Product description
Digital detector partial discharge test and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge.
Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer.
Echnical parameter
Number of channels: 4 independent measurement channels (scalable) and 1 external trigger input channel.
Sampling rate: 200MSa / s
Sampling accuracy: 12bit
Host Screen size: 6.5 inches
Operation: mouse keyboard touch screen
Host interface: 2 USB ports 1 Ethernet port 1 VGA port.
Synchronous Frequency range: 30Hz ~ 1MHz
Power Mode: Built-in lithium battery or external AC power supply (AC220V 50Hz)
Measurement content: Discharge magnitude (Q) the discharge phase (?) the discharge density (N)
Data processing sampling period: 1s
3 amplitude-time a relationshipmagnitude-phase relationship number of discharges-phase relationship
Charging power supply: AC220V; 50Hz frequency
System design life: more than 10 years
Product Introduction Digital PD Detector Partial Discharge Testing Digital PD Detector Partial Discharge Testing Product Overview The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy. product features Product Characteristics Digital PD Detector Partial Discharge Testing Working Condition Altitude 3000m Environmental Temperature -20~60C Relative Humidity 95%
Product Introduction Digital PD Detector Partial Discharge Testing Digital PD Detector Partial Discharge Testing Product Overview The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy. product features Product Characteristics Digital PD Detector Partial Discharge Testing Working Condition Altitude 3000m Environmental Temperature -20~60C Relative Humidity 95%
Product Introduction Digital PD Detector Partial Discharge Testing Digital PD Detector Partial Discharge Testing Product Overview The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and measurement accuracy. product features Product Characteristics Digital PD Detector Partial Discharge Testing Working Condition Altitude3000m Environmental Temperature -20~60°C Relative Humidity 95%
Commodity: Sodium Hydrosulfite Other name: Synonyms: Sodium Hydrosulphite; Sodium Dithionite; Dithionous acid, Disodium salt; Sodium Sulfoxylate CAS No.: 7775-14-6 Molecular Weight: 174.10 Chemical Formula: Na2S2O4 Product Description Appearance: White, crystalline powder. Product Feature Odor: Slight irritative. Specific Gravity: Unavailable Solubility: Soluble in water. Density: 2.19 pH: 6-7 pH Test-Method: PH test paper. % Volatiles by volume @ 21C (70F): 0 Boiling Point: Not applicable. Melting Point: >300 C Decomposes. Vapor Pressure (mm Hg): No information found. Bulk Density: ~0.9 Evaporation Rate (BuAc=1): No information found. Application 1. Widely used in textile industry for vat dyeing, reduction cleaning, printing and stripping, textile textile bleaching . 2. bleaching paper pulps , especially mechanical pulps, its the most fittable bleaching agent in pulps. 3. bleaching kaolin clay, fur bleaching and reductive whitening, bleaching of bamboo products and straw products, 4. in mineral, the compound of thiourea and other sulphides. 5. as reducing agent in chemical industry. 6. Sodium hydrosulfite food additive grade is used in foodstuffs, as bleaching agent and preservative dried fruits, dried vegetable, vermicelli, glucose, sugar, rock sugar, caramel, candy, liquid glucose, bamboo shoots, mushrooms and canned mushrooms. Packaging 50kg/100kg net in iron drums with double PVC bags Product Specification/Models NDEX 90%, 88%, 85%. FOOD ADDITIVE Na2S2O4, 90%, 88%, 85%, Fe 20ppm ZincZnOther heavy metal calculated as Pb, 1ppm Water Insolubles05% Shelf Life(month)12
Commodity: Sodium Bisulfite Molecular Formula: NaHSO3 Molecular Weight: 104.06 Properties: White monoclinic crystalline powder with sulfur dioxide odor; relative density: 1.49; very easily soluble in water; can be decomposed when heated; slightly soluble in ethanol; aqueous solution is acidic; has strong reducing property; can be oxidized in the air or loose sulfur dioxide. Quality Standard: HG/T3492-80 Technical Indicator High-purity grade Acrylic grade Food grade Refined grade Industrial grade 1 NaHSO3 % 99.5 Insol. in water % 0.003, 0.005, 0.03, 0.04, 0.05 Chloride(Cl) % 0.003, 0.004 Iron(Fe) % 0.001 0.002 0.005 Heavy metal(Pb) 0.001 Arsenic(As) % 0.0001 Clarity test Qualified Use: It is used in the bleaching of cotton textiles; as reducing agent in dyes, paper-making, leather, chemical synthesis; in the manufacture of pharmaceutical intermediates, developer, food bleacher, antiseptic and anti-oxidants. Packing: In PP woven bag lined with PE bag; paper-plastic composite bag, and kraft paper bag etc. Net wt.: 25/50/1000 kgs/bag or upon clients' request.
