STANDARD:IEC60228 VOLTAGE:600/1000V CAPACITY:2000km/month Flexibility for easy handling Excellent moisture resistance Reduced overall diameter for tight duct applications without reducing insulation wall Available with EPR Insulation
STANDARD:IEC 60840 AS/NZS1429.2 VDE 0276-632 VOLTAGE:up to 110kV CAPACITY:2000km/month good electrical, mechanical and thermal characteristics excellent moisture, chemical and weather resistant low dielectric factor than PVC insulation and better dielectric constant constant performance at a long temperature range long service span LV:IEC60502-1 ,VDE 0276-603, ICEA S-95-658 ,AS/NZS 5000.1 MV:IEC60502-2 ,VDE 0276-620 ,AS/NZS1429.1 ,ICEA S93-639 ,ICEA S94-649 HV:IEC 60840 ,AS/NZS1429.2 ,VDE 0276-632
VOLTAGE:600V CAPACITY:2000km/month Single:one XLPE insulated aluminum conductor Duplex:one XLPE insulated phase conductor and one neutral conductor, duplex twisted assembly. Triplex:two XLPE insulated phase conductors and one neutral conductor, triplex twisted assembly. Quadruplex:three XLPE insulated phase conductors and one neutral conductor, quadruplex twisted assembly. Conductors:Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231. Insulation:The insulation is extruded lead-free Cross-linked Polyethylene (XLPE). The phase conductors are black, and the neutral conductor is black, identified by three extruded yellow stripes.
1.Conductor Plain, annealed electrolytic copper or Aluminum conductors, solid, circular stranded, or sectorial stranded, conforming to the applicable requirements of IEC 60228. 2. Insulation PVC or XLPE 3.Assembly Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material. 4. Armor A single strip of interlocked aluminum tape 5. Sheath PVC or PE Reinforced impact resistance Save setup space educe installation time and cost, improve efficiency Standard: BS 7870-3.11
Conductor:Aluminum AA-8000 alloy compacted conductor, Class B stranding, per ASTM B801. Soft-annealed uncoated copper compressed Class B stranding, or unilaycompressed per ASTM B8, solid wire per ASTM B3. Sizes:6 AWG-1000 kcmil On request, larger sizes available. Separator:A suitable opaque tape, as required. Insulation:Black Thermoset flame retardant cross-linked polyethylene (XLPE). Sunlight Resistant for Black color only For 600 V and 1000 V rated-40 °C and FT1
VOLTAGE:300/500V, 450/750V, 600/1000V CAPACITY:2000km/month Conductor:Class 1 solid or class 2 stranded copper conductor Separator:Mica/glass fire barrier tape Insulation:LSZH (Low Smoke Zero Halogen) or XLPE Protective Conductor:Tinned copper, full size CPC Bedding:LSZH (Low Smoke Zero Halogen) Screen:AL/PET (Aluminum/Polyester Tape) Armour:SWA (Steel Wire Armor), STA (Steel Tape Armor) Sheath:LSZH (Low Smoke Zero Halogen) or HOFR (Heat and Oil Resistant and Flame Retardant) to BS7655 or Heat resistant XLPE Sheath Color:Red, white, black
STANDARD:ASTM B230, B231, B232, B398, B399, B400 CAPACITY:5000km/week Triple extruded for clean interfaces Class 10,000 environment utilized for cable core material handling Flexibility for easy handling Excellent moisture resistance Deformation-resistant High dielectric strength Low dielectric loss Excellent resistance to water treeing Clean-stripping insulation shield without the use of a release agent Sunlight-resistant
VOLTAGE:Up to 36kV CAPACITY:2000km/month Conductor:copper, circular stranded compacted, longitudinal water-tight Conductor screening:extruded semi-conductive compound Insulation: XLPE Insulation screening:extruded semi-conductive compound Screen:copper tapes Separator:plastic foil Sheath:PE Fillers:polypropylene strings Binder Tape Bedding:polypropylene strings of polyester tape Armor:galvanized round steel Wires Serving: bituminous compound, hessian tapes, polypropylene strings with colored stripe
STANDARD:ICEA S-94-649,AEIC CS-8,Made in accordance to RUS VOLTAGE:15kV CAPACITY:2000km/month Operating Temperature Normal continuous operation 90°C for wet or dry locations (105°C optional) Overload 130°C Short circuit 250°C Rated Voltage 5, 8, 15, 25 and 35 kV. Insulation Level 100% (133% and 173% optional). Conductor Soft Copper or 1350-H19 aluminum, compact stranded. Conductor Shield Cross linked polyethylene semiconductor. Insulation Cross linked polyethylene XLPE.
1.Conductor Plain annealed copper or aluminum 2.Insulation General purpose PVC compound 3.Colour of cores Single core - red or black 2 cores - red and black 3 cores - red, yellow and blue 4 cores - red, yellow, blue and black 4. Formation 1) Single core 2) 2,3, or 4 cores - stranded together and the interstices may be filled with the sheathing compound or textile. A nonhygroscopic binder tape may be applied over the laid-up cores. 5.Bedding Black general purpose PVC compound 6.Armour Single core - Aluminum wire 2,3, or 4 cores - Galvanized steel wire 7.Sheath Black general purpose PVC compound