Dish antennas On specification by client
Vasthi Instruments are global leaders in manufacturing of Dew point transmitter and have been supplying instruments to customers worldwide, Our multidisciplinary team of scientists, physicians, engineers, and regulatory consultants with decades of global experience brings you the quintessential mechanism that provides complete safety accuracy and durability. Vasthi Instruments was formed with visionary thinking and innovative ideas resulting in innovative products and solutions. We enhance our product quality by the continuous process of research and development. We have WIDE range of models to suite various site conditions and processes
Wireless Interface RF Modules can be interfaced with R5.0V1 weighing scale PSBs to Make your weighing scale machine wireless .It can Transmit wireless data to a distance of about 100 feet.You can even receive the wireless weight data to your PC for wireless data acquisition .We will provide you free technology support for you to build a complete wireless weighing system .
We have available following Ships spareparts for Sale: Siemens u' trasoric level transmitter
We have available following Ships spare parts for Sale: Product-Sensotec Model-811-FMG/1110-02 Made in USA
We have available following ships spares for Sale: Product- Electronic Diff Pressure Transmitter Maker-Yokogava Hokushin Model-Y/13A Part no-6411EA688 616
Key Features: 1.Rugged, wear & tear resistant sensor design 2.High corrosion resistant 3.Rinsable pressure chambers 4.Suitable for aggressive media 5.Unaffected by vibration, radiation, dirt etc Key Specifications: 1.Measuring range: 0 ~ 100 mbar to 0 ~ 25 bar 2.Measuring principle: fluid filled membrance / diaphragm system with inductive pickup system 3.Maximum static pressure: 100 bar 4.Measuring span: can be set steplessly from 20% ~ 100% of the full scale 5.Measuring start: can be set steplessly from 0% ~ 100% of the measuring range when the characteristic curve falls (switchable) can be set steplessly from 100% ~ 0% of the full scale 6.Temperature or measuring media: -10 °C to +70 °C 7.Ambient temperature: -10 °C to +70 °C 8.Electromagnetic compatibility: DIN EN 61000-6-2 (interference resistance), DIN EN 61000-6-4 (emitted interference) 9.Output: analog 0/4-20mA, with characteristic curve of linear, rising or falling (switchable) 10.Measuring membrane: Nickle-Beryllium / Duratherm 11.Fluid Filling: Baysilone oil PD 5 12.Measuring chamber, separating membrane: Chromium nickel steel 1.4571 (AISI 316Ti) 13.Protection: IP as per EN 60529 / IEC 529 14.Product qualification: in compliance with KTA 3505 Application areas: 1.Water and effluent treatment plants, and other filtration applications 2.Filter condition monitoring 3.Flow measurement of steam and hot water, using differential pressure flow sensors, in 4.remote heating systems 5.Pump Control dependent on differential pressure in block unit heating power stations Application areas: 1.Nuclear power plants 2.Manufacturing and chemical plants 3.Marine, shipping application 4.Onshore and offshore area 5.Petrochemical, solvent industry 6.Sewage, effluent treatment plants
