Sending Inquiry For: Transformer Oil Dielectric Strength Tester

Aug-05-21

Transformer Oil Dielectric Strength Tester

$770 - $15.40K
MOQ: Not Specified
Wuhan, Survive, China
 
Overview

Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB/T507-2002, industry standard DL429.9-91 and the latest Electric Power Industry Standard DL/T846.7-2004 by ourselves. This instrument, by using a single-chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.

Major Technical Indicators
1. Output voltage: 0-100KV (optional)

2. Voltage distortion rate: 3%

3. Voltage raising speed: 0.5-5 KV/S (adjustable)

4. Standing time: 15min (adjustable)

5. Boosting interval: 5 min (adjustable)

6.Boosting frequency: 1-9 time(s) (optional)

7. Booster capacity: 1.5KVA

8.Measuring accuracy: ±3

9. Supply voltage: AC220V ±10%

50Hz±1 Hz

10. Power: 200W

11.Applicable temperature: 0-45

12.Applicable humidity: 75%RH

13. Overall dimension: 465 385 425