Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60;
Product Usage The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station. Product function JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 14, 55; Strengthen the contact gap: not less than 7mm; Ordinary contact gap: not less than 4.5mm; Reinforce the gap of the support plate: generally not less than 0.35mm; Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;
Product Usage The JWJXC2-6800 type enhanced contact relay is used in the distributed power supply screen. Product function It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. test method Standard test conditions Temperature: +15â??~+45â??; Relative humidity: 45%~75% Air pressure: 86kPa~106kPa Requirements for testing measuring tools, meters, and power supply The accuracy of the measuring tool for measuring appearance and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%. The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1. The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz. Mechanical properties
Product Usage The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 2DF, 2DFJ; Identification pin number: 15, 54; Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm; Pallet gap: ordinary contact point is not less than 0.35mm; Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN; Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN; Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm. Positioning or reverse position holding force is not less than 4N;
product description JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Product Introduction The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Product Introduction The JWJXC-135/135 stepless enhanced relay is an important element in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product function It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Product Usage JWJXC-135/135. Infinitely enhanced relays (hereinafter referred to as relays) are used as general relays in signal circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40â??~+60â??; b) Relative humidity: not more than 90% (temperature +25�°C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Insulation withstand voltage Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.
Product Introduction JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section. Features 1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Installation Precautions 1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing. 2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging. 3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Product electrical life The relay contact is connected to DC24V1A resistive load; its electrical life is 1106 times
product description Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JZXC-480F lightning protection rectifier relay is used as AC track and AC accident relay in signal circuit. Product function It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment a) Ambient temperature: -40â??~+60â??; b) Relative humidity: not more than 90% (temperature +25�°C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; 2Q Identification pin number: 13, 55; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm.
Product Usage The JZJXC-100 type rectifier strengthened contact relay is used as a power supply supervisory relay for the indicator light in the power supply screen. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25C); C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 22, 32; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 7mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic breaking contact is not less than 200mN; Strengthen the contact pressure: the moving and closing contact is not less than 600mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC24V Magnetizing value: AC24V Release value: not less than AC4V Working value: not more than AC11V Coil resistance: 50 (1±10%) Q2 Coils are connected in series, connect 2, 3, use 1, 4
Product Introduction JPXC-1000 biased pole relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JPXC-1000 biased pole relay is designed to identify the polarity of the current in the signal circuit. In the signal circuit, it is used in the turnout indication circuit and the single-multiplex semi-automatic blocking circuit. Features 1. The relay adds a pole-biased magnet to the magnetic circuit, so that the armature is biased to the drop position by the permanent magnetic force. The pull-up of the armature is related to the polarity of the current in the coil. When the current through the coil is in the specified direction, the armature is pulled up, and when the direction of the current is opposite, the armature remains stationary. It only has a stable state, that is, after the armature is sucked up by electromagnetic force, it will fall when the power is cut off, and it will always be in a falling positioning state. 2. The relay is a heavy spring force DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is powered off. 3. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 5. The relay contact system is composed of ordinary contacts, with 8 groups of ordinary moving on and moving off conversion contacts. 6. The rated voltage of the relay is DC 24V.
Product Introduction JZXC-16/16 is a dedicated multiplexer used to close and open the signal control circuit. It is an important part of railway signals. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. Product Features The JZXC-16/16 (formerly known as JZXC-16F) rectifier relay has a high return coefficient, which is used to automatically block the signal lighting circuit of the interval and solve the problem of large leakage current in long-distance power supply cables and unreliable release of the filament supervision relay. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The front ring of the relay is a diode-enclosed short-circuit coil, without a rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. 6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the sp
Product Introduction The JZXC-H18F rectifier slow release relay is an important component in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage The JZXC-H18F rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay. 4. The relay is a new product improved on the basis of the JZXC-H18 rectifier relay. The relay has no rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. The wiring terminal of the relay is exactly the same as the JZXC-H18 rectifier relay, so it is interchangeable, and there is no need to change the wiring on site. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. 6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.
Product Introduction JZXC-H0.14/0.14 rectifier slow release relay is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Features The JZXC-H0.14/0.14 rectifier slow release relay is used as a filament conversion relay in the signal lighting circuit of a crossing. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Features
Product Features The JZXC-H18F1 (formerly JJXC-H15) type rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Applicable environment a) Ambient temperature: 40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Features 1. The relay is a heavy spring force DC electromagnetic relay, which uses the principle of constant gravity to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver oxidized vehicle contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual current, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay. 4. The relay is a new product improved on the basis of the JJXC-15 filament relay. The relay has no rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. The wiring terminal of the relay is exactly the same as the JUXC-15 filament relay, so it is completely interchangeable, and there is no need to change the wiring on site. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. 6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.
Product Features The JZXC-20000 rectifier relay is used as a buck-boost control relay in the power supply screen; as a signal channel and track power supervision relay; and a conversion relay between the main screen and the backup screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Features 1. The relay is an AC 220V heavy elastic rectifier electromagnetic relay, which adopts the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The relay consists of two parts: a rectifier circuit and a non-polar relay. The rectifier circuit is a bridge rectifier circuit composed of four 1N4007 silicon rectifier diodes. The input of the rectifier is alternating current, and the rectified current output to the coil is direct current. 5. The relay contact system is composed of common contacts, with six groups of common contacts for switching on and off. Mechanical properties Number of contact groups: 6QH; Identification pin number: 23, 55; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rated value: AC220V Magnetizing value: AC220V Release value: not less than AC 35V Working value: not more than AC105V Coil resistance: 10000 (1±10%) Q2 coils in series, connect 1, 4, use 7, 8; time characteristics (At rated voltage): The pull-in time is not more than 01S, and the slow release time is not more than 0.15
Product Usage The JZJXC-7200 rectifier enhanced contact relay is used as a reversible motor control relay in the power supply screen. Features 1. The JZJXC-7200 and JZJXC-100 relays are AC 220V, AC 24V heavy-elasticity reinforced contact rectifier electromagnetic relays, adopting the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The magnetic circuit system of the relay is basically the same as the JWJXC-7200 stepless enhanced contact relay. 5. The contact system is composed of two parts: ordinary contacts and reinforced contacts. There are two groups of moving and breaking ordinary contacts; four groups of moving and closing reinforced contacts without arc extinguishing magnets. The structure of ordinary contacts is the same as that of non-polar relays. The reinforced contacts are specially designed. Of high-power contacts. 6. The relay has a rectifier unit attached to it because there is no place to install the rectifier unit on the contact group. The rectifier unit is a full-wave rectifier composed of four 1N4007 silicon rectifier diodes. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Product Introduction Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. The JZXC-H62 rectifier slow release relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage JZXC-H62 type rectifier slow release relay is used in signal circuit for turnout display circuit and single-multi-line semi-automatic blocking circuit. Features JZXC-H62 rectifier slow release relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment. Product function The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); C) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Executive standard Q/SX0410.06-2012 "AX Series Relay" Product Features Mechanical properties Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm.
Product Introduction JZXC-H142 type rectifier slow release relay is an important component in interlocking equipment. It is the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product function JZXC-H142 rectifier slow release relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Product Usage The JZXC-H142 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.