VPSA Oxygen station
1. Compenents of VPSA Oxygen station
1.1 Air Fan and Vacuum Pump
Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen.
1.2 Temperature Regulating System
Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation.
1.3 Adsorption System
The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen .
1.4 Oxygen Buffer Tank
Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output.
1.5 Control System
1.5.1 System process is achieved by DOS control system. In this system, valves switches are independently controlled by PLC (Programmable Logic Controller). Analog signals of test sensors communicate with the main control system through specific communication protocols. Relevant data of specific unit can be sent to main control system and remote control signals of main control system can be accepted by specific unit.
1.5.2 In order to ensure safe oxygen supply, functions of interlink, protection, alarm, print, record etc can be provided.
1.5.3 The output variation of oxygen supply can be adjusted by DCS control system. System operating parameters can be adjusted to save energy.
1.5.4 The main control system adopts industry computer, provided with specific software and convenient human-machine touching screen, Start/stop and operating parameter collection can be realized on control panel. Remote monitor and print of running status record can be easily achieved.
Supplier: Cryogenic atmospheric flat bottom storage tanks, vacuum insulated storage / microbulk tanks, vpsa oxygen generator / plant, air separation units (asu).
Supplier: PSA nitrogen generators, PSA oxygen generator, VPSA oxygen generators, cryogenic air separation plant, nitrogen generator, capsule filling machine
Oxygen Plant Introduction: The Oxygen Plant is based on PSA (Pressure Swing Adsorption) Technology, which is more and more popular used for on-site oxygen supply or filling oxygen cylinders. Our Oxygen Plant with cylinder filling station consists of air compressor, air dryer, air filters, PSA oxygen generator, oxygen compressor, cylinder filling station and related control system. The patented design enable our Oxygen Plant a lowest energy consumption and best efficiency. Oxygen Plant specifications: 1. Oxygen Production capacity: 3~200Nm3/h (12cylinders/day to 800 cylinders/day) 2. Oxygen purity: 93+/-3% 3. Oxygen output pressure: 1-5bar 4. Pressure for filling oxygen cylinders: 150bar (after oxygen booster) 5. The Oxygen Generator can be used for filling oxygen cylinders or onsite application; 6. Skid-mounted enable an easy installation and transportation. Standard Oxygen Plant: ModelProd capacity (Nm3/h)O2 purity (%)Outlet pressure (bar)Compressed air Min. (m3/min)Working pressure (bar)Power consumption (KW) STPO-4493+/-3%1-50.865.5-7.55.43 STPO-5593+/-3%1-51.175.5-7.57.60 STPO-8893+/-3%1-51.875.5-7.511.75 STPO-101093+/-3%1-52.335.5-7.515.75 STPO-151593+/-3%1-53.255.5-7.519.05 STPO-202093+/-3%1-54.305.5-7.531.59 STPO-252593+/-3%1-55.805.5-7.531.59 STPO-303093+/-3%1-57.005.5-7.539.04 STPO-353593+/-3%1-57.585.5-7.547.00 STPO-404093+/-3%1-59.305.5-7.557.70 STPO-454593+/-3%1-510.55.5-7.557.70 STPO-505093+/-3%1-510.65.5-7.557.70 STPO-606093+/-3%1-514.05.5-7.577.70 STPO-656593+/-3%1-515.25.5-7.592.70 STPO-707093+/-3%1-516.25.5-7.592.70 STPO-808093+/-3%1-518.75.5-7.5114.5 STPO-909093+/-3%1-520.05.5-7.5114.5 STPO-10010093+/-3%1-523.35.5-7.5137.0 STPO-16016093+/-3%1-537.45.5-7.5229.0 STPO-20020093+/-3%1-546.75.5-7.5274.0 Remark: Above standard model Oxygen Plant is based on an altitude of
Cryogenic Oxygen/ Nitrogen Plant 500 M3/ Hr This plant has 2 Options: Option-1: Oxygen Gas: 500 M3/Hr Purity: 99.5% O2 and above Pressure: 150 Kg/Cm2 g 1714 Cylinders per Day Production of 7 M3 Each Cylinder Capacity (2000 Cylinders per Day Production of 6 M3 Each Cylinder Capacity). Option-2: Oxygen Gas: 350 M3/Hr Nitrogen Gas: 150 M3/Hr Purity O2 : 99.5% and above Purity N2 : 99.5% and above Pressure: 150 Kg/Cm2 g Gross Weight: 80 Tons Assembly Height: 13.5 Mtrs Area Required: 25 x 16 Mtrs Total Power Requirement: 808 KW Power Consumption: 0.9 Unit / M3 (We have various models available from 50 M3/Hr to 500 M3/ Hr for Oxygen/ Nitrogen Generation)
Oxygen source ozone generator Oxygen source ozone generator 1 / water treatment ozone generator 2 / chemical oxidation ozone generator 3 / laboratory ozone generator 4 / small ozone generator 5 / high concentration ozone generator 6 / oxygen source ozone generator 7 / Pure water ozone generator 8/etc The main technical features of OF-series high concentration ozone generator: The ozone tube of this equipment introduces the most advanced technology of hufo in Germany, adopts the nano-ceramic glass medium imported from Germany, and the dielectric constant is higher than that of enamel and ceramic. The wall thickness is uniform and the ellipticity is accurate. The temperature is -50 °C to 1050. °C, moisture resistance (return water failure-free), oxidation resistance, high mechanical strength, high voltage resistance of 30,000 volts without breakdown. The electrode is made of CNC high-purity and corrosion-resistant high-quality titanium alloy. The tube seal is made of high-quality tetrafluoroethylene (PTFE) material and does not leak ozone gas and coolant. There is a small gap between the dielectric tube and the electrode, and there is no expansion coefficient difference to cause the dielectric tube to burst (enamel dielectric tube). The dielectric tube is sintered by nano-crystal technology, and it will not generate ash during the ozone generation process. It will make the life of machine longer. Because cooling methods are air-cooling and liquid-cooled double cooling, the ozone output is constant and the ozone concentration is high, so that the power consumption is lower and energy-saving. The outer casing are made of corrosion-resistant stainless steel. The cooling method are forced air cooling and water cooling. The high-power flyback high-frequency power,stable performance. Oxygen is used as a gas source by using bottled oxygen or by using a small oxygen generator. The advantages are high ozone concentration,no nitrogen oxides,small volume,structural modularity,ozone production can be self-regulated,easy to operate and maintain and very low investment and usage costs.
