Key Features:
1.Rugged, wear & tear resistant sensor design
2.High corrosion resistant
3.Rinsable pressure chambers
4.Suitable for aggressive media
5.Unaffected by vibration, radiation, dirt etc
Key Specifications:
1.Measuring range: 0 ~ 100 mbar to 0 ~ 25 bar
2.Measuring principle: fluid filled membrance / diaphragm system with inductive pickup system
3.Maximum static pressure: 100 bar
4.Measuring span: can be set steplessly from 20% ~ 100% of the full scale
5.Measuring start: can be set steplessly from 0% ~ 100% of the measuring range when the characteristic curve falls (switchable) can be set steplessly from 100% ~ 0% of the full scale
6.Temperature or measuring media: -10 °C to +70 °C
7.Ambient temperature: -10 °C to +70 °C
8.Electromagnetic compatibility: DIN EN 61000-6-2 (interference resistance), DIN EN 61000-6-4 (emitted interference)
9.Output: analog 0/4-20mA, with characteristic curve of linear, rising or falling (switchable)
10.Measuring membrane: Nickle-Beryllium / Duratherm
11.Fluid Filling: Baysilone oil PD 5
12.Measuring chamber, separating membrane: Chromium nickel steel 1.4571 (AISI 316Ti)
13.Protection: IP as per EN 60529 / IEC 529
14.Product qualification: in compliance with KTA 3505
Application areas:
1.Water and effluent treatment plants, and other filtration applications
2.Filter condition monitoring
3.Flow measurement of steam and hot water, using differential pressure flow sensors, in 4.remote heating systems
5.Pump Control dependent on differential pressure in block unit heating power stations
Application areas:
1.Nuclear power plants
2.Manufacturing and chemical plants
3.Marine, shipping application
4.Onshore and offshore area
5.Petrochemical, solvent industry
6.Sewage, effluent treatment plants
Technical Specifications MTK 6580 Quad Core 1GB, 8GB EMMC 7 inch Capacitive Touch Screen Display 80mm built-in Thermal & Lablel Printer Dual SIM Cards, Support Micro TF Card Including NFC and IC card (optional) Charging Dock Stand Black, White and Red Colors Can be used as Standalone Cash Register Product Name HDD-A7 Material Plastic and iron Function Android/Linux POS System, Cash Register Package Standard Export CartonSize: L 32cm* W 17cm* H 15cm Weight: 1.383 kg
Key Features: 1.Configurable measuring range 2.Configurable parameters via LCD Display, keypad 3.Integrated operating pressure measurement up to 40 bar 4.Suitable for non-corrosive gaseous media and vapour 5.Corrosion resistant field housing 6.Oil and grease free for oxygen applications Key Specifications: 1.Measuring range: 0 ~ 160 mbar to 0 ~ 2.5 bar 2.Maximum static pressure: 40 bar 3.Design: Differential pressure measurement, with or without integrated operating pressure measurement (25 bar or 40 bar) 4.Electrical output: differential pressure & operating pressure â?? 4-20mA 2-wire connection 5.Maximum pressure load: one-sided overpressure-proof up to the rated pressure of the measuring system, resistance to under-pressure on the (+) and (-) side 6.Linearity: < 1% Full scale 7.Ambient temperature: -20 �°C to +70 �°C 8.Admissible media temperature: -20 �°C to +70 �°C 9.Characteristic curve: linear 10.Pressure connection: inner thread G 1/4 cutting ring screw connection for 8 or 10 mm pipe 11.Measuring membrane: 1.4305 NiBe for differential; Al2O3 for operating pressure 12.Protection: IP65 as per EN 60529, with integrated ceramic sensor Application areas: 1.Filter condition monitoring 2.Flow measurement and control 3.Pump Control Application areas: 1.Nuclear power plants 2.Manufacturing and chemical plants 3.Marine, shipping application 4.Onshore and offshore area 5.Petrochemical, solvent industry 6.Sewage, effluent treatment plants
