L/2L/4L/5L/8L (330x280x120mm) 12L/16L(400x300x120mm) 24L(495x300x120mm).
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
Mn/300/100 fire alarm control panel Overview The mn300 is a new type of analog fire alarm control panel which has 100 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses). It complies with the provisions of both fire alarm control units (gb4717-2005) and automatic control system for fire protection (gb16806-2006). Features 1 the intelligent detectors and the intelligent modules have internal microprocessors to realize digital filtering and auto-compensation functions; the data collection is true and reliable; the mn300 control panel can carry out data processing based on fuzzy control theory and modern fire alarm theory to fundamentally avoid missing alarms and to reduce false alarms, so as to improve reliability. 2 the detectors have a sensitivity setup function and can adjust the alarm sensitivity according to the specific environment and their influences. 3 the detecting bus and the control bus share a two-wire structure and have non-polarity and fully mixed coding of the detectors and modules, and the intelligent detectors and the intelligent modules can be directly connected to them, which greatly simplifies the system wiring, engineering installation and circuit maintenance. 4 the system uses an ac-dc master-standby power supply system which will automatically change between the master and standby power supplies in the event of a power failure of either of the two power supplies to ensure uninterrupted operation of the system. 5 the mn300 can be connected to a special mini-printer to realize real-time printing. 6 the mn300 can be connected to floor fire display panels to display fire alarms by standard rs-485 7 the mn300 can be connected to ten multi-line linkage control/monitoring points to control and monitor important equipment. 8 the mn300 is equipped with eight bus manual control points, which makes it very easy for the user to control related equipment.
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected To non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that Require special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log