Gas ignition transformers from 2 outlets to 6 outlets. For gas cookers, gas ovens. Potted with epoxy resin.
Neon Lamp Transformers from 6KV up to 12KV. Potted under vacuum with epoxy resin. Protections: Output open circuit, overload, output short circuit, earth-leakage, input over voltage.
Supplier: Encapsulated transformers, feritte cored transformers, coils, gas ignition transformers, control/isolation transformers
Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs. High temperature resistant liquid-immersed transformer 10kv 30kva-3150kva 35kv 50kva-31500kva
Product Description gel accumulator 2v 800ah (OPzV800-2) OPZV800-2 Opzv Series Valve Regulated Lead Acid batteries are designed with a proven combination of GEL and Tubular technologies to offer a very high level of reliability. Opzv batteries benefit from an optimized plate design which gives capacities in excess of the DIN standard values. In addition, this series offers both a longest float life and a high cycle life in widely industrial field. Safety and Sealed No electrolyte leakage will occur from terminals or case or case of any Storace Battery ensuring safe and efficient operation. Maintenance-Free operation There is no need to add water thanks to unique gas recombination system which totally transforms the generated gas into water. Storace batteries do not need the equalizing charge As a result of monomer battery's interface resistance capacity and float voltage uniformity are fine. No Free Acid The special electrolyte retentive separators bold the acid and thus there is no free acid inside the battery, and therefore the battery can be mounted in any position. Long life Design The use of heavy -duty lead-calcium alloy grids with anti-corrosive construction enables the Storace AGM battery to remain in float service for 10-15 years; the GEL battery to remain in float service for 15-20 years. The cycle life can be more than 1000 cycles High Reliability and stable quality With advancing AGM and GEL production technology and strictly quality control system, the battery quality is stable and the battery performance is reliable. The voltage, capacity and seal are 100% tested on line. Self-discharge The self-discharge rate in room temperature is approximately 2% of nominal Capacity per month. Operating temperature TheStorace Battery can be operated between -40�°C to +65�°C.The battery can give out over40% fo nominal capacity at -40�°C.
110ACV to 12ACV 220-250ACV TO 12ACV US/EUR/AUS three standard products MOQ:100 EA Package: carton
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Supplier: Burners, burner's control components e.G. Valves, modulation motors, solenoid valves, regulators, burner ignition components e.G. Ignition rods, spark rods, flame sensing devices e.G. Uv scanners, flame rods, ignition transformers, flame relays, transform
Services: Consultancy in thermal engineering, heating system design, application engineering, electrical engineers and contractors
Supplier: Gas burner, oil burner, gas & oil dual burner, and accessories (pump, controller, ignition transformers)
Supplier: Voltage regulators, transformers, welding machines