Model: SJ1200 1.0kw Rated Frequency (Hz): 50/60 Rated Voltage (V): 110/120/220/230/240 Max. Power Output (KW): 1.0 / 1.2 Rated Power Output (KW): 0.8 / 1.0 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ154F Bore Stroke (mm): 54 46 Compression Ratio: 6.8: 1 Starting System: Recoil Start Engine Oil Capacity (L): 0.45 Fuel Tank Capacity (L): 4 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 25/26 Dimension (L W H): 445 345 411 20FT (set): 420
Model: SJ2500 2kw Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 2.3 / 2.5 Rated Power Output ( KW ): 2.1 / 2.3 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ170FE Bore Stroke ( mm ): 70 54 Compression Ratio: 8.5 : 1 Starting System: Recoil Start & Electric Start Engine Oil Capacity ( L ): 0.6 Fuel Tank Capacity ( L ): 15 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 44 / 47 Dimension (LWH): 610 450 465 20FT (set) : 240
Model: SJ3000 2.5kw Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 2.8 / 3.0 Rated Power Output ( KW ): 2.5 / 2.7 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ170F Bore Stroke ( mm ): 70 54 Compression Ratio: 8.5 : 1 Starting System: Recoil Start Engine Oil Capacity ( L ): 0.6 Fuel Tank Capacity ( L ): 15 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 42 / 45 Dimension (LWH): 610 450 465 20FT (set): 240
Model: SJ3500-1 3kw170F Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 3.2 / 3.5 Rated Power Output ( KW ): 3.0 / Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ170F Bore Stroke ( mm ): 70 54 Compression Ratio: 8.2 : 1 Starting System: Recoil Start Engine Oil Capacity ( L ): 1.1 Fuel Tank Capacity ( L ): 25 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 62 / 65 Dimension (LÃ?WÃ?H): 695 530 580 20FT (set) : 13 0
Model: SJ5500 5kw Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 5.5 / 6.0 Rated Power Output ( KW ): 5.0 / 5.5 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ190F Bore Stroke ( mm ): 90 64 Compression Ratio: 8.3 : 1 Starting System: Recoil Start Engine Oil Capacity ( L ): 1.1 Fuel Tank Capacity ( L ): 25 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 84 / 86 Dimension (LWH): 695 530 580 20FT (set) : 130
Single cylinder, forced air cooling,4-stroke gasoline engine Model: GX160 5.5hp Displacement: 163 (cc) Bore Stroke: 68mm 45mm Rated Power Output: 4.6HP (3.4)KW / 3600rpm Max. Power Output : 5.5HP (4.0)KW / 3600rpm Torque (N.M): 11 / 2500 Compression Ratio: 8.5 : 1 Fuel Tank Capacity: 3.6 (L) Engine Oil Capacity: 0.6 (L) Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder Ignition System: Transistor Magneto Starting System: Recoil Start N.W. / G.W. (KG): 15 / 17 Dimension (LWH): 400 370 375 20FT (set): 520
Single cylinder, forced air cooling,4-stroke gasoline engine Model: GX200 6.5hp Displacement: 196 (cc) Bore Ã? Stroke: 68mm Ã? 54mm Rated Power Output: 5.5HP (4.0)KW / 3600rpm Max. Power Output : 6.5HP (4.8)KW / 3600rpm Torque (N.M): 13 / 2500 Compression Ratio: 8.5 : 1 Fuel Tank Capacity: 3.6 (L) Engine Oil Capacity: 0.6 (L) Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder Ignition System: Transistor Magneto Starting System: Recoil Start N.W. / G.W. (KG): 15 / 17 Dimension (LÃ?WÃ?H): 400 Ã? 370 Ã? 375 20FT (set): 520
Model: SJ3200 2.8kw Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 3.0 / 3.2 Rated Power Output ( KW ): 2.8 / 3.0 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ170F Bore Stroke ( mm ): 70 54 Compression Ratio: 8.5 : 1 Starting System: Recoil Start Engine Oil Capacity ( L ): 0.6 Fuel Tank Capacity ( L ): 15 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 43 / 46 Dimension (LWH): 610 450 465 20FT (set) : 240
Model: SJ7000 6.5kw with recoil starter Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 6.5 / 7.0 Rated Power Output ( KW ): 6.0 / 6.5 Phase: Single Voltage Regulate: AVR Power Factor: 1 Engine Model: SJ190F Bore Stroke ( mm ): 90 64 Compression Ratio: 8.3 : 1 Starting System: Recoil Start Engine Oil Capacity ( L ): 1.1 Fuel Tank Capacity ( L ): 25 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 85 / 88 Dimension (LWH): 695 530 580 20FT (set) : 130
Model: SJ7500E 7.5kw Rated Frequency ( Hz ): 50 / 60 Rated Voltage ( V ): 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ): 8.0 Rated Power Output ( KW ): 7.5 Phase: Single Voltage Regulate: AVR Power Factor: 3 Engine Model: SJ192FE Bore Stroke ( mm ): 92 66 Compression Ratio: 8.3 : 1 Starting System: Recoil Start & Electric Start Engine Oil Capacity ( L ): 1.1 Fuel Tank Capacity ( L ): 25 Engine Type: Forced Air-Cooled, 4 Stroke, Single Cylinder N.W. / G.W. (KG): 90/93 Dimension (LWH): 710540595 20FT (set) : 130
