From 25KVA to 5000KVA power and from 6,3 KV to 36 KV voltage features, Trans-el produces Oil type, hermetic transformers or transformers with an oil expansion tank, Indoor and outdoor power and distribution Transformers.
GANZ current transformers meet the highest international quality standards with more than 50 years of experience in industry.
Wise - transformer Wise trnsformers are built according to all ce rules , are ferro-magnetic built , balast type , is a classe i product . 20 units pack , eacch transformer 0, 800gr , palets of 1500 transformers
Used transformers
Used transformers
We sell current transformers. Please contact me for quotation.
From 25KVA to 5000KVA power and from 6,3 KV to 36 KV voltage features, Trans-el produces Oil type, hermetic transformers or transformers with an oil expansion tank, Indoor and outdoor power and distribution Transformers
Gas ignition transformers from 2 outlets to 6 outlets. For gas cookers, gas ovens. Potted with epoxy resin.
Dry-type transformer.Power range is:100-20000-30000 kVA. Durable to instantenous temperature changes and also to short-circuit. 100% protected from moisture.It cant get fired has an ability to extinguish the fire. Does not contain any Halogen or Nitrogen.Price changes due to power range.
Toroidal magnetic cores are made of a Fe-based thin (20 microns) nanocrystalline ribbon and have low loss, high induction of saturation, high operating temperature (up to 150 C), high magnetic permeability. Magnetic cores have a negative temperature coefficient of losses that provides stabilization mode transformer temperature. Application in power high- frequency transformers push-pull,bicyclic SMPS, DC-DC converters, audiotransformers. High permeability provides good electromagnetic connection of windings and low leakage inductance values. HIGHLIGHTS OF THE MATERIAL: Induction amplitude, Bm (25 C) 1,2 T Induction amplitude, Bm (90 C) 1,1 T Curie temperature, Tc 570 C Magnetostriction less than 0,5 x10 ^ -6 Magnetic Permeability (100 kHz) - up to 20,000
Neon Lamp Transformers from 6KV up to 12KV. Potted under vacuum with epoxy resin. Protections: Output open circuit, overload, output short circuit, earth-leakage, input over voltage.
Co-based amorphous core in plastic container 1. high permeability 2.Thickness (1820 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. Common-mode filter chokes, current transformers, including for precise electronic electricity meters, protective cutout, High Frequency power transformers in SMPS, audio transformers, etc. 5.D from 4-32mm Ribbon wound magnetic core is placed into hard protective container of glass-polyamide and mechanically fixed with silicone sealant. Co-based amorphous ribbon wound magnetic core is placed into hard protective container of glass-polyamide and mechanically fixed with silicone sealant.Size veries:outer D =4-32mm.The container has rounded edges and is designed for direct winding of a thick wire. The container provides reliable mechanical protection and preservation of amorphous material's properties. All materials comply with UL94V-1 / 0. 1. High permeability 2.Thickness (1820 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. KEY FEATURES OF THE AMORPHOUS MATERIAL: Induction amplitude, Bm (25C) 0.59 T Induction amplitude, Bm (90C) 0.50 T Curie temperature, Tc 220C Operating temperature range -60C ... 100C Magnetostriction less than 0.110^-6 Typical permeability (10 kHz) - 120 000 Typical permeability (100 kHz) - 35 000
Co-based amorphous core in plastic container 1. high permeability 2.Thickness (18-20 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. Application: Common-mode filter chokes, current transformers, including for precise electronic electricity meters, protective cutout, High Frequency power transformers in SMPS, audio transformers, etc. KEY FEATURES OF THE AMORPHOUS MATERIAL: Induction amplitude, Bm(25C) 0.62 T Induction amplitude, Bm(90C) 0.54 T Squareness ratio Br/Bm (@ 100 kHz, 80 A/m) at least 0.90 Curie temperature, Tc 225C Operating temperature range -60C ... +100C Magnetostriction less than 0.110^-6
250 kVA OIL TYPE DISTRIBUTION TRANSFORMER Measuring winding resistances Measurinq rotation ratios Inspecting polarity or connection group Measuring short circuit and load losses Measuring idle losses and current Induced voltage test Applied voltage test Measuring insulation resistances Transformers, for which mounting, drying and oil filling works are completed, are subjected to below mentioned routine and typical tests as specified by TS 267 standard. Oil breakdown stress control Loss gap (tq) measurement (DOUBLE test) Measuring painting thickness Temperature increase (heating test) Measuring of audible noise level Boiler lifetime test (For Hermetic Transformers) Mechanical strength test against short circuits This test is conducted in CESI/ITALIA, IPH/GERMANY test laboratories.) Except for the mechanical strength test against short circuits, all typical tests are conducted in the laboratories of our company,
• ability to detect every angle through 360° motion sensor technology • smooth lighting through sanded glass • emergency lighting feature when power cut • perfect detection thanks to digital technology • adjustable time delay, lux settings • easy mounting on the surface • emergency lighting intensity 16 lux / 29 lumen. Euro pallet
Current transformers.
Electric transformers.
Electric transformers.
Electric transformers.
Dc current transformer.