Please click here to check who's online and chat with them.

Hangzhou Saihu Air Separation Equipment Co., Ltd.

Supplier From China
Aug-24-16
Supplier : PSA oxygen generators , on site oxygen generator , high purity oxygen machine

Established: 1998

Verification Status



Contact Details:
Chang Kou Industrial Park, Fuyang
Hangzhou 311411
Zhejiang China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Hangzhou Saihu Air Separation Equipment Co., Ltd.

Aug-25-16
 
Model No.: SJM-1/8-SJM-300/8Usage: OxygenPurpose: Gas separationParts: Adsorption TowerNoise Level: LowCertification: SGS, CE, ISO
Aug-25-16
 
VPSA Oxygen station
1. Compenents of VPSA Oxygen station
1.1 Air Fan and Vacuum Pump
Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen.
1.2 Temperature Regulating System
Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation.
1.3 Adsorption System
The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen .
1.4 Oxygen Buffer Tank
Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output.
1.5 Control System
1.5.1 System process is achieved by DOS control system. In this system, valves switches are independently controlled by PLC (Programmable Logic Controller). Analog signals of test sensors communicate with the main control system through specific communication protocols. Relevant data of specific unit can be sent to main control system and remote control signals of main control system can be accepted by specific unit.
1.5.2 In order to ensure safe oxygen supply, functions of interlink, protection, alarm, print, record etc can be provided.
1.5.3 The output variation of oxygen supply can be adjusted by DCS control system. System operating parameters can be adjusted to save energy.
1.5.4 The main control system adopts industry computer, provided with specific software and convenient human-machine touching screen, Start/stop and operating parameter collection can be realized on control panel. Remote monitor and print of running status record can be easily achieved.
Aug-25-16
 
Packaging: Export wooden packageBrand: Saihu, OEMTransportation: Ocean,Land,AirPlace of Origin: Zhejiang, ChinaCertificate: ISO9001, SGS, CE, ASME
Aug-25-16
 
Specifications: CBN Type PSA Nitrogen generator
Flow: 5-3000Nm3/h
Purity: 95%-99.999%
Dew-point temperature: -40° C or -60 ° C
Pressure: 0.1-0.8Mpa
Aug-25-16
 
Cryogenic Air Separation Plant
1. Model: KDN-100
2. MOQ:1 set
3. Warranty:1 year
4. Delivery:5-7 months
Aug-10-16

Psa Oxygen Generator

$2.0k - $1,500.0k
MOQ: Not Specified
 
Oxygen Generator Introduction:

The Oxygen Generator is based on PSA (Pressure Swing Adsorption) Technology, which is more and more popular used for on-site oxygen supply or filling oxygen cylinders.

Our Oxygen Generator consists of air compressor, air dryer, air filters, PSA oxygen generator, and related control system. The patented design enable our PSA Oxygen Generator a lowest energy consumption and best efficiency.

Oxygen Generator specifications:

1. Oxygen Production capacity: 2~200Nm3/h (12cylinders/day to 800 cylinders/day)
2. Oxygen purity: 93+/-3%
3. Oxygen output pressure: 1-5bar
4. Pressure for filling oxygen cylinders: 150bar (after oxygen booster)
5. The Oxygen Generator can be used for filling oxygen cylinders or onsite application;
6. Skid-mounted enable an easy installation and transportation.

