Overview: The Intelligent dielectric loss tester also applies to the measurement of tg�´ and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes. It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg of capacitor voltage transformer and capacitance of main capacitor C1and C2. Main Specifications Control panel: printer, keyboard, indicator and communication transferring. Variable frequency power supply: SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage. Step-up transformer: the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA/one minute. Standard capacitor: internal Cn. It is the measuring basis. Cn current detection: it is used to detect the internal standard capacitor current, 10A ~ 1A. The input resistance is
Product description Partial discharge test system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities. Technical Parameters: Rated Capacity 5-1000kVA Impedance Voltage 10% Input Voltage AC 220V/AC 380V Output Voltage Waveform Power frequency sine wave Output Voltage AC 0-1000kV Surface Temperature Oil immersed:
Product description Digital detector partial discharge test and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. Echnical parameter Number of channels: 4 independent measurement channels (scalable) and 1 external trigger input channel. Sampling rate: 200MSa / s Sampling accuracy: 12bit Host Screen size: 6.5 inches Operation: mouse keyboard touch screen Host interface: 2 USB ports 1 Ethernet port 1 VGA port. Synchronous Frequency range: 30Hz ~ 1MHz Power Mode: Built-in lithium battery or external AC power supply (AC220V 50Hz) Measurement content: Discharge magnitude (Q) the discharge phase (?) the discharge density (N) Data processing sampling period: 1s 3 amplitude-time a relationshipmagnitude-phase relationship number of discharges-phase relationship Charging power supply: AC220V; 50Hz frequency System design life: more than 10 years
Product description Petroleum Kinematic Viscometer for conforms to GB/T 265-1988 "Measuring and calculating method for kinematic viscosity of petroleum products", which is applicable to test the kinematic viscosity of liquid petroleum products (Newtonian liquids). It is used to measure the time when a certain volume of liquid flowing through a calibrated glass capillary viscosimeter under the gravity at a constant temperature. The product of capillary viscosimeter constant and flow time is the kinematic viscosity of liquid at that temperature. Technical indexï¼? Display: Color LCD display and touch screen Temperature control range: Room temperature~150
Product description Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry. Technical Parameter CTA-1000 Usage CT PT Output 0~180Vrms 12Arms 36A peak value Voltage measurement accuracy ±0.1% CT Ratio Range 1~40000 accuracy ±0.05% PT Ratio Range 1~40000 accuracy ±0.05% Phase Range ±2min accuracy 0.5min DC resistance Range 0~300 accuracy 0.2%±2m Burden Range 0~1000VA accuracy 0.2%±0.02VA 0.2%±0.02VA Power supply AC220V ±10% 50Hz Environmental Conditions Operating temperature : -10 C~50 C Humidity : 90% Weight and Dimensions Dimensions: 365 mm 290 mm 153mm,Weight
Overview Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB/T507-2002, industry standard DL429.9-91 and the latest Electric Power Industry Standard DL/T846.7-2004 by ourselves. This instrument, by using a single-chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry. Major Technical Indicators 1. Output voltage: 0-100KV (optional) 2. Voltage distortion rate: 3% 3. Voltage raising speed: 0.5-5 KV/S (adjustable) 4. Standing time: 15min (adjustable) 5. Boosting interval: 5 min (adjustable) 6.Boosting frequency: 1-9 time(s) (optional) 7. Booster capacity: 1.5KVA 8.Measuring accuracy: ±3 9. Supply voltage: AC220V ±10% 50Hz±1 Hz 10. Power: 200W 11.Applicable temperature: 0-45 12.Applicable humidity: 75%RH 13. Overall dimension: 465 385 425
Product description The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy: voltage, current: 0.2 level Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Voltage measurement range: AC 3V300V Internal power output range: voltage 0~250V, current 0~10A Current measurement range: AC 0.2A 20A Working temperature: -10-50 Working humidity: 80% Working power supply: AC220V ±10-50Hz ±1Hz Dimensions: 360mm 220mm 150mm Weight of the instrument: 20Kg