Key features: Two independent differential pressure sensors Robust design, over-pressure protected Selectable pressure unit Signal output with possibility of spreading and inverting characteristic curve with any offset (optional) Characteristic conversion of output via 3, .30 entries tablets) Fully programmable via pc based eu03 module Large led display Key specifications: 1.Two independent differential pressure sensor. 2.Measuring range (of each sensor): 0 ~ 4.0 mbar up to 0 ~ 100 mbar; , ± 2.5 mbar to , ± 60.0 mbar 3.Maximum static operating pressure: 50 mbar to 500 mbar 4.Maximum safe pressure: 150 mbar to 1500 mbar 5.Straight line deviation error (max): 1.0% full scale 6.Pressure connection: g 1/8 female threads with optional cutting ring fittings for 6 or 8 mm tube 7.Operating ambient & media temperature: -10, ° c to +70, ° c 8.Protection class: ip65 per din en 60529 9.Electrical output: 4-20ma or 0-10v, 3 , ?? wire 10.Power supply: 24 v dc/ ac 11.Switching contacts: 2 sets of programmable voltage free contacts: no or nc 12.Display: 3 1/2 digit led 13.Electrical connections: two round shell multi-pin connector sockets (m12, male) 14.Material, housing: polyamide pa 6.6 15.Materials, media contact: silicon, pvc, aluminum, brass Application areas: 1.Roll band filter monitoring 2.Vacuum system monitoring 3.Chimney draught measurement 4.Flow and control pressure monitoring 5.Surface coating system 6.Pump monitoring and control 7.Compressor monitoring and control Industrial areas: 1.Air conditioning and ventilation systems 2.Auditorium, office, conference rooms 3.Hvac and ventilation application 4.Environment monitoring 5.Clean room and laboratory rooms
Key features: 1.Direct measurement, without transfer fluid 2.High vibration resistance 3.High accuracy 4.High overpressure safety 5.Minimum hysteresis Key specifications: 1.Measuring range: 0 ~ 1.6 bar to 0 ~ 60 bar (overpressure safety: 3.2 bar ~ 120 bar) -1.0 ~ 0.0 bar to -1.0 ~ 15 bar (overpressure safety: 2 bar ~ 32 bar) 2.Linearity: < 1% full scale 3.Hysteresis: < 0.5% full scale 4.Permissible ambient temperature: 0, ° c ~ 60, ° c 5.Permissible media temperature: 0, ° c ~ 100, ° c 6.Nominal power supply: 24v dc 7.Output signal: 0~20ma / 4~20ma / 0~10v, 3-wire 8.Ingress protection: ip65 acc. To din en 60529 9.Temperature drift, zero: 0.4% full scale / 10k 10.Temperature drift, range: 0.05% full scale / 10k 11.Electrical connection: connection plug m16 x 1.5 acc. To din en 175301-803 12.Material, medium contact: aisi 316l (1.4404), gasket: viton 13.Material, body: aisi 304 (1.4305) Industrial areas: 1.Chemical industries 2.Machine and plant engineering 3.Process engineering 4.Manufacturing industries 5.Glass and silicon industries
Differential Transmitter In All Brand Emerson , Rosemount , Honeyweel , F+h , E+h Etc
Long battery life. By stand-by mode, battery lasts 1000h. Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m. Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area. bug detectors can not detect sleeping transmitter. (RCS-50) Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission) Available channels... Uhf-a, uhf-b Mic effective range... 15m from circle point. (RCS-50) Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended) Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 11h (6lr61, continuous transmission) Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
General Description The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media. Technical Index Measuring medium: liquid, gas, steam Pressure range: -0.1MPA~0~60MPA Accuracy grade: ±0.2%FS, ±0.5%FS Stability: â?¤0.2%FS/year Temperature drift: â?¤0.02%FS/(range 0~70) Environment temperature: -20+85 Storage temperature: -20+85 Output signal: 4-20mA or 1-5VDC Supply voltage: 12-40VDC Allow overload: two times the quota voltage Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6 Wetware material: 316 stainless steel and 1Gr18Ni9Ti Shell material: die casting alloy aluminum,surface epoxy spraying Pressure interface: M20X1.5 Weight: ordinary 0.75kg, with on-site instructions 1kg Structure Type x1 Connection x2x31 x4 The link mode and output signal of the compact tranmitter are as follows: Two-wire system: 1 Positive power supply 2 Negative power supply 3 Empty 4 Shell Three wire system: 1 positive power supply 2 Negative power supply (Negative sharing with signals) 3 Signal+ 4 Shell x5 The connection mode of aviation plug transmitter is as follows: Two-wire system(direct outlet type) 1 Red wire connection positive power supply 2 Black wire connection negative power supply Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months.