Main features: 1). Qualified and ideal laboratory centrifuge; 2). Adopts advanced microprocessor system for accurately controlling speed, time, temperature and RCF value; 3). Driven by free-maintenance frequency conversion motor for high speed accuracy; 4). CFC free refrigerated system with double circuits of heating/cooling for high temp. accuracy; 5). Digital display; 6). 30 programs can be edited and stored; 7). 10 grades of acc/dec speed for option; 8). Automatic identification system of rotor for avoiding over-speed; 9). Protections of over-speed, over-temperature, imbalance and automatic diagnosis system. Standard wood case or waterproof carton.
ESW-750 Lab Horizontal Bead Mill Description: ESW-750 Lab Horizontal Bead Mill is a kind of wet-grinding machine suitable for continuous or cyclical process. The machine applies to materials with various viscosity and can get ideal particle size in shorter time, more efficiently. It is easy to start with low energy consumption rate and high grinding effect. Features: 1. Adopt German Burgamnn Mechanical seal with compact structure and liquid recycle pump which can ensure the seal can work normally for a long time 2. Adopt dynamic trapezoid fence booms discharge to solve conventional problem of slowly discharge, stuck grinding medium etc. 3. The inner tank uses special compound stainless steel which is completely penetrated after the heat treatment so that ensure the hardness is equal to the hardness before be thoroughly grinded. Therefore, the ddurability can be ensured and metal pollution can be avoided 4. Adopt spiral cooling system, taking most of the heat of the grinding tank. 5. Finely dispering and grinding materials with different viscosity from micro to nanometer 6. Suitable for continuous or cyclical process. Technical Parameters Model: ESW -750 Lab Horizontal Mill Voltage: 380v/50Hz 3PH ( can be customized) Motor: 750W Mechanical SealingL Germany Burgmann mechanical seal, it can bear pressure higher than 10kgs Material of Chamber: High chrome steel after heat treatment, its hardness can reach HRC62-68 Grinding Material: Special high wear-resistant alloy steel Discharging Way: dynamic trapezoid fence booms discharge Inlet&outlet pipe: Diameter for inlet pipe and outlet pipe is G1/2 separately Cooling Way: Multiply Bellows Volume of Grinding Tank: (ml)400ml Speed(rpm): 0~8000 Flow of Cooling Water: 80L/H. Dimension450X210X360 Weight(kgs)30.
For general laboratory use for various experiments. Made of polished brass, each mass has a standard keyhole slot to retain on hanger. Each mass and hanger is stamped with its own value
Weight - 25 grams Width - 2.5 – 3.0 mm Thickness - 0.3 – 0.5 mm Length - 55 – 60 feet Appearance - In the form of a reel.
Blue and red litmus paper pkg. Of 100 leaves.
Nickel-plated brass tube with a free moving air regulator and serrated gas inlet nickel-plated brass tube, 9mm O.D. Base made of stamped steel sheet. Base dia 80mm and overall height 140mm approx. Powder coated or stove enamel finish. NATURAL GAS, 11mm dia tube L.P.GAS, 11mm dia tube NATURAL GAS, 13mm dia tube L.P.GAS, 13mm dia tube COAL GAS, 13mm dia tube.
Made from seasoned wood with both edges divided in mm and numbered every 10mm, nicely polished. Horizontal and vertical reading.
1. Blood collection tube, 2. Serum tube , pt tube, 3. Heparin tube, 4. No additive tube. Quantity:1200 pcs Measurement:48, 38, 20.
Faith-1000 is a random access automatic biochemistry analyzer. It adapts 120pcs cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical index of patient. Main specifications: Test speed: 200 tests/hour Assay types:end-point assay, rate assay, fixed-point assay... Assay items: 45 items once time Cuvette: 120 reaction bottles; light path length: 6mm Total reaction volume: 180ul minimum Sample volume: 2 to 50 microliters Reagent volume: r1 25ul-300ul; r2 10ul-150ul Reaction time: about 10 minutes Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm quality control: 6 types per test item Dimensions analyzer: 958mm*700mm*(500+600)1100mm.
