Product Introduction
The JWJXC-135/135 stepless enhanced relay is an important element in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.
Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.
Product function
It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.
Product Usage
JWJXC-135/135. Infinitely enhanced relays (hereinafter referred to as relays) are used as general relays in signal circuits.
Applicable environment
The applicable environment of the relay is:
a) Ambient temperature: -40â??~+60â??;
b) Relative humidity: not more than 90% (temperature +25�°C);
c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);
d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;
e) Working position: horizontal;
f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Insulation withstand voltage
Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.
Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.
Product Usage The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station. Product function JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 14, 55; Strengthen the contact gap: not less than 7mm; Ordinary contact gap: not less than 4.5mm; Reinforce the gap of the support plate: generally not less than 0.35mm; Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;
Product Introduction The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Structural characteristics Mechanical properties Number of contact groups: 2QH, 2QJ, 2H; Identification pin number: 15, 55; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 2.5mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic closing or positioning contact not less than 150mN; dynamic breaking or reverse position contact not less than 150mN; Strengthen the contact pressure: the dynamic closing or positioning contact is not less than 400mN; the dynamic breaking or reverse position contact is not less than 300mN; Contact uniformity error: not more than 0.20mm.
Supplier: Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment.
Services: We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Buyer: Industrial electrical parts
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Product Usage The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 2DF, 2DFJ; Identification pin number: 15, 54; Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm; Pallet gap: ordinary contact point is not less than 0.35mm; Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN; Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN; Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm. Positioning or reverse position holding force is not less than 4N;
Supplier: Labels, carton boxes, books, metalized printing, printed materials, electronic components, parts, panels, note book printing, text book printing, cake box,groundnut oil
Buyer: ,
Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60;
The Variable Speed Drive FRENIC series is equipped with functions and performance to meet all types of requirements, and in addition it is easily maintained and environmentally friendly. The series lineup ranges from simple to advanced-function models, enabling model choices matching situations for use. Fuji Electric provide Variable Speed Drives perfect for automating and with energy saving devices like a fan pump or carrier and variable speeds.