Model SJ10000 Rated Frequency ( Hz ) 50 / 60 Rated Voltage ( V ) 110 / 120 / 220 / 230 / 240 Max. Power Output ( KW ) 10.0 / 11.0 Rated Power Output ( KW ) 8.5 / 9.0 Phase Single Voltage Regulate AVR Power Factor 1 Engine Model SJ2V78F Bore Ã? Stroke ( mm ) 78 Ã? 72 Compression Ratio 8.3 : 1 Starting System Electric Start Engine Oil Capacity ( L ) 1.4 Fuel Tank Capacity ( L ) 25 Engine Type V-TWIN-Cylinder,Forced Air-Cooled, 4 Stroke N.W. / G.W. (KG) 158 / 165 Dimension (LÃ?WÃ?H) 92? 69? 780 20FT (set) 48
15 years experienced sauna generator and heater manufacturer in shenzhen, china. Contact freely whenever you need.
Packaging: Export wooden packageBrand: Saihu, OEMTransportation: Ocean,Land,AirPlace of Origin: Zhejiang, ChinaCertificate: ISO9001, SGS, CE, ASME
Model No.: SJM-1/8-SJM-300/8Usage: OxygenPurpose: Gas separationParts: Adsorption TowerNoise Level: LowCertification: SGS, CE, ISO
Specifications: CBN Type PSA Nitrogen generator Flow: 5-3000Nm3/h Purity: 95%-99.999% Dew-point temperature: -40° C or -60 ° C Pressure: 0.1-0.8Mpa
VPSA Oxygen station 1. Compenents of VPSA Oxygen station 1.1 Air Fan and Vacuum Pump Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen. 1.2 Temperature Regulating System Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation. 1.3 Adsorption System The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen . 1.4 Oxygen Buffer Tank Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output. 1.5 Control System 1.5.1 System process is achieved by DOS control system. In this system, valves switches are independently controlled by PLC (Programmable Logic Controller). Analog signals of test sensors communicate with the main control system through specific communication protocols. Relevant data of specific unit can be sent to main control system and remote control signals of main control system can be accepted by specific unit. 1.5.2 In order to ensure safe oxygen supply, functions of interlink, protection, alarm, print, record etc can be provided. 1.5.3 The output variation of oxygen supply can be adjusted by DCS control system. System operating parameters can be adjusted to save energy. 1.5.4 The main control system adopts industry computer, provided with specific software and convenient human-machine touching screen, Start/stop and operating parameter collection can be realized on control panel. Remote monitor and print of running status record can be easily achieved.
Cryogenic Air Separation Plant 1. Model: KDN-100 2. MOQ:1 set 3. Warranty:1 year 4. Delivery:5-7 months
Pursuing perfection of technology-supported products – Based on technical professionals and high-tech facillities, westrive to develop products and create new technogoles, and we also pursue perfect quality control and customer-oriented business. Strong structure and powerfull durability – Suntech’s generator miniizes the vibration and the noise of the engine. It not worn out and the consume grease so it has excelent durability. In case there is any proublem with the system, it itself diagnoses. Bed frame – FEM technique, fule tank built-in, One body structure, mounting hall. Features – Simple operation, Easy installation, low operations cost, auto stop protection, prompt, delivery, Compact structure for reduse for instllation place. -
Engine : Cummins - Mitsubishi - Perkins Alternator : Stamford - MeccAlte - Mitsubishi Control System : P 732 control system Water cooled diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Steel base frame and anti-vibration isolators Spare external fuel tank (open set) Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately Static battery charger Manual for application and installation Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 Generators Sets’ can take 100% load at one step according to NFPA110 ISO8528 This generator set has been designed to meet ISO 8528 regulation. SZUTEST This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. 2000/14/EC Enclosed product is tested according to EU noise legislation 2000/14/EC Please Ask For Price
For further details, please, contact us by e-mail. For further details, please, contact us by e-mail.