Main specifications: 1. Test speed: 300 tests/hour 2. Assay types: end-point assay, rate assay, fixed-point assay 3. Cuvette: 120 reaction bottles; optical length:6mm 4. Sample tray: 60 non-fixed positions for various samples 5. Reagent tray: 45 positions for reagent bottles 6. Assay items: 45 items once time 7. Cuvette: 120 reaction bottles; light path length: 6mm 8. Compatible reagent: supports different reagents from different countries 9. Total reaction volume: 180ul minimum 10. Sample volume: 2 to 50 micro liters 11. Reagent volume: r1 25ul-300ul; r2 10ul-150ul 12. Reaction time: about 10 minutes 13. Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm 14. Quality control: 6 types per test item 15. Calibration methods: linear and non-linear 16. Wavelength: 340, 405, 510, 546, 578, 600, 660, 700... 17. System function: 24 hour non-stop working, Support stat tests; 2-wavelength photometer 18. Lamp: 12v35w, 8 photodiodes.
Hemagen Analyst Benchtop Blood Chemistry Analyzer . This unit was manufacturer refurbished on July 2002 and never used since. It comes with Manuals, Neutral Rotor, Printer Paper, and Replacement Fuses. Get profile, panel or single test results in 10 minutes for glucose, BUN, creatinine, BUN/creatinine ratio, uric acid, cholesterol, triglyceride, GOT, total bilirubin, alkaline phosphatase, GPT, GGT, calcium, total protein, and amylase. All reagents are dry and pre-packaged to minimize operator error and to increase productivity. No interference from fibrin clots saves rotors, time and rerun costs. Sample requirement is just 90 ul of plasma or serum allowing you to test even the smallest patients. Interfaces with most Veterinary Practice Management Software programs. This unit is completely reconditioned and recertified.
New and unused. Comes with configuration manager software 1.0, power supply, temperature verification cartridge, 2 system verification cartridges(30 sec. And 300 sec.) Features: Performs rapid and accurate tests within minutes Two level QC lockout Preprogrammed valid operator IDs and notes Store up to 400 QC results and 400 patient results Offers liquid and electronic quality controls Customizable programming options with Configuration Manager software Test Menu: ACT-LR: Low Range Activated Clotting TIme ACT+: Activated Clotting Time Plus PT: Prothrombin Time Citrate PT: Citrate Prothrombin Time APTT: Activated Partial Thromboplastin Time Citrate APTT: Citrated Partial Thromboplastin Time.
Specifications : 1- Load Capacity: 0- 1000kgs. 2- Maximum distance between grips: 700mm 3- Speed: Variable speed 4- Microprocessor based load indicator: Accuracy of ± 0.05% of load indicated & Resolution Of 100grams. 5- Extension meter: Least count of 1 mm through Proximity/ Encoder switch. 6- Over load excess elongation protection provided. 7- Newton or Kg. Can be selected. 8- A pair of grips provided to hold the samples up to 6 mm thickness. 9- Floor Standing Model. 10- Paint: Powder Coating. 11- Power: 440V AC, 3Phase, 50 Hz. Standard.
Specifications: 1- Pressure range: 0 ¡V 100kg/cm2„XNumber of stations: Three. (All for Long And Short Term) 2- Pressure Accuracy: Electromagnetic, hydro pneumatic pump(mercury make) keeps the accumulator charged at desired pressure, which in turn will ensure the smooth flow of static pressure. 3- Pressure input: Compressed air up to 7 kg/cm2 4- Pressure out put: Through hydro pneumatic pump. Ratio 1:25 5- Pressure control & Time Control: Three nos. of Digital pressure Controller Range 0.00 to 99.99 Bar. & Timer Range up to 999.9/9999 hours. 6- Failure detection: Through three nos. of Time totalizes. 7- Power requirement: 230 Volts 50HZ. 8- Paints: Powder coating. 9- RS 232 interface with WINDOW based software to conduct test and keep record of data with graph in PC. Standard.
