AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm System. The 2-wire 4001 is compatible with numens non-addressable devices The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming Facilitates out-of-box installation and rapid commissioning. 2, 4, 8, or 16 detection zones Up to 32 non-addressable devices per alarm zone circuit Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer 3 access levels Single-person test mode Day/night mode Manual activation of audio/visual alarm devices Supervised auxiliary dc 24 v output 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output 3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode Supports up to 7 repeater panels
Name : Weed control mat/Ground cover/ 1. Weight 2oz/sm - 14oz/sm or 60gsm-150gsm 2. Width 1.6' -20' or 0.5m-6m 3. Roll Length 16', 33', 65', or 5m,10m,20m,25m,50m,100m or as required 4. Color Black,Green,Black-green or as required 5. Weave 8*8,10*10,11*11,12*12,12*16 6. Material 100% PP material 7. UV resistance 3-5 years 8. Sample Avaliable 9. Delivery time About 20 days 10. Min order No limit 11.Terms of payment 1.TT or LC 12. Supply capacity 500 tons per month 13. Packing In rolls with paper core inside and polybag outside or in Carton or as your request 14. Quantity 1x20ft container can load about 11 tons 1x40'HC can load about 26 tons 15.Export market Australia,Canada,Argentina,USA,The Middle East,Europe market ,Japan and so on.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)."
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel Product Features 1. 2 conventional input zones. 2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex. 3. The panel comes with a 2 amp power supply. 4.Dedicated alarm and trouble relays. 5.1 RS485 can be able to connect the other panel. 6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure. 7. Enclosure supports two 12V, 4Ah backup batteries. 8.The panel can be used independently or connect by RS 485. Specifications Primary AC 120VAC 50/60 Hz Power supply rating 240VAC 50/60 Hz Power supply rating 2 Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 2 Zones Alarm Zone 2 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Normal Quiescent Current (normal status)
Refractory bricks, high alumina bricks, acid proof bricks, tiles and castables, all mortars and fire clay, low cement castables, insulating castables, conventional dense refractory bricks, insulation bricks, cold face, hot face insulation bricks, hot face insulation bricks, acid resistant bricks/components, membranes, acid resistant cement, construction chemicals, class 1 ar tiles and bricks 38mm and 75mm, 4457 vitrified ar tiles with 0% water absorption, 20mm & 25m, primer, mastics, pot. silicate cement, coerce cement, furnace based cement, crushed refractory boiler bed material, acid resistant tiles, acid resistant brick fireclay type, acid resistant brick red shale type, bitumen primer, epoxy resin & hardner, furan powder and syrup solution,.
Power Supply: AC 240V 50/60Hz Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery Charging Voltage: DC26.4V Below 450mA Trickle Charging Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA Loop Resistance: Below 50+ back and forth Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A) Terminal Resistor: 10k+ Number of indicators: 1 time the number of panel circuits Number of Local Alarm: 1 time the number of panel circuits. Number of circuit & Dimension: 1L/2L/4L/5L/8L (330x280x120mm) 12L/16L(400x300x120mm) 24L(495x300x120mm).
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be Connected to non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require Special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log
meatball making machine meatball forming machine meatball process line/production line with frequency control and no-frequency control . The meatball forming machine adopts continuous output meatball system, which has high production efficiency, and is equipped with knives and shapers of different caliber, which can be replaced at will according to the requirements of users. The machine is mainly used to produce chicken balls, fish balls, shrimp balls, pork balls, beef balls, mutton balls, donkey balls, vegetable balls, seafood balls and other products. The main equipment of meatball production line includes meat planer, mincing machine, chopping and mixing machine, stuffing mixing machine, meatball machine, forming water tank, frying production equipment, etc. The machine is small in size, light in weight, low in noise, beautiful and generous, durable, easy to operate and maintain, efficient and energy-saving. The meat (FISH) balls produced are of good quality, smooth appearance, good roundness and uniform size. The frame body is made of 3mm thick stainless steel by bending and welding, which is solid for internal use. Wear resistant brass is used inside and outside the outlet. Capacity 50-500pcs/min ,meatball diameters : 16-40mm, above 40mm big size meatball can customized mould .
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Ceiling access panels, access panel fittings, pipes and fittings, industrial fasteners, fire rated access panels, metal doors.
Magnesia Bricks Description Magnesia Bricks are alkaline refractory materials. These products have over 90% magnesium oxide content and adopt periclase as the principal crystalline phase. Magnesia Bricks can be divided into two categories of Burnt Magnesia Bricks and Chemical Bonded Magnesite Brick. They have excellent performance of superior high temperature mechanical strength and volume stability. Magnesia Bricks can service in the high temperature of 1750.. They are ideal products for glass furnace application. Magnesia Bricks Features: It is a kind of alkaline refractory product with periclase as main phase magnesite-alumina spinel clinker as basic material. the product has such characteristics as good temperature vibration, good strength and volume stability in high temperature. Magnesia Bricks Application Basic open-hearth furnace for steelmaking Electric furnace bottom and wall Permanent lining of oxygen converter Non-ferrous metal metallurgy furnace Hyperthermia tunnel kiln Lining of rotary cement kiln Heating furnace bottom and wall Regenerative chamber of glass furnace Magnesia Bricks Properties High Refractoriness Good alkaline slag erosion resistance High apparent initial softening temperature Good thermal conductivity High thermal expansion Magnesia Bricks Manufacturing Process Burnt Magnesia Bricks are manufactured with magnesite clinker as the raw material and fired in the high temperature of 1550~1600 after smashing, burdening, mulling and molding. High-purity products can be fired in the temperature that over 1750. Chemical bonded magnesite brick is produced with certain chemical bonding through mixing, molding and drying.