Specifications :
1- Load Capacity: 0- 1000kgs.
2- Maximum distance between grips: 700mm
3- Speed: Variable speed
4- Microprocessor based load indicator: Accuracy of ± 0.05% of load indicated & Resolution Of 100grams.
5- Extension meter: Least count of 1 mm through Proximity/ Encoder switch.
6- Over load excess elongation protection provided.
7- Newton or Kg. Can be selected.
8- A pair of grips provided to hold the samples up to 6 mm thickness.
9- Floor Standing Model.
10- Paint: Powder Coating.
11- Power: 440V AC, 3Phase, 50 Hz.
Standard.
Specifications: 1- Pressure range: 0 ¡V 100kg/cm2„XNumber of stations: Three. (All for Long And Short Term) 2- Pressure Accuracy: Electromagnetic, hydro pneumatic pump(mercury make) keeps the accumulator charged at desired pressure, which in turn will ensure the smooth flow of static pressure. 3- Pressure input: Compressed air up to 7 kg/cm2 4- Pressure out put: Through hydro pneumatic pump. Ratio 1:25 5- Pressure control & Time Control: Three nos. of Digital pressure Controller Range 0.00 to 99.99 Bar. & Timer Range up to 999.9/9999 hours. 6- Failure detection: Through three nos. of Time totalizes. 7- Power requirement: 230 Volts 50HZ. 8- Paints: Powder coating. 9- RS 232 interface with WINDOW based software to conduct test and keep record of data with graph in PC. Standard.
Supplier: Climate Test Machines, Tensile Test Machines, Battery Test Machines, Plastic Test Machines, Salt Spray Test Machines
Supplier: Packaging testing instruments, packages testing instruments, material testing machines, plastic films testing machines
Supplier: Environmental Chamber, Face Mask Testing Instruments, Packaging Testing Instruments, Pipe Testing Instruments, Colour Testing Instruments, Industrial Chillers, Plastic And Rubber Testing Instruments, Universal Testing Machines, Bench Top Hardness Tester, Portable Hardness Tester, Video Measuring System, Profile Projector, Metallographic Equipment, Industrial Machineries, Plastic Recycling Systems, Spout Insert And Sealing Machine, Cooling And Heating Systems
Tensile testing machine.
Description: The test apparatus suitable for measuring the smoke emitted by wires and cables burning under specific conditions, such as horizontal combustion of some cables or optical cables, are used as a means of comparing different cables or optical cables or judging whether they meet specific requirements under flaming or flameless combustion conditions. . It meets the test standard of GB/T17651.1-2-19.98 "Determination of smoke density in combustion of cables and optical cables under specific conditions". Performance parameters: Optical measuring device: The light source and receiver should be placed in the middle position outside the sealing window on the opposite wall of the combustion chamber. Measurement range: 0-100%. That is, the optical device will be energized before the blank test. Calibration of transmittance: calibration with transmittance of 25%, 50% and 75%. Standard Fire Source: Standard Fire Source: 1.0L+0.01L Alcohol Plate; Ethanol: 90% +/- 1%; Methanol: 4% +/- 1%; water: 6% +/- 1%. Control system: adopt DETECION control procedure and ZWH 4500 acquisition control card. Operating interface: WINDOWSXP operating interface, DETECION control program, perfect security mechanism. During the test, the measurement results are displayed in real time and the perfect curve is plotted dynamically.
Intended use: Toxoplasma IGG/IGM rapid test is a rapid immunochromatographic test for the simultaneous detection of IGM and IGG antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma IGG/IGM rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) A burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) A nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of IGM anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit IGG. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied : 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30pc. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
Capacity (n): 10/20/30/50/100 Accuracy: grade 1 Measuring range: 0.25 / 0.5 / 0.75 / 1.0 Relative error: ínía1.0% Effective tensile stroke: 750 / 580mm Speed adjusting range: 10 - 250mm/min-2 / 5 - 150mm/min-2 Power supply: 380vac
Max. Capacity: 1000kn / 2000kn Rated pressure: 40mpa Relative error: ía2% Piston stroke: 40mm Measuring range: 0 - 500kn %26amp; 0 - 1000kn / 0 - 800kn %26amp; 0-2000kn Pressure platen size: 230mm x 290mm Distance between platens: 320mm / 330mm Power supply: 220vac 750w