Product description Oil dielectric loss tester is a high-precision instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc. It is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. Technical index Oil cup technical specifciations: Distance between High Voltage terminal and Low Voltage terminal 2mm Capacitance of Empty Cup 60±2PF The Highest testing voltage Industrial Frequency 2000V Dielectric Loss of Empty Cup tg 10-4 Liquid capacity About 40ml Electrode Material Stainless Steel Volume 70mm(D) 120mm H 1 Condition of Use -5-40 RH 80% 2 Power Source AC 110V±10% Without Frequency Limit 3 AC High Voltage Output 400V 2200V ±2% Every 100V 50VA 4 DC High Voltage Output 200V 600V ±2% 5 Temperature Control Induction Stove Maximal Power 500W 6 Temperature Control Range
1.Overview: Transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents. The acid value is the trace value of potassium sulfate that neutralizes the petroleum acid in 1g of oil, which contains a certain amount of inorganic acid and inorganic acid. The acid value includes organic and inorganic acids contained in the oil. In most cases, oil does not contain mineral acids. Therefore, the oleic acid value actually represents the content of organic acids in the oil. The organic acid contained in the new oil is mainly cyclonic acid. In the oil and in the process of use, the acid value of the oil produced by oxidation is an indicator to measure the degree of refining of the new oil. Whether the oil is running is an important indicator of the continued use of oil quality equipment. 2. Technical index: 1.Test range: 0.00 1mg KOH/g 2.Test error: ±0.005mg KOH/g 3.Repeatability: 0.005mg KOH/g 4.Ambient temperature: 10-45 5.Relative humidity(RH): 85%RH 6.Voltage supply: AC220V/50Hz 7.Power: 50W
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm Product Characteristics 1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use; 2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment. 3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown; 4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
Product Description: Transformer GIS SF6 switch CT/PT insulator bus bar cable bushing and others capacitive devices are the common primary electric equipments. The complete set of frequency conversion series resonance test equipment is mainly used for ac withstand voltage test of cross-linked cable hydraulic generator main transformer bus GIS etc. The complete set of frequency conversion series resonance test equipment is mainly composed of frequency conversion control power supply excitation transformer reactor capacitor voltage divider and compensation capacitor (optional). Product Parameters: technical parameter Rated output voltage 0 1000kV and below output frequency 30 300Hz Resonance voltage waveform Pure sine wave waveform distortion rate 1.0% Working time Full power continuous working time of 60min Quality factor 30~90 Frequency regulation sensitivity 0.1Hz Instability 0.05% Working power supply Single-phase 220V or three-phase 380V ±10% Power frequency 50Hz ±5%
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Overview The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area. Technical Parameters Technical parameters Measurement voltage range 0.5kV 1kV 2.5kV 5kV 10kV 20kV Measurement voltage accuracy ±(5% 10V) Short circuit current 10mA Measurement range and accuracy Measurement range Resistance measurement range Accuracy 20M 0.01 19.99M ±(5%+3d) 200M 5.0 199.9M ±(5%+3d) 2000M 50-1999M ±(5%+3d) 20G 0.5-19.99G ±(5%+3d) 200G 5.0-199.9G ±(10%+3d) 2000G 50-1999G ±(20%+10d)
Product description Transformer oil flash point tester is used to determine the flash point value of petroleum products. The instrument adopts electric ignition mode without any flammable gas and meets the requirements of GB3536-2008 and GB267-88. Moreover, it utilizes many kinds of latest technologies such as ARM series high-performance microprocessor, electric erasing memory (can store thousands of data records), 7-inch color liquid crystal display and touch screen and PID self-tuning, etc. Technical index Test range: 40~400 Test type: Open flash point Temperature detection: Platinum resistance Accuracy: ±1 Repeatability: Meet GB3536-2008 and GB/T 267-88 Display: 7-inch touch screen and colorful LCD Information storage: 1000 test results can be stored Ignition method: Electronic ignition Cooling method: Forced air cooling Atmospheric pressure: Automatic detection of atmospheric pressure, automatic correction of test results Printer: Dot matrix thermal printer Self-check function: Lift lever, scratch lever, printing, etc. Power: 600VA Power supply: (AC) 220V ±11V frequency: 50Hz ±2.5Hz Ambient temperature:10~35 Ambient humidity: 90% Packaging weight: about 17kg
