Methanol flow meter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru Methanol flow meter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display of methanol flow meter together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The methanol flow meter with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread Select the JSN and select the methanol flow meter,we will provide the professional service for you.
mini water flow meter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru mini water flow meter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. mini water flow meterr with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread
low flow flowmeter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru Low flow flowmeter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The low flow flowmeter with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread select the low flow flowmeter and jsn WE will provide the professional service for you.
mini flowmeter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru mini flowmeter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The mini flowmeter with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread select the JSN and mini flowmeter we will provide the professional service for you.
micro flow sensor Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru Micro flow sensor(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. Micro flow sensor with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread Select the JSN and micro flow sensor we will provide the professional service for you.
Fluid flow meter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru Fluid flow meter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The fluid flow meter with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread Select the JSN and select the fluid flow meter,we will provide the professional service for you.
Model Mx12x6 Product name Tablet adapter 5v 2a Certification Ce/ul/kc Color White and black Oem/odm Yes Transfer type Ac/dc Output voltage 5v Output current 2a Output power 10w Input voltage 100-240v Input current 0.3a Input frenquency 50/60 hz Protection Ocp ovp opp scp Ac plug Cn, eu, us, uk, au, kc available Dc cable length 1.2m/1.5m/1.8m Dc connector 5.5*2.5*10, 5.5*2.1*10, 3.5*1.35*10 etc Efficency V Warranty 1 year Load regulation
Model Mx24w1 Product namePower adapter 5v 4a 20w for mini refrigerator CertificationCe/fcc/etl/kcc/saa/tuv/rohs/c-tick etc ColorWhite and black Oem/odm Yes Transfer typeAc/dc Output voltage5v Output current4a Output power 20w Input voltage 100-240v Input current0.3a Input frenquency50/60 hz ProtectionOcp ovp opp scp Ac plug Cn, eu, us, uk, au available Dc cable length1.2m/1.5m/1.8m Dc connector 5.5*2.5*10, 5.5*2.1*10, 3.5*1.35*10 etc Use type Wall-mount /desktop EfficencyV Warranty1 year Load regulation
Descrition: The CCTV power supply is primarily designed for WUF-GV, PTZ and camera of CCTV system. It’s also used for access, building/house control, intrude alarm and other light-current. It is for desktop or wall-mounted installation. Features: Power up to 9 CCTV CCTV surveillance cameras 12 Volts DC 5 Amp total output Max output current up to 1.1 Amp/Channel 9 individually PTC auto-reset fuses protected outputs Switch mode power supply (regulated voltage) Integral surge protection Individual LED power indication Individual PTC reset-able fuses Internal On/off safety power switch with LED indicator Beige metal housing Technical specifications: Model 12VDC5A9P Power 60W Metal Case Dimension 24.5×20.8×8.7cm Net Weight 2kgs Input Input Voltage 88-264VAC Input Voltage Frequency 50Hz-60Hz Average Input Current 100Vac=1.0A Efficiency =80% Output Output Voltage 12VDC±5% Output Current 5A, 9 channels for 9 sets load Output Ripple Noise(Vp-p) 80mVp-p@25/ Connection Input Three-pin socket Output 9 channels output Dielectric Strength Input to output 1500Vac/60S leakage current=1.5mA Input to FG 1500Vac/60S leakage current=2.0mA FG to output 500Vac/60S leakage current=1.5mA Insulating strength Input to output =20MO/500VDC@25 Leakage Current =0.12mA @AC110V(220V)/25 RG =0.011O@DC8V/25A/25 Competitive Advantages: This is one of the best 12VDC CCTV power supply boxes on the market for security cameras. We replace the cheap "glass fuse" with "PTC" Reset Fuses which will Auto Reset after you fix the short. You don't have to run around town try to find the replacement fuses. All you have to do is to fix the shorts. The red light shorts indicator helps you to know which camera is not working. Dependable and long lasting Warranty: 2 years
Packaging: Export wooden packageBrand: Saihu, OEMTransportation: Ocean,Land,AirPlace of Origin: Zhejiang, ChinaCertificate: ISO9001, SGS, CE, ASME
Model No.: SJM-1/8-SJM-300/8Usage: OxygenPurpose: Gas separationParts: Adsorption TowerNoise Level: LowCertification: SGS, CE, ISO
Specifications: CBN Type PSA Nitrogen generator Flow: 5-3000Nm3/h Purity: 95%-99.999% Dew-point temperature: -40° C or -60 ° C Pressure: 0.1-0.8Mpa
VPSA Oxygen station 1. Compenents of VPSA Oxygen station 1.1 Air Fan and Vacuum Pump Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen. 1.2 Temperature Regulating System Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation. 1.3 Adsorption System The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen . 1.4 Oxygen Buffer Tank Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output. 1.5 Control System 1.5.1 System process is achieved by DOS control system. In this system, valves switches are independently controlled by PLC (Programmable Logic Controller). Analog signals of test sensors communicate with the main control system through specific communication protocols. Relevant data of specific unit can be sent to main control system and remote control signals of main control system can be accepted by specific unit. 1.5.2 In order to ensure safe oxygen supply, functions of interlink, protection, alarm, print, record etc can be provided. 1.5.3 The output variation of oxygen supply can be adjusted by DCS control system. System operating parameters can be adjusted to save energy. 1.5.4 The main control system adopts industry computer, provided with specific software and convenient human-machine touching screen, Start/stop and operating parameter collection can be realized on control panel. Remote monitor and print of running status record can be easily achieved.