Specifications: 1- Microprocessor based Controller with range up to 1000 deg C and Accuracy of ± 1 deg C. 2- Silica quartz combustion tube and boat. 3- Heating load of 2kv. 4- Ceramic furnace with nichrome heating element. 5- Paint: Powder Coated. 6- Power: 230V AC. Standard.
Tetracycline residue rapid test device. 40 pcs/kit.
Detection of e. Coli o157 article qualitative detection of colloidal gold feces, food, water and other samples of e. Coli o157. The degree of color is proportional to the sample bacteria. Enrichment effect well. Can be used to treat samples in rapid screening, positive samples can be isolated bacteria, reduce the workload. Steps: 1. Will be placed on the detection of clean, dry working platform. 2. Provided with the kit with clean straw or from the pipette to take samples or enrichment sample 2 drops, drops added to the test sample by adding end section (detection section white side), start timing; 3. 2-15 minutes of observation, 15 minutes after the results do not count. [Results judge] negative: a red line appears, which appears in the control line position of a red line; positive: two red lines appear, that in the test line and control line positions are there red line; invalid: no red line appears that the test line and control line in the position not appear red. [Treatment of samples to be tested] 1. Direct detection: direct detection of water will be. 2. By bacteria detection (1) stool samples: the samples of the inoculated immediately take 1 gram of 9ml of mec broth, 37 constant temperature shaking culture 6h. (2) food samples: the 25 g samples of ground, and immediately inoculated in 225ml of mec broth, 37 constant temperature shaking culture 9h. (3) water samples: water samples will be 400ml immediately inoculated in 5 times concentrated mec 100ml in broth, 37 constant temperature shaking culture 16-20h. 3. Proposed use of enrichment broth was added 20mg / l novobiocin the ec modified broth. [Interpretation of the results] 1. Enrichment after negative results may be judged as negative. 2. Or by direct detection of bacteria have positive results, the pathogen can be isolated. 3. Negative result does not have a precise meaning. [storage] 4-30 , cool dark dry place.
Intended use: Toxoplasma igg/igm rapid test is a rapid immunochromatographic test for the simultaneous detection of igm and igg antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma igg/igm rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of igm anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit igg. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied: 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30 c. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
1. Intended use: The salbutamol residue rapid test card is a rapid, one step test for the qualitative detection of salbutamol in meat samples. The whole time of assay is only approx. 15~25min. 2. Summary: Salbutamol belongs to the group of G-agonists. It can promote animalí»s fat metabollism, and accelerate the growth of animal. However, this is prohibitted. Except for its lipolytic and anabolic effect, salbutamol is used as antiasthmatic and tocolytic agent which has a slacken effect on non-striated musculature. It can remain in animalí»s body and may lead to strong effect to human. If for worse, it may threaten peopleí»s life. Salbutamol is prohibitted for using in most countries. The salbutamol residue rapid test card is a rapid test to qualitatively detect the presence of salbutamol in specimen at the sensitivity of 58g/kg. The major advantage of the one step test device is that the result can be observed easily . 3. Principle: The principle is the antigen-antibody reaction. The one step test device is a competitive immunoassay of which the detector reagent consists colloidal gold particles that is coated with affinity purified anti-salbutamol antibodies. The capture reagent in the assay is salbutamol-protein conjugate, which is immobilised on the membrane of the test device. The specimen migrates over the membrane. The more analyte in the sample, the more effectively it will compete with the salbutamol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent.. If salbutamol in the specimen is above 58g/kg, it will prevent the binding of the detector reagent with the salbutamol immobilised on the membrane, resulting in positive.
Uses: It is used when liquid heating is needed in industry, agriculture, health and medicine, scientific research and college labs etc. Characteristics: 1. Enclosed big size Ceramic Hot Plate with characteristics of flame protection and durability. 2. Heating and stirring can proceed simultaneously. 3. Heating power and stirring speed is stepless adjusted. The Digital type has the more function as follows: a.Can control the srirring clockwise and anticlockwise b.With two sensors can show different setting number c.Can show the setting temperature,hot plate surface temperature,setting speed and actual speed at the same time. d.Can show the setting temperature,tested liquid temperature,setting speed and actual speed at the same time 300, 190, 126 400, 240, 220.