Product description To satisfy the requirement for quick measurement of DC resistance of transformer, our Company has developed three-channel, DC resistance tester aiming at YN connection winding. The tester can fulfill functions such as simultaneous energization on three phases, independent current sampling, voltage sampling, as well as simultaneous measurement and display of three-phase resistance value and three-phase unbalance rate, thus can significantly reduce test time for DC resistance of transformer, solve the problem of long test duration for DC resistance of each tapped winding of electric power transformer. It requires only 1/3 of the time required by traditional method Technical index 1. Output current: select current automatically (maximum 20 A) 2. Range ability: 0-100 3. Accuracy: 0.2% ±20-100 4. Minimum resolution: 0.1 5. Working temperature: -20-40 6. Ambient humidity: 80%RH, no condensation 7. Working power supply: AC220 V ±10%, 50 Hz±1 Hz 8. Volume: L 400 mm*W 340 mm*H 195 mm 9. Net weight: 8 kg
Product description The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of useï¼? Measurement accuracy: voltage, current: 0.2 level Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Voltage measurement range: AC 3V300V Internal power output range: voltage 0~250V, current 0~10A Current measurement range: AC 0.2A 20A Working temperature: -10-50 Working humidity: 0-80% Working power supply: AC220V 10-50Hz1Hz Dimensions: 360mm-220mm 150mm Weight of the instrument: 20Kg
product description Oil trace moisture tester This instrument is able to work more reliably and conveniently by using the most advanced control circuit and 32 bit embedded microcontroller processor as the master control core and utilizing embedded mini operating system. Oil trace moisture tester (2) Technical index: Titration method Coulometric titration Coulomb analysis Display Color LCD touch screen Electrolytic current control 0 400mA automatic control Measurement scope 3ug 100mg Sensitive valve 0.1 µg H2O Accuracy 10 µg 1000 µg ±3 µg More than 1mg but not greater than 0.3% Printer Miniature thermal printer Power supply 220V ±10% 50Hz Power 40W Ambient temperature 5 40 Ambient humidity 85% External dimension 340 295 155 Weight About 5.5kg
1. Wide range of measuring voltage can test up to 1000G (Max 2000G) insulation resistance 2. Three and a half bit LCD digital display of insulation resistance value 3. automatically shift resistance measuring range 4. environment temperature can be measured 5. self-clocking function short buzz every 15 seconds 6. automatically calculate and save R15S R60S R600S DAR and Polarization Index 7. Output short-circuit current larger than 5mA (meet fast charging request to capacitive load) 8. strong anti-interference ability stable and reliable reading 9. perfect protection safe for operation 10. powered by rechargeable Li-battery auto power off when battery energy is not enough
This instrument is carefully designed and developed by the relevant technical personnel of our company according to the needs of power users. The product is beautiful in appearance and easy to carry and use. It replaces the traditional bulky test instruments and test methods and is very popular among professionals. 1. Small size and light weight. 2. The measurement process is safe and fast and the measurement result is accurate.
This instrument is carefully designed and developed by the relevant technical personnel of our company according to the needs of power users. The product is beautiful in appearance and easy to carry and use. It replaces the traditional bulky test instruments and test methods and is very popular among professionals. 1. Small size and light weight. 2. The measurement process is safe and fast and the measurement result is accurate.