Capacity: 1-1000 Nm3/hr
Purity: 99.5%
Outlet pressure:0.2 - 0.4 bar
Crygenic oxygen plant
-
Cryogenic Oxygen/ Nitrogen Plant 500 M3/ Hr This plant has 2 Options: Option-1: Oxygen Gas: 500 M3/Hr Purity: 99.5% O2 and above Pressure: 150 Kg/Cm2 g 1714 Cylinders per Day Production of 7 M3 Each Cylinder Capacity (2000 Cylinders per Day Production of 6 M3 Each Cylinder Capacity). Option-2: Oxygen Gas: 350 M3/Hr Nitrogen Gas: 150 M3/Hr Purity O2 : 99.5% and above Purity N2 : 99.5% and above Pressure: 150 Kg/Cm2 g Gross Weight: 80 Tons Assembly Height: 13.5 Mtrs Area Required: 25 x 16 Mtrs Total Power Requirement: 808 KW Power Consumption: 0.9 Unit / M3 (We have various models available from 50 M3/Hr to 500 M3/ Hr for Oxygen/ Nitrogen Generation)
Oxygen Plant Introduction: The Oxygen Plant is based on PSA (Pressure Swing Adsorption) Technology, which is more and more popular used for on-site oxygen supply or filling oxygen cylinders. Our Oxygen Plant with cylinder filling station consists of air compressor, air dryer, air filters, PSA oxygen generator, oxygen compressor, cylinder filling station and related control system. The patented design enable our Oxygen Plant a lowest energy consumption and best efficiency. Oxygen Plant specifications: 1. Oxygen Production capacity: 3~200Nm3/h (12cylinders/day to 800 cylinders/day) 2. Oxygen purity: 93+/-3% 3. Oxygen output pressure: 1-5bar 4. Pressure for filling oxygen cylinders: 150bar (after oxygen booster) 5. The Oxygen Generator can be used for filling oxygen cylinders or onsite application; 6. Skid-mounted enable an easy installation and transportation. Standard Oxygen Plant: ModelProd capacity (Nm3/h)O2 purity (%)Outlet pressure (bar)Compressed air Min. (m3/min)Working pressure (bar)Power consumption (KW) STPO-4493+/-3%1-50.865.5-7.55.43 STPO-5593+/-3%1-51.175.5-7.57.60 STPO-8893+/-3%1-51.875.5-7.511.75 STPO-101093+/-3%1-52.335.5-7.515.75 STPO-151593+/-3%1-53.255.5-7.519.05 STPO-202093+/-3%1-54.305.5-7.531.59 STPO-252593+/-3%1-55.805.5-7.531.59 STPO-303093+/-3%1-57.005.5-7.539.04 STPO-353593+/-3%1-57.585.5-7.547.00 STPO-404093+/-3%1-59.305.5-7.557.70 STPO-454593+/-3%1-510.55.5-7.557.70 STPO-505093+/-3%1-510.65.5-7.557.70 STPO-606093+/-3%1-514.05.5-7.577.70 STPO-656593+/-3%1-515.25.5-7.592.70 STPO-707093+/-3%1-516.25.5-7.592.70 STPO-808093+/-3%1-518.75.5-7.5114.5 STPO-909093+/-3%1-520.05.5-7.5114.5 STPO-10010093+/-3%1-523.35.5-7.5137.0 STPO-16016093+/-3%1-537.45.5-7.5229.0 STPO-20020093+/-3%1-546.75.5-7.5274.0 Remark: Above standard model Oxygen Plant is based on an altitude of
Supplier: Gas products, nitrogen, oxygen, and hydrogen gas production generator, plants
FEATURES AGM & Gel Technology Available in 12 Volts & 2 Volts Series 10 Years Design Life (25 C) Front Access Terminal for easy Installation & Maintenance Flame Retardant Container & Cover with ABS Material High Reliability & Long Cycle Life PRODUCT APPLICATION Cable Television Communication Equipments Electric Power Systems Security Systems UPS systems Control Equipments Medical Equipments Emergency Power Systems Power Plant Characteristics Battery capacity and performance. The AGM has more electrolytes because the gelling agent displaces the electrolytes. This give the battery 7%-8% more duration capacity. The AGM also has a lower internal drop that allows a longer run despite a high discharge rate Elevated temperature. The AGM battery is more efficient in the oxygen recombination cycle that allows it to draw 50% more float current. But the Gel cell is 15% more efficient in heat conduction because the gelled electrolytes are in complete contact with the plates and walls of the container. Float service life. Both the AGM and Gel VRLA batteries have the same 95%-100% capacity. Specifications Nominal Voltage : 12V Capacity @ 20 HR : 12 AH Dimensions (mm)L : 150 Dimensions (mm)W : 98 Dimensions (mm)H : 95 Dimensions (mm)TH : 100 Battery Weight (Kg) : 3.6
