Main specifications: 1. Test speed: 300 tests/hour 2. Assay types: end-point assay, rate assay, fixed-point assay 3. Cuvette: 120 reaction bottles; optical length:6mm 4. Sample tray: 60 non-fixed positions for various samples 5. Reagent tray: 45 positions for reagent bottles 6. Assay items: 45 items once time 7. Cuvette: 120 reaction bottles; light path length: 6mm 8. Compatible reagent: supports different reagents from different countries 9. Total reaction volume: 180ul minimum 10. Sample volume: 2 to 50 micro liters 11. Reagent volume: r1 25ul-300ul; r2 10ul-150ul 12. Reaction time: about 10 minutes 13. Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm 14. Quality control: 6 types per test item 15. Calibration methods: linear and non-linear 16. Wavelength: 340, 405, 510, 546, 578, 600, 660, 700... 17. System function: 24 hour non-stop working, Support stat tests; 2-wavelength photometer 18. Lamp: 12v35w, 8 photodiodes.
Faith-1000 is a random access automatic biochemistry analyzer. It adapts 120pcs cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical index of patient. Main specifications: Test speed: 200 tests/hour Assay types:end-point assay, rate assay, fixed-point assay... Assay items: 45 items once time Cuvette: 120 reaction bottles; light path length: 6mm Total reaction volume: 180ul minimum Sample volume: 2 to 50 microliters Reagent volume: r1 25ul-300ul; r2 10ul-150ul Reaction time: about 10 minutes Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm quality control: 6 types per test item Dimensions analyzer: 958mm*700mm*(500+600)1100mm Loading sample system The loading apparatus(syringe) is imported from german microsyring which is assured the accuracy of minimum sample.
Faith-1000 is a random access automatic biochemistry analyzer. It adapts 120pcs cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical index of patient. Main specifications: Test speed: 200 tests/hour Assay types:end-point assay, rate assay, fixed-point assay... Assay items: 45 items once time Cuvette: 120 reaction bottles; light path length: 6mm Total reaction volume: 180ul minimum Sample volume: 2 to 50 microliters Reagent volume: r1 25ul-300ul; r2 10ul-150ul Reaction time: about 10 minutes Wavelength: 340, 405, 510, 546, 578, 630, 660, 700nm quality control: 6 types per test item Dimensions analyzer: 958mm*700mm*(500+600)1100mm.
Biochemical analyzer Faith-1020 is a random access automatic biochemistry analyzer. It adapts 120pcs cuvette as reaction and test container and has the feature of suitable test speed, not across-pollutions and low consumable, opening reagent. It is used for testing the biochemical guideline of patient. Test speed 160 tests/hour(invariable speed) methodologyend-point, kinetic, fixed time; sample tray24 non-fixed positions for various samples Reagent tray24 positions for reagent bottles Cuvette 120 reaction bottles;optical length:6mm Reaction volume:180-500ul Compatible reagent:supports different reagents from different countries Sample volume2 to 50ul Reagent volumer1 25-300ul; r2 10-150ul Reaction volume180-500ul Reaction timeabout 10 minutes Calibration methodslinear and non-linear +wavelength:340, 405, 510, 546, 578, 600, 660, 700... System function24 hour non-stop working, support stattests;2-wavelength photometer Lamp12v35w, 8 photodiodes Power250w Size 680-420-360(mm)
CRYSTAL is a fully automatic biochemistry analyzer which can do 300 test per hour. it has 60 sample position and 45 reagent positions. the accuracy is as per the European standard. THE SERVICE ENGINEERS ARE IN BANGALORE TO GIVE AFTER SALES SUPPORT. THE COMPANY PROVIDES ONE YEAR OF WARRANTY.
Fully automatic chemistry analyzer Discrete automatic, random stat function Online test items: at most 26 testing items 18 sample positions, 26 reagent positions with refrigrated function Throughtput: 200 tests/hour 60 pcs reaction cuvettes Wavelength: 300-800nm, 9 wavelengths 7-step automatic washing, automatic cuvette dry function Easy to operate Compact construction and light weight Dimension:540x420x320mm Net weight:23kgs
1. Fully automated, discrete, random access . 10. Perfect function of quality control management is convenient for users to manage the clinical test result. 11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data. 12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe. 1150*980*1350
Performance: 1. Reasonable software, programmable biochemical test menu, 200 test programmes can be saved. 2. 1000 patients test data can be saved. 3. Clock CMOS chip inserted. 4. Hermetic solid-state optical system, low contamination of dust and dampness,long life time of hard membrane filters. 5. Back spectro photometry, 8 hard membrane filter, separate signal process circuit for each wavelength, filters select completed electronically,no mechanical movement. 6. Titanium alloy flow cell with small capacity and minimize cross-contamination. 7. Back-light LCD monitor and display character and curve simultaneously 8. Self-test program, test error
. 20 incubating positions. ¡. Membrane keyboard. ¢. Bulid-in thermal printer. £. Real-time graph display