Cryogenic Air Separation Plant 1. Model: KDN-100 2. MOQ:1 set 3. Warranty:1 year 4. Delivery:5-7 months
Pursuing perfection of technology-supported products – Based on technical professionals and high-tech facillities, westrive to develop products and create new technogoles, and we also pursue perfect quality control and customer-oriented business. Strong structure and powerfull durability – Suntech’s generator miniizes the vibration and the noise of the engine. It not worn out and the consume grease so it has excelent durability. In case there is any proublem with the system, it itself diagnoses. Bed frame – FEM technique, fule tank built-in, One body structure, mounting hall. Features – Simple operation, Easy installation, low operations cost, auto stop protection, prompt, delivery, Compact structure for reduse for instllation place. -
Digital tension meter T2 Series tension meter Detailed Product Description: T2 Series Digital Tension meter are for accurately measuring the running line tensions on a wide variety of yarns,fibers and copper wires. Features: Easy to read: 128*64 LCD display panel,clear display with high brightness backlight. Clean Streamlined handle design ,easy handing. Trigger-operated roller shifting mechanism,easy to acquire the running material. Simple and user friendly fuctional buttons for easy operation. Direct display of real time measurement,with present maximum and minimum values displayed simultaneously. Powered by replaceable lithium battery. With memory back up function. Display unit selectable (gram/CN) Accuracy +/-1% R.C Power: Lithium Battery 6V/750m AH
Engine : Cummins - Mitsubishi - Perkins Alternator : Stamford - MeccAlte - Mitsubishi Control System : P 732 control system Water cooled diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Steel base frame and anti-vibration isolators Spare external fuel tank (open set) Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately Static battery charger Manual for application and installation Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 Generators Sets’ can take 100% load at one step according to NFPA110 ISO8528 This generator set has been designed to meet ISO 8528 regulation. SZUTEST This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. 2000/14/EC Enclosed product is tested according to EU noise legislation 2000/14/EC Please Ask For Price
4 Input Channel PV Array Combiner Box for Controller System Description PV combiner box is used to bring together the output DC current of the PV array. It will combine the same solar panels which in series to form a PV Array ,supporting the use of photovoltaic grid-connected inverter, so as to constitute a complete photovoltaic system, with the city electric grid. Summarize BPVB series PV Array Combiner For a large-scale grid-connected PV system, it is a general practice to install a DC combining device in between the PV modules and inverters for the sake of minimizing the cable distance between them, facilitating maintenance and improving reliability. With many years of PV grid-connected system design experience, our BPVB PV array combiner box series is specially-designed for meeting the need of high performance and high reliability of PV systems. In combining with our Solar Access inverters, Bangzhao BPVB provides a turnkey solution for PV power plant systems. By using PV array combiner box, according to the input voltage of the inverter, Clients can connect a fixed number of similar PV modules to form a PV array. Then different strings of PV array can be converged into the PV array string box. After that, together with lightning arresters and circuit breakers, it is connecting to the inverter to reduce the system installation time and increase the system safety. Features of PV array combiner box: * Applicable for outdoor PV systems * Each PV array attached to DC fuse protection and anti-reverse protection optional * Wide DC voltage input range with maximum open-circuit voltage up to 1000V * High voltage lightning protection (SPD) special for PV * PG Cable glands connector input, convenient and safe system wiring * PV special high voltage circuit breaker control output * Output Waterproof terminals
For further details, please, contact us by e-mail. For further details, please, contact us by e-mail.
Capacity: 1-1000 Nm3/hr Purity: 99.5% Outlet pressure:0.2 - 0.4 bar Crygenic oxygen plant -