Winner2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
Winner2309A is intelligent full automatic laser particle size analyzer, adopt the most advanced International MIE scattering principle and Fraunhofer diffraction principle, which is integrated model of wet and dry dispersion system, High sensitive and High-resolution photoelectric probe system and imported Canon lens optical path ensure the good accuracy and repeatability of particle size distribution, It s widely used in industrial production quality control departments and research institutions.
Test range:0.01-2000 microns
Product Description
Winner2005B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1�¼m to 1000�¼m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles.
Specification
Model Name
Winner2005B
Standard
ISO13320-1:1999ï¼?GB/T19077.1-2008ï¼?Q/0100JWN001-2013
Principle
MIE Scattering Principle
Size range
0.1�¼m-1000�¼m
Photodetectos
87 pcs
Accuracy
â?¤0.5% (Deviation of D50 on national standard sample)
Repeatability
â?¤0.5% (Deviation of D50 on national standard sample)
Laser
Semi conductor Laser �»= 636.5nm, p>2mW
Service time>25000 hour
Wet dispersion
Ultrasonic
Frequency:40KHz Power:35W, Time: â?¥1S
Agitator
Revolutions Speed: 0-3000RPM (Adjustable)
Circulation
Rated Flow:8L/min Rated Power:10W
Sample tank
Volume: 350mL
Operation mode
Manual and Full automatic
Optical alignment system
Full automatic optical path alignment system
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Report Items
Particle size distribution table&graph, average diameter, Median diameter, SSA, etc.
Testing speed
Product Description
Winner3008B is intelligent dry laser particle size analyzer, manual and full automatic operation model. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.
It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. Itâ??s fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, Itâ??s with the same accuracy and repeatability.
Main Features
(1) Advanced testing optical path.
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.
(2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion systemâ??s working life.
(3)Human-based operation mode Manual and Full automatic, easy choose.
(4)High precision-automatic optical path calibration system
Itâ??s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.
(5)Intelligent data analysis-winner unique software support
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.
(6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).
(7)Users can design the test report output and display forms according to industry requirements.
Specification
Model
Winner3008B
Standard
ISO 13320-1:1999ï¼?GB/T19077.1-2308ï¼?Q/0100JWN001-2013
Measuring Range
0.1-2000�¼m/0.1-1200�¼m
Channels Number
100/97pcs
Accuracy
Product Description
Winner2005A intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1m to 1000m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles.
Specification
Model Name
Winner2005A
Standard
ISO13320-1:1999 GB/T19077.1-2008 Q/0100JWN001-2013
Principle
MIE Scattering Principle
Size range
0.01�¼m-1000�¼m
Photodetectos
90pcs
Accuracy
â?¤0.5% (Deviation of D50 on national standard sample)
Repeatability
â?¤0.5% (Deviation of D50 on national standard sample)
Laser
Semi conductor Laser �»= 636.5nm, p>2mW
Service time>25000 hour
Wet dispersion
Ultrasonic
Frequency:40KHz Power:35W, Time: â?¥1S
Agitator
Revolutions Speed: 0-3000RPM (Adjustable)
Circulation
Rated Flow:8L/min Rated Power:10W
Sample tank
Volume: 350mL
Operation mode
Manual and Full automatic
Optical alignment system
Full automatic optical path alignment system
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Report Items
Particle size distribution table&graph, average diameter, Median diameter, SSA, etc.
Testing speed
Product Description
Winner3009B intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.
It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials,especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It' with the same accuracy and repeatability.
Main Features
(1) Advanced testing optical path.
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.
(2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion systemâ??s working life.
(3)Human-based operation mode Manual and Full automatic, easy choose.
(4)High precision-automatic optical path calibration system
Itâ??s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.
(5)Intelligent data analysis-winner unique software support
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.
(6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).
(7)Users can design the test report output and display forms according to industry requirements.
Specification
Model
Winner3009B
Standard
ISO 13320-1:1999ï¼?GB/T19077.1-2308ï¼?Q/0100JWN001-2013
Measuring Range
0.1-1200m
Channels Number
97pcs
Accuracy
Product Description
Winner2000ZD intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
Model Name
Winner2000ZD
Standard
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle
MIE scattering principle
Measuring Range
0.1-40�¼m/0.6-120�¼m/1-300�¼m
Channels Number
76*3 pcs
Accuracy error
25000hour
Dispersion
Method
Ultrasonic
Frequency:40KHz Power:35W, Time: â?¥1S
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic and manual control, freely choose
Output parameter
D10,D50,D90,D100,S/V referent parameters
Optical Calibration System
Full automatic
Test Speed
Product Description
Winner2006B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01�¼m to 1000�¼m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data.
Main Features
(1)Unique Converging Light Fourier Transform Light Path, For better to test sub-micron particles, Adopt orthogonal double laserbeam patented technology, measure range expanded from 0.01/0.1�¼m-1000�¼m.
(2)Intelligent operation mode realize one key test, automatically supply-water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.
(3) Automatic optical light alignment system is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make light path be always in a good state.
(4)Liquid sample dispersion/preparation system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.
(5)Software support: Original patent unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
(6) Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )
Specification
Model Name
Winner2006B
Standard
ISO13320-1:1999,GB/T19077.1-2008ï¼?Q/0100JWN001-2013
Principle
MIE scattering theory
Size range
0.1 m-1000 m
Detector Channels
87 pcs
Accuracy error
Product Description
Winner2006A intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01m to 100m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data. It enables you understand materials well, such as abrasives,adhesives, agrochemical,barite, Batteries, Bentonite,
Main Features
(1) The laser particle size analyzer adopts a unique concentrated Fourier transform optical path. In order to better test sub-micron particles, it adopts the patented technology of orthogonal dual laser beams, and the measurement range is extended from 0.01/0.1�¼m-1000�¼m.
(2) The intelligent operation mode realizes one-click testing, automatic water replenishment, ultrasonic dispersion, circulation, and drainage, which not only reduces the workload, but also achieves better repeatability after eliminating human factor errors.
(3) The laser particle size analyzer adopts an automatic optical alignment system composed of a precision four-phase hybrid stepper motor. Its micro-movement accuracy reaches the micron level, so that the optical path is always in good condition.
(4) Laser particle size analyzer configuration Liquid sample dispersion/preparation system: fully built-in mechanical stirring, ultrasonic dispersion, and circulation paths are integrated, and the high-power circulation pump and pipeline are optimized to effectively prevent the precipitation of large particles.
(5) Software support: Original patented unconstrained free fitting technology enables particle analysis without any functional restrictions and truly reflects particle distribution.
(6) Output parameters: (D50, D03, D06, D10, D16, D25, D75, D84, D90, D97, D98, set any value, S/V, D[3,2], D[4,3 ] )
Specification
Model Name
Winner2006A
Standard
ISO13320-1:1999,GB/T19077.1-2008ï¼?Q/0100JWN001-2013
Principle
MIE scattering theory
Size range
0.o1m-1000m
Detector Channels
90pcs
Accuracy error
Product Description
Winner2008A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Specification
Model Name
Winner2008A
Standard
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle
MIE scattering principle
Measuring Range
0.01�¼m-2000�¼m
Channels Number
127
Accuracy error
â?¤0.5% (Deviation of D50 on national standard sample)
Repeatability error
â?¤0.5% (Deviation of D50 on national standard sample )
Light source
High performance He-Ne Laser (�»= 632.8nm, P>2MW)
Lifetime>25000hours
Dispersion
Method
Ultrasonic
Frequency:40KHz Power:35W, Time: â?¥1S ,Anti-dry function
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic/ manual control, freely choose
Resolution
Free distribution truly reflect particle size distribution
Optical bench alignment system
Japan Canon lens, Full automatic,precision is up to 0.1um
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Testing speed
Product Description
Winner2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200�¼m/2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Product Description
Winner3006 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Winner2308B intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200m/2000m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Winner 2309B Sizing Laser Ink Image Dry And Wet Particle Size Granulometer Tester Analyzer is intelligent full automatic laser particle size analyzer,adopt MIE scattering principle, which is integrated model of wet and dry dispersion system. Itâ??s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.
Winner311PRO is a new generation desktop spray particle size analyzer designed and developed mainly for droplet particle size testing of small spray equipment. Based on Winner311XP, it incorporates more unique micro-nano technologies, innovative design of external automatic mobile platform, optical path The design is more optimized, the detection channels are wider distributed, the algorithm is more stable, and the application is more intelligent.
Winner311PRO can perform non-contact particle size measurement of droplets, liquid droplets, smoke, aerosol, powder mist, etc. dispersed in the air, and meets the requirements for particle size testing of inhaled aerosols, sprays, powder mist, etc. specified in the National Pharmacopoeia. , filling the gap of domestic laser particle size analyzer in measuring droplet size of small atomization devices.
Winner319A Industrial Spray Particle Size Analyzer
Winner319A is a desktop spray laser particle size analyzer specially designed and developed for droplet size testing. The instrument adopts the principle of Fraunhofer diffraction and the parallel optical path design of high-performance and high-power lasers, which can meet the requirements of droplet testing. And the test range can be adjusted according to customer requirements.
Product Description
Winner2008Awet laser particle size analyzer measure size is from 0.01 to 1200 micron, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multi-spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Parameter
Model Name
Winner2008A
Standard
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle
MIE scattering principle
Measuring Range
0.01�?�¼m-2000�?�¼m
0.01�?�¼m-1200�?�¼m
Channels Number
127
Accuracy error
25000hours
Dispersion
Method
Ultrasonic
Frequency:40KHz Power:35W, Time: �¢?�¥1S ,Anti-dry function
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic/ manual control, freely choose
Resolution
Free distribution truly reflect particle size distribution
Optical bench alignment system
Japan Canon lens, Full automatic,precision is up to 0.1um
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Testing speed
Product Description
Winner3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
Specification
Model Name
Winner3003
Size Range
0.1�?�¼m-300�?�¼m
Standard
ISO13320-1:1999 GB/T19077.1-2008 Q/0100JWN001-2013
Channels Number
40 pcs
Accuracy error
Product Description
Winner3008A is intelligent dry laser particle size analyzer, manual and full automatic operation model. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.
It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability.
Specification
Model
Winner3008A
Standard
ISO 13320-1:1999 GB/T19077.1-2308Q/0100JWN001-2013
Measuring Range
0.1-2000m/0.1-1200m
Channels Number
100/97pcs
Accuracy
Product Description
Winner3009A intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.
It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials,especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability.
Main Features
(1) Advanced testing optical path.
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.
(2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system's working life.
(3)Human-based operation mode Manual and Full automatic, easy choose.
(4)High precision-automatic optical path calibration system
It's composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.
(5)Intelligent data analysis-winner unique software support
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.
(6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).
(7)Users can design the test report output and display forms according to industry requirements.
Specification
Model
Winner3009A
Standard
ISO 13320-1:1999 GB/T19077.1-2308 Q/0100JWN001-2013
Measuring Range
0.1-2000m
Channels Number
100 pcs
Accuracy
Product Description
Winner2008B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Specification
Model Name
Winner2018
Standard
ISO13320:2016, GB/T19077.1-2016, Q/0100JWN001-2013
Principle
Laser diffraction principle
Analysis
MIE scattering theory
Measuring Range
0.1�¼m-450�¼m
Channels Number
40 PCS
Accuracy error
25000hour
Dispersion
Method
Ultrasonic
Frequency:40KHz Power:60W, Time: â?¥1S
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic and manual control, freely choose
Output parameter
D10,D50,D90,D100,S/V referent parameters
Optical alignment system
Full automatic
Test Speed
Product Description
Winner2009A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Product Description
Winner2009B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01 1/4m to 1200 1/4m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.