Dry-type transformer.Power range is:100-20000-30000 kVA.
Durable to instantenous temperature changes and also to short-circuit.
100% protected from moisture.It cant get fired has an ability to extinguish the fire.
Does not contain any Halogen or Nitrogen.Price changes due to power range.
2450Kva threee phase dry type transformer Our products got certificate of ISO9001,ISO14001 and OHSAS18001. And 18 low voltage products get national certificate of CCC. Also our products get quality testing report from China Quality Certification Center(CQC). Our customers include urban distribution network, power station, transformer substation, oil, chemical, railway and big construction companies. And products export to America, Brazil, Peru, Kenya, Ethiopia, India, Myanmar, Vietnam etc. We sincerely welcome all friends from domestic and overseas to come to cooperate and develop together.
Introduce: This product has advantages of low no-load losses, oil-free, flame self-extinguishing, moisture, crack-resistant and maintenance free. Now the entire place which used the ordinary dry type transformer can be replaced by amorphous one. It can be used for high-rise buildings, commercial centers, subways, airports, railway stations, factories and power plants, especially suitable for flammable, explosive high-demand places. Performance: - low-energy saving - high corrosion resistance - strong ability to withstand short circuit - low noise - low temperature and long service life Application area: - altitudeâ?¤1000m - environmental temperature -25+40 - indoor use
Our dry-type transformers, also known as "dry transformers," are designed to provide efficient and reliable electrical power distribution. These transformers use air or resin as the cooling medium instead of traditional oil. This design minimizes the risk of environmental contamination and allows for safe operation in various settings. Key features of our dry-type transformers include: 1. **Safety and Environmental Friendliness:** As there is no oil involved, the risk of fire and environmental impact is significantly reduced. This makes them a safer and more environmentally friendly option. 2. **Versatility:** Dry-type transformers are suitable for a wide range of applications, including industrial facilities, commercial buildings, and residential areas. They can be customized to meet specific voltage and power requirements. 3. **Low Maintenance:** These transformers generally require lower maintenance compared to oil-filled transformers, resulting in cost savings over their lifecycle. 4. **Compact Design:** The absence of oil allows for a more compact and lightweight design, making them easier to install and suitable for locations with space constraints. 5. **Efficiency:** Our dry-type transformers are designed for high efficiency, ensuring minimal energy loss during power distribution. Whether for upgrading existing infrastructure or implementing new projects, our dry-type transformers are engineered to deliver optimal performance, reliability, and safety in diverse electrical applications.
SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformerï¼?cast resin dry transformerï¼?step up dry transformer Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low operating costs. Product Features Function Characteristics: Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low operating costs. The enclosure can be of Good moisture resistance, transformer can be put into operation without pre-drying under 100% humidity in the normal operation. Low loss, light weight and small volume, low noise, good dissipation of heat, it can be 150% rated load operation under forced air cooling conditions. Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of transformers. High reliability. The results of checking for the products that has been put into operation show that the reliability index has reached the international advanced level. Structural Characteristics: Foil Coil: Adopting the entire section of copper foil, together with the F-class turn insulation, low voltage winding is wound by the special low-voltage foil winding machine. The foil coil resolves problems such as large short-circuit stress, ampere turn unbalance, poor heat dissipation, existing the winding spiral angle and unsteady manual welding quality due to low voltage and large current coil. At the same time, the end of winding is treated with cast resin, solidification to make shape, moisture-proof and anti-fouling, the lead for copper bar is welded by argon arc welding automatically. Temperature Control Device: the transformer adopts BWDK series of signal thermometer. The temperature components are embedded in the upper half of the low-voltage coil, can detect and display the temperature of separate phase coil automatically and continuously, also have the functions of over-temperature alarm and trip. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Three-phase transformers are used to convert the available 3-phase mains voltage into any load voltage. To cater for the wide range of application areas involved,these transformers are essentially available in the same kinds of designs as the single-phase transformers, e.g. Three-phase dry-type transformer: separate winding version Three-phase series transformer: autotransformer winding version Three-phase safety, isolating, mains or insulating transformer: separate winding version In terms of how the 3 coils are connected, there are various options available and each of these provides the transformers with specific properties. The vector group code is composed of the following elements: The upper-case letter indicates the higher-voltage winding (the highest voltage in terms of operation). The lower-case letter indicates the lower-voltage winding. The brought-out neutral is indicated by means of N or n (depending on voltage level). â?¢ The distinctive number indicates the phase angle of the lower voltage in relation to the higher voltage (distinctive number multiplied by 30). The following winding connection options are available Delta: D, d Wye (or star): Y, y Zigzag: Z, z Example: Dyn5 Higher-voltage winding is delta-connected. Lower-voltage winding is star-connected with a brought-out neutral. The lower voltage lags behind the higher voltage by 150�° (5 x 30�°). Unless specifically requested otherwise, the transformers are configured with a double-star connection and a brought-out neutral (vector group Yyn0); for autotransformers the vector group is YNa0. Our three-phase transformer range includes all our standardised types for the 25 30.0 kVA performance range and a frequency of 50/60 Hz
1.Dry transformers with high and low voltage windings are coated by a thin layer of epoxy resin.It has the advantages of flame retardant, self-extinguishing, moisture-proof, heat dissipation and so on. 2.Equipped with a low-noise air-cooled device, the fan can be automatically controlled to start and close through the thermostat, so that the transformer can be operated with a 40% increase in capacity. 3.It can go deep into load centers, such as high-rise buildings, airports, wharfs, power plants, residential communities or complete sets of substations. 4.The temperature sensing element and the sensing system embedded in the low voltage winding can start and turn off the fan or alarm or trip according to the set value for protection.
Overview Low no-load loss, better quality! Safety 1. Product accepts the NOMEX Paper Insulation System with high level of inflaming retarding, anti-explosion, and fire rating. 2. Professional technology, excellent performance in mechanical strength and short-circuit resistance and long serve time. Reliable 1. H-class heat-resisting temperature: 180¡æ,C-class level for the major insulating material (220¡æ) with efficient overload capacity. 2. Low partial discharge, high level of insulation with long serve time; 3. NBC protection, no crack display. Environmental Friendly Product uses Nomex Paper as the main insulation material, which create fire retardation, high insulation level, low partial discharge, long service life. Transformer Insulation Bass H, main material insulation class C, it increases the overloading capacity. Low noise level and the copper can be recycling after the life cycle of the transformer. Transformer has high capability to resists moisture, dust and salt. Amorphous Core 1) All raw material are supplied by Hitachi Metals with iron loss less than 70-80% of the standard silicon steel. 2) Company has special treatment, procedure and manufacturer process; which has patent number as: 200810238258.6, 20082015857.5, 200820215858.X, 200820215812.8, 200820215814.7. 3) Core structure is dean and strong, which do not influenced by the movement created during transportation. 4) The three column structure has capability to withstand high level harmonics, and vector group can be in Dyn11, Yyn0. Low Voltage Winding features LV uses high quality imported copper foil and class H insulation foil to apply on polyester-imides. In between each layer, it uses Nomex paper. Windings are insulated by vacuum pressure impregnation (VPI) systems, which make it into concrete form. Both ends of the winding drum have applied resin to seal the ends. 1) For better withstand of short circuit capability 2) For better thermo shock resistance and enhance the life expectancy of the transformer 3) Winding has high capability to resists moisture, dust and salt. High voltage winding features HV winding uses several layer coil type with vertical airway structure. It wraps Nomex paper on to copper for insulation. In between each layer, it uses Nomex paper for insulate. Vacuum, pressure, impregnation (VPI system has applied on the coil to make the structure concrete. Both ends are sealed by resin. 1) Multi-layer design can enhance the inrush capability 2) Enhance short circuit capability 3) High insulation level on the insulation material with good airway throughout the coil design, increase the capability of thermo shock. That way the transformer life expectancy is longer. 4) Winding has high capability to resists moisture, dust and salt
Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) . Protection class: ip00 or as customer required. Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case to the custom made transformer
1. Low energy consumption: The� adoption of isotropic soft magnetic material generates low magnetization power, high electrical resistivity and low eddy current consumption. The no-load loss and current of the core made of amorphous alloy are very low, only 1 / 3 of that of silicon steel sheet. 2. Strong corrosion resistance: the amorphous alloy core� is fully wrapped by resin and high temperature resistant silica glen� which� effectively prevent corrosion and falling off amorphous alloy fragments, and� provide better� protection for the core and coil. 3. Low noise. Improvement of� the structure of iron core and coil and� adoption� of special noise -reduction materials greatly reducing the operation noise. 4. Strong short-circuit resistance. This� product adopts three-phase five-column structure, and the iron core is protected by frame structure. Featured by low temperature-rise and strong heat dissipation, this� product� can work� by� 150% rated load under air cooling condition. Perfect temperature control protection system is applied� to provide reliable guarantee for safe operation of transformer