Commodity: Ammonium bicarbonate Food grade Molecular formula:NH4HCO3 Molecule Weight: 79.05 H.S code: 2836994000 CAS: 1066-33-7 Product Physical Properties WHITE POWDER CRYSTAL, SPECIFIC GRAVITY IS 1.586, IT CANDISSOLVE IN WATER, BUT CANT DISSOLVE IN ALCOHOL AND ACETINE. Specifications: Appearance: white free-flowing crystalline powder without agglomeration Purity as Ammonium Bicarbonate ,% by weight 99.5 (minimum) Chloride (as Cl), % by weight 0.20(maximum) Sulphates (as SO4),% by weight 0.10(maximum) Iron (as Fe), % by weight 0.004(maximum) Nonvolatile matter, % by weight 0.10(maximum) Heavy metals (as Pb), ppm 2.50(maximum) Copper (as Cu), ppm 5.0(maximum) Arsenic (as As), ppm 0.6(maximum) Tarry matter To pass test Oil Content Less than 10 ppm Melamine Content NIL USAGE BAKING FOODS SUCH AS CRISP CAKE, BISCUIT ETC. IN ADDITION, ITALSO WIDELY USED IN CHEMICAL FIELD SUCH AS FLOUR BRIGHTENING AGENT,RARE EARTH DEEP PROCESSING, MEDICINE MIDBODY, PLASTICS PROCESSING,ELECTRONIC ELEMENT ETC. PACKING OUTSIDE IS WEAVE BAG OR PAPER BAG, INSIDE IS FOOD PLASTICSBAG, 25KG/BAG. THE PACKING ALSO CAN ACCORDING TO CONSUMERS REQUEST. STORAGE Stored in a cool, ventilated, dry place.
Ethanol alcohol distillation column 1. It is standard 95-96% alcohol equipment. Also it can distill pure water. 2.The distillation system has  three columns  and  continuous  distillation  process.The process is the  same as industrial(large scale) alcohol equipment.  Mash distillation  column distills  fermented  mash or light alcohol  to 50% alcohol ethanol . It has red copper bubble cap trays, standard design. It auto continuously feeds material liquid, auto continuously produces 50% alcohol ethanol and auto continuously discharges waste,  ethanol discharge in waste 0.05%, better than international standard requirements. The first rectification distillation  column  increases  alcohol degree  to 70-75% ,  separates  fusel oil and high boiling point  Impurities.  It auto discharges waste water,  ethanol discharge in waste 0.05%, better than international standard requirements. The second rectification distillation  column  increases alcohol degree to 95%,  separates low boiling point  impurities  like acetaldehyde and methanol . 3.  The rectification system uses  industrial(large scale) standard process, but the whole set alcohol equipments are installed in one frame, like integration  module, even  you can run it by a button.
Distillation column For Ethanol Alcohol Plant 1. It is standard 95-96% alcohol equipment. Also it can distill pure water. 2. The distillation system has three columns and continuous distillation process.The process is the same as industrial(large scale) alcohol equipment.     a. Mash distillation column distills fermented mash or light alcohol to 50% alcohol ethanol .  It has red copper bubble cap trays, standard design. It auto continuously feeds material liquid, auto continuously produces 50% alcohol ethanol and auto continuously discharges waste, ethanol discharge in waste ?¤0.05%, better than international standard requirements.     b. The first rectification distillation column increases alcohol degree to 70-75% , separates fusel oil and high boiling point Impurities. It auto discharges waste water, ethanol discharge in waste ?¤0.05%, better than international standard requirements.     c. The second rectification distillation column increases alcohol degree to 95%, separates low boiling point impurities like acetaldehyde and methanol . 3.  The rectification system uses  industrial(large scale) standard process, but the whole set alcohol equipments are installed in one frame, like integration module, even you can run it by a button.