Key Features: 1.Configurable measuring range 2.Configurable parameters via LCD Display, keypad 3.Integrated operating pressure measurement up to 40 bar 4.Suitable for non-corrosive gaseous media and vapour 5.Corrosion resistant field housing 6.Oil and grease free for oxygen applications Key Specifications: 1.Measuring range: 0 ~ 160 mbar to 0 ~ 2.5 bar 2.Maximum static pressure: 40 bar 3.Design: Differential pressure measurement, with or without integrated operating pressure measurement (25 bar or 40 bar) 4.Electrical output: differential pressure & operating pressure â?? 4-20mA 2-wire connection 5.Maximum pressure load: one-sided overpressure-proof up to the rated pressure of the measuring system, resistance to under-pressure on the (+) and (-) side 6.Linearity: < 1% Full scale 7.Ambient temperature: -20 �°C to +70 �°C 8.Admissible media temperature: -20 �°C to +70 �°C 9.Characteristic curve: linear 10.Pressure connection: inner thread G 1/4 cutting ring screw connection for 8 or 10 mm pipe 11.Measuring membrane: 1.4305 NiBe for differential; Al2O3 for operating pressure 12.Protection: IP65 as per EN 60529, with integrated ceramic sensor Application areas: 1.Filter condition monitoring 2.Flow measurement and control 3.Pump Control Application areas: 1.Nuclear power plants 2.Manufacturing and chemical plants 3.Marine, shipping application 4.Onshore and offshore area 5.Petrochemical, solvent industry 6.Sewage, effluent treatment plants
Key Features: 1.High accuracy 2.Robust and compact design 3.Overload protection 4.High vibration resistant 5.Minimum hysteresis Key Specifications: 1.Measuring range: -1.0 ~ 0.0 bar to -1.0 ~ -24.0 bar (max. pressure: 3 ~ 80 bar) 0.0 ~ 1.6 bar to 0 ~ 60.0 bar (max. pressure: 5 ~ 200 bar) 2.Linearity: < 1% full scale 3.Hysteresis: < 0.5% full scale 4.Permissible ambient temperature: 0° C ~ +60° C 5.Permissible medium temperature: 0° C ~ +85° C 6.Protection class: IP65 acc. to DIN EN 60529 7.Materials (media contact): chrome nickel steel 1.4305, ceramics, AL2O3, gaskets 8.Material (housing): Chrome nickel steel 1.4305 9.Nominal power supply: 24 VDC / AC 10.Output: linear, 4~2-mA / 0~10 V, 2/3-wire Industrial areas: 1.Nuclear power plants 2.Thermal / gas fired power plants 3.Chemical & manufacturing industries 4.Semiconductor plants
Key features: 1.Direct measurement, without transfer fluid 2.High vibration resistance 3.High accuracy 4.High overpressure safety 5.Minimum hysteresis Key specifications: 1.Measuring range: 0 ~ 1.6 bar to 0 ~ 60 bar (overpressure safety: 3.2 bar ~ 120 bar) -1.0 ~ 0.0 bar to -1.0 ~ 15 bar (overpressure safety: 2 bar ~ 32 bar) 2.Linearity: < 1% full scale 3.Hysteresis: < 0.5% full scale 4.Permissible ambient temperature: 0, ° c ~ 60, ° c 5.Permissible media temperature: 0, ° c ~ 100, ° c 6.Nominal power supply: 24v dc 7.Output signal: 0~20ma / 4~20ma / 0~10v, 3-wire 8.Ingress protection: ip65 acc. To din en 60529 9.Temperature drift, zero: 0.4% full scale / 10k 10.Temperature drift, range: 0.05% full scale / 10k 11.Electrical connection: connection plug m16 x 1.5 acc. To din en 175301-803 12.Material, medium contact: aisi 316l (1.4404), gasket: viton 13.Material, body: aisi 304 (1.4305) Industrial areas: 1.Chemical industries 2.Machine and plant engineering 3.Process engineering 4.Manufacturing industries 5.Glass and silicon industries
Key features: Two independent differential pressure sensors Robust design, over-pressure protected Selectable pressure unit Signal output with possibility of spreading and inverting characteristic curve with any offset (optional) Characteristic conversion of output via 3, .30 entries tablets) Fully programmable via pc based eu03 module Large led display Key specifications: 1.Two independent differential pressure sensor. 2.Measuring range (of each sensor): 0 ~ 4.0 mbar up to 0 ~ 100 mbar; , ± 2.5 mbar to , ± 60.0 mbar 3.Maximum static operating pressure: 50 mbar to 500 mbar 4.Maximum safe pressure: 150 mbar to 1500 mbar 5.Straight line deviation error (max): 1.0% full scale 6.Pressure connection: g 1/8 female threads with optional cutting ring fittings for 6 or 8 mm tube 7.Operating ambient & media temperature: -10, ° c to +70, ° c 8.Protection class: ip65 per din en 60529 9.Electrical output: 4-20ma or 0-10v, 3 , ?? wire 10.Power supply: 24 v dc/ ac 11.Switching contacts: 2 sets of programmable voltage free contacts: no or nc 12.Display: 3 1/2 digit led 13.Electrical connections: two round shell multi-pin connector sockets (m12, male) 14.Material, housing: polyamide pa 6.6 15.Materials, media contact: silicon, pvc, aluminum, brass Application areas: 1.Roll band filter monitoring 2.Vacuum system monitoring 3.Chimney draught measurement 4.Flow and control pressure monitoring 5.Surface coating system 6.Pump monitoring and control 7.Compressor monitoring and control Industrial areas: 1.Air conditioning and ventilation systems 2.Auditorium, office, conference rooms 3.Hvac and ventilation application 4.Environment monitoring 5.Clean room and laboratory rooms
EJX110A EMS4G-912EN/FF1 Yokogawa Pressure Transmitter EJX110A 3600 Psi Condition : New
ABB Make TTH200 Head Mounted Temperature Transmitter Model:TTH200.Y0.H.BS-.EM..GHA...D3.SF.Z2.C07.M5 Communication Protocol:HART, programmable, output signal 4 ... 20 mA Display Options:LCD indicator type AS Mounting Options:Snap-on fixing set for 35 mm rail acc. EN 60175 (incl. fixing screws)
Agasthya 2013 Series Dual Pass Transmissometer Dust Monitor BI 7000 Path Length 1 20 m flange to flange separation Measuring Range 0 -1000 mg/m3 user selectable Units of measurement mg/m3, mg/Nm3, % Opacity Accuracy 1% relative to the maximum range Resolution 1mg/m3 Drift with Temperature 1% over any 20C in the operating range Operating Wavelength510 540 nm Green LED Stack Temperature 300 C Power Supply 110 230 VAC Air Supply 5 10 m3/hr Flow & 500 mbar Pressure. Must exceed maximum stack pressure. Air Inlet Connection 1 BSP threaded Output 4 20 mA Analog output Digital Interface RS 485, MODBUS protocol Mounting Wall Electronic Unit Enclosure Rating IP 65 Tx & Rx Junction Box Rating IP 65 Cable 2 core screened cable of 0.5mm2,8 meters between Tx & Rx 6 core screened cable of 0.5mm2,25 meters between Rx & Electronic Unit Ambient Temperature -20 to 50 C Operating Humidity 5 95% Direct measurement in exhaust flue gas flow In situ Dual Pass for accurate reading Unit programmable in mg/m3, mg/Nm3, % Opacity RS 485, MODBUS protocol Rugged design with no moving parts so low maintenance Green LED source for long lifetime stability IP65 rating Enclosure The best price performance on the market designed with user requirements foremost in mind
The Dew Point Transmitter from Instruments is the best measurement tool for continuous dew point measurement. The dew guidance estimation is accurate down to -60 C Td (76 F Td). Dew point Transmitter Instruments' Dew Point Transmitter is the ideal measurement device for continuous dew point measurement. It has a precise dew point estimation down to -60 C Td (-76 F Td). The Dew Point Transmitter utilizes microprocessor-based circuitry to convert sensor signals using psychometric equations. The device is assembled in a rugged handheld IP-65 body with quick-disconnect tubing couplings. The device also has an internal sensor manifold for accurate dew point measurement and uses an RS485 interface (Modbus RTU). The device is equipped with a dedicated input to maintain line pressure. The powerful metal encasing (Aluminum or Treated steel) ensures extreme durability of the device. FEATURES : Analog output 4-20 mA for dew point Condensation insensitive Fast adjustment time Pressure resistant up to 350 bar(special version) RS485 RTU interface The higher resolution of the sensor signal history graphical data Sensor diagnosis is on-site with a mobile device. Readable via Modbus: Pressure dew point Temperature Rel. humidity Moisture content V / V