6-GFMJ-20 FEATURES AGM & Gel Technology Available in 12 Volts & 2 Volts Series 10 Years Design Life (25 �°C) Front Access Terminal for easy Installation & Maintenance Flame Retardant Container & Cover with ABS Material High Reliability & Long Cycle Life PRODUCT APPLICATION Uninterruptible Power Supply (UPS) Emergency Lightning Power Plants Telecom Backup Power Supplies Lawn & Garden Tools Gen set starting Auto Control Equipments Solar Energy Railway Signaling System Characteristics Battery capacity and performance. The AGM has more electrolytes because the gelling agent displaces the electrolytes. This give the battery 7%-8% more duration capacity. The AGM also has a lower internal drop that allows a longer run despite a high discharge rate Elevated temperature. The AGM battery is more efficient in the oxygen recombination cycle that allows it to draw 50% more float current. But the Gel cell is 15% more efficient in heat conduction because the gelled electrolytes are in complete contact with the plates and walls of the container Float service life. Both the AGM and Gel VRLA batteries have the same 95%-100% capacity Specifications Nominal Voltage 12V Capacity @ 20 HR 20 AH Dimensions (mm) L 180 Dimensions (mm) W 76 Dimensions (mm) H 175 Dimensions (mm) TH 126 Weight KG 8.0
6-GFM-18 FEATURES AGM & Gel Technology Available in 12 Volts & 2 Volts Series 10 Years Design Life (25 �°C) Front Access Terminal for easy Installation & Maintenance Flame Retardant Container & Cover with ABS Material High Reliability & Long Cycle Life PRODUCT APPLICATION Uninterruptible Power Supply (UPS) Emergency Lightning Power Plants Telecom Backup Power Supplies Lawn & Garden Tools Gen set starting Auto Control Equipments Solar Energy Railway Signaling System Characteristics Battery capacity and performance. The AGM has more electrolytes because the gelling agent displaces the electrolytes. This give the battery 7%-8% more duration capacity. The AGM also has a lower internal drop that allows a longer run despite a high discharge rate. Elevated temperature. The AGM battery is more efficient in the oxygen recombination cycle that allows it to draw 50% more float current. But the Gel cell is 15% more efficient in heat conduction because the gelled electrolytes are in complete contact with the plates and walls of the container. Float service life. Both the AGM and Gel VRLA batteries have the same 95%-100% capacity. Specifications Nominal Voltage 12V Capacity @ 20 HR 18 AH Dimensions (mm)L 180 Dimensions (mm)W 75 Dimensions (mm)H 168 Dimensions (mm)TH 168 Battery Weight (Kg) 5.7
VPSA Oxygen station 1. Compenents of VPSA Oxygen station 1.1 Air Fan and Vacuum Pump Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen. 1.2 Temperature Regulating System Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation. 1.3 Adsorption System The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen . 1.4 Oxygen Buffer Tank Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output. 1.5 Control System 1.5.1 System process is achieved by DOS control system. In this system, valves switches are independently controlled by PLC (Programmable Logic Controller). Analog signals of test sensors communicate with the main control system through specific communication protocols. Relevant data of specific unit can be sent to main control system and remote control signals of main control system can be accepted by specific unit. 1.5.2 In order to ensure safe oxygen supply, functions of interlink, protection, alarm, print, record etc can be provided. 1.5.3 The output variation of oxygen supply can be adjusted by DCS control system. System operating parameters can be adjusted to save energy. 1.5.4 The main control system adopts industry computer, provided with specific software and convenient human-machine touching screen, Start/stop and operating parameter collection can be realized on control panel. Remote monitor and print of running status record can be easily achieved.
Supplier: Nitrogen generators, membrane nitrogen plants, psa oxygen generators, ammonia crackers
Buyer: Air compressors
Supplier: Liquid nitrogen plant,medical oxygen plant,compressed air line filter,medical vacuum filter,laboratory n2,h2,zero air generator, replacement compressed air filter element