Mobile Oxygen Generator Introduction: The Mobile Oxygen Generator is based on PSA (Pressure Swing Adsorption) Technology, which uses some specific molecular sieves (ZMS) to separate the Oxygen gas from the air. It is more and more popular used for on-site Oxygen supply, or even for some specific gas station which has to move frequently. ShinTek Mobile Oxygen Generator consists of air compressor, air dryer, air filters, PSA Oxygen generator, optional cylinder filling system and related control system. There are three types for choose: skid-mounted, container mounted or vehicle mounted. Mobile Oxygen Generator specifications: 1. Oxygen production capacity: 5 ~ 100 Nm3/h 2. Oxygen purity: 93+/-3%; 3. Oxygen pressure from the Oxygen Generator: 1-5bar 4. Oxygen pressure can be boosted to be as higher as 150bar per customer’s demand. 5. Skid-mounted, Container mounted, Vehicle mounted; Mobile Oxygen Generator Features: (1) Three types for choose: skid-mounted or container-mounted or vehicle-mounted; (2) The Mobile Oxygen Generator is equipped with a stable screw air compressor; (3) The Mobile Oxygen Generator use Siemens PLC and SMC valves; (4) Fewer moving parts enable the Mobile Oxygen Generator more reliable, and less maintenance jobs; (5) The Mobile Oxygen Generator is very easy to be operated, unmanned operation can be realized; (6) The Mobile Oxygen Generator is energy efficient (0.3 KWH/m3 Oxygen), save energy; (7) Consumable parts: only filter elements, replaced every 6000-8000hours. Maintenance cost is very low.
Oxygen Generator Introduction: The Oxygen Generator is based on PSA (Pressure Swing Adsorption) Technology, which is more and more popular used for on-site oxygen supply or filling oxygen cylinders. Our Oxygen Generator consists of air compressor, air dryer, air filters, PSA oxygen generator, and related control system. The patented design enable our PSA Oxygen Generator a lowest energy consumption and best efficiency. Oxygen Generator specifications: 1. Oxygen Production capacity: 2~200Nm3/h (12cylinders/day to 800 cylinders/day) 2. Oxygen purity: 93+/-3% 3. Oxygen output pressure: 1-5bar 4. Pressure for filling oxygen cylinders: 150bar (after oxygen booster) 5. The Oxygen Generator can be used for filling oxygen cylinders or onsite application; 6. Skid-mounted enable an easy installation and transportation. Standard Oxygen Generator: ModelProd capacity (Nm3/h)O2 purity (%)Outlet pressure (bar)Compressed air Min. (m3/min)Working pressure (bar)Power consumption (KW) STPO-4493+/-3%1-50.865.5-7.55.43 STPO-5593+/-3%1-51.175.5-7.57.60 STPO-8893+/-3%1-51.875.5-7.511.75 STPO-101093+/-3%1-52.335.5-7.515.75 STPO-151593+/-3%1-53.255.5-7.519.05 STPO-202093+/-3%1-54.305.5-7.531.59 STPO-252593+/-3%1-55.805.5-7.531.59 STPO-303093+/-3%1-57.005.5-7.539.04 STPO-353593+/-3%1-57.585.5-7.547.00 STPO-404093+/-3%1-59.305.5-7.557.70 STPO-454593+/-3%1-510.55.5-7.557.70 STPO-505093+/-3%1-510.65.5-7.557.70 STPO-606093+/-3%1-514.05.5-7.577.70 STPO-656593+/-3%1-515.25.5-7.592.70 STPO-707093+/-3%1-516.25.5-7.592.70 STPO-808093+/-3%1-518.75.5-7.5114.5 STPO-909093+/-3%1-520.05.5-7.5114.5 STPO-10010093+/-3%1-523.35.5-7.5137.0 STPO-16016093+/-3%1-537.45.5-7.5229.0 STPO-20020093+/-3%1-546.75.5-7.5274.0 Remark: Above standard model Oxygen Generator is based on an altitude of
Model No.: SJM-1/8-SJM-300/8Usage: OxygenPurpose: Gas separationParts: Adsorption TowerNoise Level: LowCertification: SGS, CE, ISO
Capacity: 1-1000 Nm3/hr Purity: 99.5% Outlet pressure:0.2 - 0.4 bar Crygenic oxygen plant -