Voltage 450/750V or less Construction 1-core: The copper conductor is insulated with natural rubber and sheathed with natural rubber or chloroprene rubber multi-core: The copper conductor is insulated with natural rubber. Two to six insulated conductors are cabled together with extruded rubber filler, and sheathed with natural rubber or chloroprene rubber. Standard IEC 60245, GB/T 5013, or other standards required by customers. Features 1.Flexible and reliable. 2.Abrasion, corrosion, high-Heat and oil Resistant. Applications Sino cables type rubber cables are suitable for power supply to power appliances, home appliances and movable field electric equipment at 450/750V or less. Package Coil, Steel /Wooden Reel ,Wooden Reel or Steel Reel.
Voltage 450/750V or below Construction Sino-cables type PVC insulated wire is constructed with copper or aluminum conductor. The insulated conductor may be extruded with PVC(polyvinyl chloride) jacket according to different usage. Standard JB/T 8734; GB/T 5023; IEC60227, or other standards required by customers
Voltage 600V Construction Sino-cables type URD are manufactured with compacted 1350 aluminum or 8000 series aluminum alloy conductor insulated with black XLPE. Two or three insulated conductors and an neutral wire are cabled together. Single core, duplex, triplex, quadruplex are available. Standard ASTM B231, B800, UL854,ICEA S-76-474, or other standards required by customers.
Standard GB/T 12972, MT 818, or other standards required by customers. Features Certified by authoritative test labs, safe and reliable. Applications Sino-cables type mining cable is primarily used in coal cutter, moving machine, other mining purposes, or similar equipment. Package in coil, steel and wooden reel, steel reel, wooden reel.
Voltage 600V or less Construction The bare flexible stranded copper conductor is insulated with ethylene-propylene rubber (EPR). Two, three or four insulated conductors are cabled together with filler and sheathed with chlorinated polyethylene. Standard UL62, CSA 22.2, or other standards required by customers.
Voltage 600V or less Construction Sino-cables type covered line wire(ASTM) is manufactured with aluminum alloy 1350-H19, 6201-T81,or ACSR conductors insulated with low density PE, or high density PE or XLPE. Standard ASTM B230, B231, B232, B399, B498, or other standards required by customers. Applications Sino cables type covered line wire(ASTM) is primarily designed for use on overhead secondary distribution lines. Covered Line Wire is not an electrically insulated conductor and is treated as a bare conductor when installed. The insulation provides protection against circuit interruption due to weather. Package coil, steel/wooden reel, wooden reel or steel reel.
Voltage 450/750V or below Standard Q/320623 SQ 13-2009; GB/T 9330, or other standards required by customers. Features 1.high-heat resistant, low temperature, anti-aging, oil resistant. 2.all our wires are environmental-oriented, low smoke and low halogen, they are also can be fire retardant, fire resistant, or on customers needs. Applications Sino-cables type control cable is primarily used in controlling and monitoring the circuits especially in severe environment, connecting electrical meters in distribution equipments and conveying signals in automation systems, being widely used in power plant, oil, chemical, metallurgy, steel, sewage treatment, etc. Package in coil, steel and wooden reel, steel reel, wooden reel.
Voltage 600V or less Construction RHH or RHW-2 or USE-2 aluminum conductors are AA-8000 series Aluminum Alloy, compact stranded. Insulation is an abrasion, moisture, heat, and sunlight resistant black cross-linked polyethylene (XLP). Copper conductor is also available. Standard RHH or RHW-2 or USE-2 conductors meet or exceed UL Standard 44 (for RHH or RHW-2), UL Standard 854(for USE-2), Federal Specification A-A-59544, and requirements of the NEC. Or other standards required by customers. Features 1.-40----90 2.Abrasion, high-Heat and Moisture and Sunlight Resistant. 3.VW-1 or higher required by UL. Applications 1. RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the NEC. 2. May also be used as underground service entrance cable, for direct burial, at conductor temperatures not to exceed 90. 3. When used as RHH, conductor temperatures shall not exceed 90 in dry locations. 4. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90 in wet or dry locations. Package steel wooden reel, wooden reel, steel reel, in coils on wooden tray, or other requirements by customers.
Voltage 600v Construction Sino cables type soow is manufactured with bare flexible copper conductor insulated by ethylene-propylene rubber (epr). Two, three, four or five insulated conductors are cabled together with filler and sheathed with chlorinated polyethylene.
Voltage 0.6KV----35KV Construction Sino-cables YJLHS type is constructed with AA-8000 series aluminum alloy, compact stranded conductor. The conductor is extruded with XLPE(cross-linked polyethylene) insulation. Twisted assembly wrapped with a binder and covered with 5000 series aluminum alloy interlocking armor. Standard GB/T 12706; GB/T 31840; IEC60502, or other standards required by customers. Features 1.the operating temperature: -40----90, Conductor insulation is free of harmful heavy metals in compliance with RoHS. 2.good bendability, high elongation and flexibility, low spring-back, excellent properties of creep resistance, anti-corrosion and anti-oxidant, stable connection. 3.fire resistant as NH, fire retardant as ZR, low smoke halogen free as WDZ, or other requirements by customers. 4.Bending radius is only 7 times of the outer diameter of the cable and lightweight, which makes installation easier without pipeline wiring and threading. 5.Quick, easy one-step installation designed to save time, money, and energy, YJLHS type AA8000 aluminum alloy cable replaces copper power cable overwhelmingly. Applications YJLHS Type cable has been widely applied to the installation of both overhead and underground wires only in dry environments, approved for use in service, feeder and branch circuits