We sell current transformers. Please contact me for quotation.
CIRCULLATION FAN Air cooling fans are used for maintaining good air circulation and temperature in poultry farms. Our 36 air circulating fans can be used for various applications, like poultry farms, industrial buildings etc., and providing high efficiency. These fans are available in both single phase and three phase motor option. 1.Grills are plastic coated and thick diameter wire gauge (2.5mm) is used, and the gap is maintained 15mm as per international quality standards to avoid human accidents and rate entering into the fan. 2. The blades are made of compounded plastic so less chances of bending and hence less breaking chances. 3. Motor is efficient and complete thermal protection and moisture proof. 4. The CFM of fan 13000 and minimum airflow of 8.5 meters/sec. 5. Minimum positive air throws of 50ft. When we say 50 Length in practically. 6. Easy installation &Zero Maintenance
1. DC immune CT with good DC error ; 2. High precision: 0.2, 0.1,0.05 Class, 3. Good linearity; 4. Max Current:6A,10A,30A,40A,60A,80A,100A,120A,160A,200A ; 5. Ratio :1000:1; 2000:1 or 2500:1 ; 7. Pin connection/ PCB mounting ; 8. It applied in Electricity meters .
DC immune Current transformer for Electricity meter -Adopted high permeability core, high accuracy , good linearity; -Anti-combustion plastic case ; -Encapsulated with epoxy resin with strong insulation ability; -DC immune function with good DC error , conform to IEC 62053-21; - Customised shield to against the external magnetic field .
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
main parameter of 69kv CT Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA Winding accuracy class: 0.2/5P20/5P20/5P20 CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions. General particulars Rated voltage: 11 kv Rated primary current: 100 a Rated secondary current: 1a or 5a Rate burden: 5va Rated frequency: 50hz Accuracy class: 0.5 or 0.5s Temperature: as per is-2705/1992 Highest system voltage: 12kv Insulation level: 28kvrms/75kv(p) Stc: 13.1ka for 1 sec Continues thermal current: 1.2 times of rated current Core material: crgo Copper wire material: enameled wire as per is-4800 part-4 or iec-317 Insulation class/material: epoxy resin Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer Primary terminal p1 & p2 size and material Mounting base: ms 5mm thick zinc plated Rountine test :as per is-2705/1992
The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter (about 1/3 lighter), cost much lower. Applications: Electronic kwh meter Precise power meter Overcurrent protection in mechanical control apparatus Current control in industrial automation Good thermal stability Paper ctn
We are one of the leading trader and supplier of world class range of Resin Cast Current Transformers that are procured from our certified vendors of the market. These transformers are fabricated using the finest grade raw material and sophisticated technology at vendors’ end. Our offered products are widely demanded among clients due to their quality attributes like high performance, user friendly interface, longer service life and compact design. Our offered transformers are carefully examined on various parameters by our vendors to ensure their flawlessness. Specifications: Resin cast current transformers up to 33KV class As per mutual discussion
VoltageBurdenRange 1-ph.Tape wound & resin cast Upto 1100 v Prim:1 a to 10000 a; sec: 5 or 1a Bar primary ctsMetering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0 Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20 ProtectiveVk & rct reqd.Cl.Ps 3-ph.Tape wound & resin cast Upto 1100 v Prim: 200 a to 5000 a; sec: 5 or 1a Bar primary cts Metering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0 Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20 ProtectiveVk & rct reqd.Cl.Ps 1-ph.Tape wound & resin cast Upto 1100 v2.5 va to 15 vaPrim:1 a to 150 a; sec: 5 or 1a Wound primary cts Metering & Cl. 0.5 / 1.0 / 3.0 Protective Cl. 5p10 3-ph.Resin cast Upto 1100 v2.5 va to 5 vaPrim:50 a to 100 a; sec: 5 or 1a Wound primary cts Metering Cl. 0.5 / 1.0 1-ph.Resin cast Upto 1100 vSuitable for cablesSuitable for relays Core balance ctsProtectiveUpto 33 kvOf all makes 1-ph.Special cts Upto 1100 v Tape wound & resin cast Interposing & summation cts 1-ph.Resin cast cts Upto 6.6 / 11kv5.0 va to 15 vaPrimary : 1 to 3000 ampers Metering & Sec: 1, 5 and some special required ampers. Protective Cl. 0.2/0.5/1.0 Cl. 5p3/5p5/5p10/5p15/5p20 Cl.Ps As per mutual discussion
Accuracy class- 0.5 Burden- as oer customer requirement
Other Name: HPR, hydroxypinacolone retinoate serum INCI Name: HYDROXYPINACOLONE RETINOATE Molecular Formula: C26H38O3 Molecular Weight: 398.58 Appearance: Light yellow powder Purity: 10%,98% CAS NO.: 893412-73-2 EINECS No.: 412-073-2 Application: cosmetics and skin care products Supplier: ZHENYIBIO HYDROXYPINACOLONE RETINOATE is a kind of retinol derivatives.It has the function of regulating the metabolism of the epidermis and stratum corneum.It can be anti-aging, can reduce seborrhea, dilute epidermal pigment,to prevent skin aging and prevent Acne, whitening and spot-lightening effects. While ensuring the powerful effects of retinol, it also greatly reduces its irritation. It is currently used for anti-aging and preventing acne recurrence. Vitamin A alcohol derivative (HPR) is a revolutionary form of vitamin A with biopharmaceutical effects. The new HPR component of A alcohol is different from ordinary retinol in that the HPR molecule does not need to undergo metabolic conversion (generally retinol). Two-step transformation is required in the skin) to directly act through agonist receptors. Compared with retinol, it has stronger stability and is less likely to be oxidized and invalidated. It can effectively reduce fine lines and wrinkles, and lighten stains.
1. Introduction: Our wound cores are widely used in distribution transformers, especially for s13 type energy-saving transformers in china; we could provide our customers with single phase wound cores, three phase wound cores; the capacity range from 10kva to 2500kva; due to its particular technology craft, its performance is better than traditional stacked cores, especially for pole-mounted single phase transformer. 2.Manufacturing requirements: Tolerance: see demonstrated graphic; the specified requirements should be coincide with customers drawings; Standard export package
PION range of low voltage transformers comprise of double wound and custom designed transformers. PION transformers are available in open enclosed, oil cooled models to suit the customer requirement. Air cooled transformers are available in Open and Enclosed models. The enclosed models are supplied in sheet steel enclosures. Louvering is provided for the heat dissipation of the generated heat. Oil cooled transformers are housed in MS Tank and provided with adequate pressed steel radiators to ensure proper heat dissipation Oil cooled units are available with standard accessories viz. oil level indicator, drain plug / drain valve, earth terminals, unidirectional CI wheels, Oil fill hole and terminal covers.
Product description: standard current transformer is used as a standard for calibrating current transformers, Used as a standard to calibrate current transformer whose accuracy class is two or more lower than itself. The grounding pole of the machine shell must be grounded. To avoid electric shock, the conductor must be connected to the ground Technical index 1. Temperature: -5-40 2. Relative humidity: 80% 3. Allow long-term work under the rated current; More than 600A across the core. Feature; 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on nameplate This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63/(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on the nameplate 3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63 /(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on the nameplate 3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63/(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg