We offer high quality I-Sys Weighoing Indicator for our valuable clients I-Sys weighing indicator offered by us supports upto 8Loadcells and accepts 20mV loadcell input our I-Sys weighing indicator comes with Isolated RS232for reliable communication & digitsl filter options for stable measurement in weigh bridge appliocation .I-Sys weighing indicator offered by us has also tank weighing optional display of actual weight upon power failure & resumption .
To configure the machine, connect the power supply. Now press TARE key(K4) and with the TARE key(K4) pressed power on the Machine (switch connected to the Main Load Vs Displacement PCB). It shows Now use the INCREMENT key(K2) & SHIFT key(K3) to enter the Password given to you & then press the ENTER key(K1). If your Password is wrong it will display Sorry
Supports Multiple Rs232 Data String. Configurable Baud Rate & Ascii Data String . Supports Continuous Data Mode & Request Mode. Optically Isolated Rs232 For Reliable Communication . Suitable For Weigh-Bridge & Industrial Weighing Applications.
Our Optically Isolated RS232 card convert TTL logic of the UART (controller ) to RS 232 (PC)via .Optical isolators.This isolator provides very reliable communication in noisy area sometimes running of counts happens when a weighing scale board is connected to pc via simple MAX232 chip .
This STM85 microcontroller based control card can be used to switch ON & OFF 17relays via serial communication (RS232 or UART TTL) .It can also read the status of 8-digit inputs .The relay output status & digital input status is continuously sent out as RS232 data string .It operates in 9600BPS,8-N-1 mode .This control card can be controlled via weighing scale PCB or via PC.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Product Details: Model/Type PP 6800 Printing Technology Direct Thermal Usage/Application Receipt Printing Color Black/Grey Style Black And White Speed Printing 150mm per second high Paper Width 80mm/58mm Power 220V We are prominent manufacturer & suppliers of high-quality USB Thermal Receipt Printers. We are engaged in offering USB Thermal Receipt Printer to our clients. Additional Information: Item Code: Posiflex-PP-6800
Supplier: Steel structures, high voltage & low voltage, cables/accessories, electrical & instrumentation products, industrial pumps, electric motors and accessories, industrial valves, gear drives, vfd drives, soft starters, transmission couplings, ht and lt control panels, mcc panels, fasteners & welding consumables, scaffolding material, chemicals, irrigation spares.
Services: Engineering procurement company/merchant exporter