The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).