AAC Conductors are made out of Hard drawn EC Grade (min 61% IACS) Aluminium wires stranded in successive layers in opposite direction to form the Aluminium stranded AAC Conductor up to 61 wires. All Aluminium Conductors are manufactured from electrolytically refined aluminium. They have a high level of purity; the minimum accepted level of aluminium is 99.7%. This product is also known as aluminium stranded conductor, as it is constructed of one or more strands of aluminium wire depending on the intended usage. As a consequence of this high level of purity, AAC Conductors are mainly used in areas where spacing is short and supports are close. Key Benefits : All aluminium bare conductors are used for aerial distribution lines having relatively short spans, aerial feeders and bus bars of substations. Standards: ASTM - B 231 Metric Units ASTM - B 231 TS IEC 1089 DIN 48201 BS 215 UNE 21.018
1.Applications AAAC have been widely used in power transmission lines with various voltage levels,and also used in power lines across great rivers,heavy ice area,and other places special geographical characteristics.The cables have excellent advantages of high strength,large current carrying capacity and good catenary property as well as wear-resistance,anti-crush and corrosion-proof with simple structure,convenient installation and maintenance,low cost for the line,large transmission capacity. 2.Specifications AAAC bear conductor meets or exceeds the following ASTM Specifications: B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purpose. B-399 Concentrical-Lay-Stranded 6201-T81 Aluminum Alloy Conductors 3.Product Performance (1).The electrical performance of AAAC is indicated in DC�©/km(20oC).The resistivity of aluminum alloy wire for stranded wires is: LHA1:not greater than 32.840n�©. m LHA2:not greater than 32.530n�©. m (2).The rated tensile strength of AAAC is denoted with the result of total cross-section areas of all aluminum alloy conductors multiplied by min.Tensile strength of corresponding size specified in the standard for aluminum alloy wire. 4.Material Standard The high-strength aluminum alloy conductor used for AAAC conforms to the standard JB/T 8134-1997(equivalent to IEC 60104:1987). Construction of All Aluminum Alloy Conductor
ACSR Aluminum Conductor Steel Reinforced is used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity. Aluminum alloy 1350-H119 wires, concentrically stranded around a steel core available with Class A, B or C galvanizing; aluminum coated (AZ); or aluminum-clad steel core (AL). Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease. Also available with Non Specular surface finish.
Construction This bare concentric-lay stranded conductor is constructed with a straight round central aluminum wire surrounded with one or more layers of helically-laid aluminum wires. These conductors are also manufactured as compact conductors if required. 6201 is also available. Standard ASTM B230, B231,IEC, or other standards required by customers. Applications Sino-cables type AAC is suitable for 1.Class AA as bare conductors usually used in overhead lines. 2.Class A as conductors to be covered with weather resistant materials and for conductors where greater flexibility is required. z Package in coil, steel and wooden reel, steel reel, wooden reel.
STANDARD:ASTM B399, BS 3242, BS EN50183, DIN 48201, IEC 61089, etc CAPACITY:2000ton/month AAAC aluminum alloy conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction due to the following features: 1.high strength to weight ratio 2.better sag characteristics 3.improved electrical properties 4.excellent resistance to corrosion 5.higher operating efficiency of the line Aluminum alloy conductors have a number of advantages over the use of the ACSR or all-aluminum conductors. 1.Lower power losses than for equivalent single-aluminum-layer ACSR conductors.(The inductive effect of the steel core in the ACSR is eliminated.) 2.Simpler fitting than those required for ACSR. 3.Excellent corrosion resistance in environments conductive to galvanic corrosion in ACSR. 4.Strength and sag approximately the same as for equivalent 6/1 and 26/7 ACSR conductors. 5.Outside diameters are the same for standard ACSR conductors, permitting interchangeability of fitting.
STANDARD:ASTM B231, CSA C 49,BS 215, DIN 48201, IEC 61089, etc CAPACITY:2000ton/month All Aluminum Conductors are widely used for its following features: Optimum economy is provided since the lighter weight means lower unit length coats, easier handling in installation and less-complex fittings. All-aluminum conductors have an inherent high corrosion resistance due to their homogeneous construction. AAC conductor has high current carrying capacity It is widely used for its excellent resistance to corrosion, thus ideal for use in coastal areaSuitable for low & medium voltage lines in urban are. Specification Applicable standards: ASTM/BS/CSA/DIN/IEC standards Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. Bare all-aluminum Conductors (AAC) are concentric-lay-stranded, consisting of one or more layers of wire wrapped helically around a straight round central wire. Each successive layer has six wires more than the layer immediately beneath. Greater flexibility is provided by increasing the number strands for a specific cross-sectional area. The more commonly used strandings are 7, 19, 37, 61 and 91.
Construction Aluminum 1350-H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized. Standard ASTM B230, B232, B498, B500, IEC, or other standards required by customers. Applications Sino-cables type ACSR is used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Package in coil, steel and wooden reel, steel reel, wooden reel.
STANDARD:ASTM B711, DIN 48206, IEC 61089 etc CAPACITY:2000ton/month AACSR is suitable for overhead line for long span at medium voltage, high voltage and extra-high voltage, such as used in the area of mountain, hill, or the place where snow is heavy. The AACSR has a much higher strength and its usage is ideal on long spans or under very severe mechanical conditions. 1.offers optimal strength for line design. 2.improved strength to weight ratio 3.ideal for extra long span with heavy load 4.excellent resistance to corrosion. Specification Applicable Standards: ASTM, DIN, IEC etc AACSR is a concentrically stranded conductor composed of one or more layers of Aluminium-Magnesium-Silicon Alloy wire stranded around a high strength coated steel core. The core can be of either single wire or stranded multi wire. AACSR is available with steel core of Class A, B or C galvanizing or Aluminium clad (AW). Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium. ACSR conductor is available in a range of steel strengths varying from 6% up to 40%. The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. Against any given resistance of conductor, ACSR conductor may be manufactured to have different tensile strengths as per requirement. The principal advantage of these conductors are their high tensile strength and light weight, covering longer spans with less supports. Due to the greater diameter of an ACSR conductor much higher corona limit can be obtained, giving a big advantage on high and extra high voltage overhead lines. Standards: ASTM - B 399 Metric Units ASTM - B 231 TS IEC 1089 DIN 48201 BS 215 UNE 21.018 Key Benefits: The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines. ACSR conductors consist of a solid or stranded steel core surrounded by strands of aluminum (E. C. GRADE). ACSR conductors are available in a wide range of steel, containing carbon from 0.5% to 0.85 %. The higher strength ACSR conductors are used for river crossings, overhead ground wires, installations involving extra long spans etc. Against any given resistance of conductor, ACSR may be manufactured within a wide range of tensile strength as per the requirement. Key Benefits: The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.