Standard Oxygen Generator:

ModelProd capacity (Nm3/h)O2 purity (%)Outlet pressure (bar)Compressed air Min. (m3/min)Working pressure (bar)Power consumption (KW)
STPO-4493+/-3%1-50.865.5-7.55.43
STPO-5593+/-3%1-51.175.5-7.57.60
STPO-8893+/-3%1-51.875.5-7.511.75
STPO-101093+/-3%1-52.335.5-7.515.75
STPO-151593+/-3%1-53.255.5-7.519.05
STPO-202093+/-3%1-54.305.5-7.531.59
STPO-252593+/-3%1-55.805.5-7.531.59
STPO-303093+/-3%1-57.005.5-7.539.04
STPO-353593+/-3%1-57.585.5-7.547.00
STPO-404093+/-3%1-59.305.5-7.557.70
STPO-454593+/-3%1-510.55.5-7.557.70
STPO-505093+/-3%1-510.65.5-7.557.70
STPO-606093+/-3%1-514.05.5-7.577.70
STPO-656593+/-3%1-515.25.5-7.592.70
STPO-707093+/-3%1-516.25.5-7.592.70
STPO-808093+/-3%1-518.75.5-7.5114.5
STPO-909093+/-3%1-520.05.5-7.5114.5
STPO-10010093+/-3%1-523.35.5-7.5137.0
STPO-16016093+/-3%1-537.45.5-7.5229.0
STPO-20020093+/-3%1-546.75.5-7.5274.0
Remark: Above standard model Oxygen Generator is based on an altitude of
GOLD Member
VERIFIED
Feb-25-25
 
Generator
Sep-15-21
 
Description:
Portable Medical Oxygen Molecular Sieve is high-efficiency oxygen molecular sieve of X-type molecular sieve(pore diameter:10 angstroms). It is suitable for household and medical oxygen generator with PSA. It has good selectivity of N2/O2. Easily desorption.

Technical Parameter:
Properties Unit Bead
Diameter mm 0.4-0.8 1.6-2.8
Bulk density g/ml 0.62 0.62
Crushing strength N/pce / 30.0
N2 Capacity
(1 bar,25) ml/g 8.0 8.0
N2/O2 Selectivity
(1 bar,25) - 3.0 3.0
Particle Ration wt% 95.0 97.0
Attrition wt% 0.30 0.30
Static H2O capacity
(RH=60%,25) wt% 30.0 30.0
Static CO2 capacity
(250mmHg,25) wt% 19.8 19.8
Loss on Ignition
(575,1hr) wt% 1.0 1.0

Application:
PSA industrial oxygen production and medical center oxygen supply system
Jul-27-18
 
Oxygen source ozone generator
Oxygen source ozone generator 1 / water treatment ozone generator 2 / chemical oxidation ozone generator 3 / laboratory ozone generator 4 / small ozone generator 5 / high concentration ozone generator 6 / oxygen source ozone generator 7 / Pure water ozone generator 8/etc

The main technical features of OF-series high concentration ozone generator:
The ozone tube of this equipment introduces the most advanced technology of hufo in Germany, adopts the nano-ceramic glass medium imported from Germany, and the dielectric constant is higher than that of enamel and ceramic. The wall thickness is uniform and the ellipticity is accurate. The temperature is -50 °C to 1050. °C, moisture resistance (return water failure-free), oxidation resistance, high mechanical strength, high voltage resistance of 30,000 volts without breakdown. The electrode is made of CNC high-purity and corrosion-resistant high-quality titanium alloy. The tube seal is made of high-quality tetrafluoroethylene (PTFE) material and does not leak ozone gas and coolant. There is a small gap between the dielectric tube and the electrode, and there is no expansion coefficient difference to cause the dielectric tube to burst (enamel dielectric tube). The dielectric tube is sintered by nano-crystal technology, and it will not generate ash during the ozone generation process. It will make the life of machine longer. Because cooling methods are air-cooling and liquid-cooled double cooling, the ozone output is constant and the ozone concentration is high, so that the power consumption is lower and energy-saving. The outer casing are made of corrosion-resistant stainless steel. The cooling method are forced air cooling and water cooling. The high-power flyback high-frequency power,stable performance. Oxygen is used as a gas source by using bottled oxygen or by using a small oxygen generator. The advantages are high ozone concentration,no nitrogen oxides,small volume,structural modularity,ozone production can be self-regulated,easy to operate and maintain and very low investment and usage costs.

Verification Status