Product description
Partial discharge test system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities.
Technical Parameters:
Rated Capacity
5-1000kVA
Impedance Voltage
10%
Input Voltage
AC 220V/AC 380V
Output Voltage Waveform
Power frequency sine wave
Output Voltage
AC 0-1000kV
Surface Temperature
Oil immersed:
Product Introduction YDW series PD tester system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities. product features Product Characteristics A variety of control methods and insulation methods can be used to configure freely according to user demand. Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi- frequency power generator which can be used to measure the discharge of high voltage transformer. Manual control operation is intuitive easy to use maintenance low price. It has gas insulation transformer oil insulation dry epoxy resin insulation and other forms test transformer can choose and match according to user's demand. According to the user's requirements different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults. Automatic control system can be used in different configurations of the bureau and the results can be automatically detected and analyzed.
Product Introduction YDW series PD tester system is mainly used for testing frequency voltage insulation level of various insulation materials insulation structure and electrical products also as partial discharge frequency testing power supply for testing object such as transformer mutual inductor and lightning arresters. It widely used in electrical manufacturing power operation departments research institutes and universities. product features Product Characteristics A variety of control methods and insulation methods can be used to configure freely according to user demand. Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi-frequency power generator which can be used to measure the discharge of high voltage transformer. Manual control operation is intuitively easy to use maintenance low price. It has gas insulation transformer oil insulation dry epoxy resin insulation and other forms test transformer can choose and match according to user's demand. According to the user's requirements, different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults. An automatic control system can be used in different configurations of the bureau and the results can be automatically detected and analyzed.
Product description Partial discharge inspection instrument is a digital partial discharge charged detection instrument designed by our company based on years of experience in partial discharge measurement. It adopts two emerging technologies, ultra high frequency (UHF) measurement and ultrasonic (US) measurement. This system uses modern electronic and computer integrated technology to realize signal amplification, filtering, data acquisition, data processing, partial discharge parameter calculation, map drawing, and automatic generation of test reports, thereby completing the intelligent measurement and analysis of partial discharge. This device adopts handheld design and Wince system development; the device is lightweight, convenient to carry, fast to measure, and easy to use on the spot; it has friendly interface, simple operation, and high refresh rate; and the device has complete functions, strong anti-interference ability, and accurate measurement. This instrument has no damage to the power equipment to be tested during the testing process, and has no impact on the operation of the equipment. According to the maps obtained by the multiple detection modes of the UHF and US methods, the diagnostic analysis of the detection of insulation defects or hidden dangers of power equipment can be performed to clearly determine the operating status of the power equipment. Technical index Host parameters Number of interfaces 2 interfaces 1 UHF interface 1 US interface Sampling accuracy 12bit Way of synchronization Internal synchronization,External synchronization, Light synchronization UHF parameters Measurement frequency range 300MHz-1.5GHz Output method Output with SMA head Receiving method Receive with antenna Transfer method Coaxial cable Sensitivity 70dB Mean sensitivity 50dB Dynamic Range 80dB Hardware Display screen 4.3 TFT true color LCD screen Resolution 480 272
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy.
Ethanol alcohol distillation column 1. It is standard 95-96% alcohol equipment. Also it can distill pure water. 2.The distillation system has  three columns  and  continuous  distillation  process.The process is the  same as industrial(large scale) alcohol equipment.  Mash distillation  column distills  fermented  mash or light alcohol  to 50% alcohol ethanol . It has red copper bubble cap trays, standard design. It auto continuously feeds material liquid, auto continuously produces 50% alcohol ethanol and auto continuously discharges waste,  ethanol discharge in waste 0.05%, better than international standard requirements. The first rectification distillation  column  increases  alcohol degree  to 70-75% ,  separates  fusel oil and high boiling point  Impurities.  It auto discharges waste water,  ethanol discharge in waste 0.05%, better than international standard requirements. The second rectification distillation  column  increases alcohol degree to 95%,  separates low boiling point  impurities  like acetaldehyde and methanol . 3.  The rectification system uses  industrial(large scale) standard process, but the whole set alcohol equipments are installed in one frame, like integration  module, even  you can run it by a button.
Distillation column For Ethanol Alcohol Plant 1. It is standard 95-96% alcohol equipment. Also it can distill pure water. 2. The distillation system has three columns and continuous distillation process.The process is the same as industrial(large scale) alcohol equipment.     a. Mash distillation column distills fermented mash or light alcohol to 50% alcohol ethanol .  It has red copper bubble cap trays, standard design. It auto continuously feeds material liquid, auto continuously produces 50% alcohol ethanol and auto continuously discharges waste, ethanol discharge in waste ?¤0.05%, better than international standard requirements.     b. The first rectification distillation column increases alcohol degree to 70-75% , separates fusel oil and high boiling point Impurities. It auto discharges waste water, ethanol discharge in waste ?¤0.05%, better than international standard requirements.     c. The second rectification distillation column increases alcohol degree to 95%, separates low boiling point impurities like acetaldehyde and methanol . 3.  The rectification system uses  industrial(large scale) standard process, but the whole set alcohol equipments are installed in one frame, like integration module, even you can run it by a button.
Product description Digital detector partial discharge test and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. Echnical parameter Number of channels: 4 independent measurement channels (scalable) and 1 external trigger input channel. Sampling rate: 200MSa / s Sampling accuracy: 12bit Host Screen size: 6.5 inches Operation: mouse keyboard touch screen Host interface: 2 USB ports 1 Ethernet port 1 VGA port. Synchronous Frequency range: 30Hz ~ 1MHz Power Mode: Built-in lithium battery or external AC power supply (AC220V 50Hz) Measurement content: Discharge magnitude (Q) the discharge phase (?) the discharge density (N) Data processing sampling period: 1s 3 amplitude-time a relationshipmagnitude-phase relationship number of discharges-phase relationship Charging power supply: AC220V; 50Hz frequency System design life: more than 10 years
Product Introduction Digital PD Detector Partial Discharge Testing Digital PD Detector Partial Discharge Testing Product Overview The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy. product features Product Characteristics Digital PD Detector Partial Discharge Testing Working Condition Altitude 3000m Environmental Temperature -20~60C Relative Humidity 95%
Product description 120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90) Technique Index 1. power: AC220V+10%, 50Hz+1% 2. Output voltage indicator accuracy: