Product Description
Winner2005A intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1m to 1000m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles.
Specification
Model Name
Winner2005A
Standard
ISO13320-1:1999 GB/T19077.1-2008 Q/0100JWN001-2013
Principle
MIE Scattering Principle
Size range
0.01�¼m-1000�¼m
Photodetectos
90pcs
Accuracy
â?¤0.5% (Deviation of D50 on national standard sample)
Repeatability
â?¤0.5% (Deviation of D50 on national standard sample)
Laser
Semi conductor Laser �»= 636.5nm, p>2mW
Service time>25000 hour
Wet dispersion
Ultrasonic
Frequency:40KHz Power:35W, Time: â?¥1S
Agitator
Revolutions Speed: 0-3000RPM (Adjustable)
Circulation
Rated Flow:8L/min Rated Power:10W
Sample tank
Volume: 350mL
Operation mode
Manual and Full automatic
Optical alignment system
Full automatic optical path alignment system
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Report Items
Particle size distribution table&graph, average diameter, Median diameter, SSA, etc.
Testing speed
Product Description Winner3006 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results. This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Product Description Winner2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200�¼m/2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Product Description Winner2009A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Product Description Winner3009A intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy. It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials,especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability. Main Features (1) Advanced testing optical path. Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range. (2)Scientific dispersion system Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system's working life. (3)Human-based operation mode Manual and Full automatic, easy choose. (4)High precision-automatic optical path calibration system It's composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state. (5)Intelligent data analysis-winner unique software support Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output. (6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter). (7)Users can design the test report output and display forms according to industry requirements. Specification Model Winner3009A Standard ISO 13320-1:1999 GB/T19077.1-2308 Q/0100JWN001-2013 Measuring Range 0.1-2000m Channels Number 100 pcs Accuracy
Winner311PRO is a new generation desktop spray particle size analyzer designed and developed mainly for droplet particle size testing of small spray equipment. Based on Winner311XP, it incorporates more unique micro-nano technologies, innovative design of external automatic mobile platform, optical path The design is more optimized, the detection channels are wider distributed, the algorithm is more stable, and the application is more intelligent. Winner311PRO can perform non-contact particle size measurement of droplets, liquid droplets, smoke, aerosol, powder mist, etc. dispersed in the air, and meets the requirements for particle size testing of inhaled aerosols, sprays, powder mist, etc. specified in the National Pharmacopoeia. , filling the gap of domestic laser particle size analyzer in measuring droplet size of small atomization devices.
Winner2308B intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200m/2000m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Product Description Winner2009B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01 1/4m to 1200 1/4m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Product Description Winner2008A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field. Specification Model Name Winner2008A Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 Principle MIE scattering principle Measuring Range 0.01�¼m-2000�¼m Channels Number 127 Accuracy error â?¤0.5% (Deviation of D50 on national standard sample) Repeatability error â?¤0.5% (Deviation of D50 on national standard sample ) Light source High performance He-Ne Laser (�»= 632.8nm, P>2MW) Lifetime>25000hours Dispersion Method Ultrasonic Frequency:40KHz Power:35W, Time: â?¥1S ,Anti-dry function Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Micro- Sample Pool Volume: 10mL ( Available) Operation Mode Full automatic/ manual control, freely choose Resolution Free distribution truly reflect particle size distribution Optical bench alignment system Japan Canon lens, Full automatic,precision is up to 0.1um Software function Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Statistic Method Volume Distribution, Quantity Distribution Statistic Comparison Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries Test Report Word, Excel,Photo( Bmp), Text etc Multiple-language Support Multiple language Support Intelligent operation Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor Testing speed
Product Description Winner2006A intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01m to 100m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data. It enables you understand materials well, such as abrasives,adhesives, agrochemical,barite, Batteries, Bentonite, Main Features (1) The laser particle size analyzer adopts a unique concentrated Fourier transform optical path. In order to better test sub-micron particles, it adopts the patented technology of orthogonal dual laser beams, and the measurement range is extended from 0.01/0.1�¼m-1000�¼m. (2) The intelligent operation mode realizes one-click testing, automatic water replenishment, ultrasonic dispersion, circulation, and drainage, which not only reduces the workload, but also achieves better repeatability after eliminating human factor errors. (3) The laser particle size analyzer adopts an automatic optical alignment system composed of a precision four-phase hybrid stepper motor. Its micro-movement accuracy reaches the micron level, so that the optical path is always in good condition. (4) Laser particle size analyzer configuration Liquid sample dispersion/preparation system: fully built-in mechanical stirring, ultrasonic dispersion, and circulation paths are integrated, and the high-power circulation pump and pipeline are optimized to effectively prevent the precipitation of large particles. (5) Software support: Original patented unconstrained free fitting technology enables particle analysis without any functional restrictions and truly reflects particle distribution. (6) Output parameters: (D50, D03, D06, D10, D16, D25, D75, D84, D90, D97, D98, set any value, S/V, D[3,2], D[4,3 ] ) Specification Model Name Winner2006A Standard ISO13320-1:1999,GB/T19077.1-2008ï¼?Q/0100JWN001-2013 Principle MIE scattering theory Size range 0.o1m-1000m Detector Channels 90pcs Accuracy error