main parameter of 69kv CT
Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A
Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA
Winding accuracy class: 0.2/5P20/5P20/5P20
CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity KVA High Frequency Voltage Output Voltage KV High Frequency Voltage Output Current mA) Low Frequency Voltage input Change Tempera- ture() raised/ 30 minute V A YD G -1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G-5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G20 20 50 400 380 53 500 10 30 50 600 380 79 500 10 40 50 800 380 105 500 10 50 50 1000 380 132 500 10 100 100 100 500 263 1000 10 150 100 1500 500 300 1000 10 200 100 2000 500 400 1000 10
S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Symbol Loss W No-load Current (%) Impedance Voltage% High Voltage KV Tapping Range of High Voltage Low VoltageKV No-load On Load S13-M*R-30/10 30 10 ±5%±2x2.5% 0.4 Dyn11Yyn0 80 630/600 0.30 4.0 S13-M*R-50/10 50 100 910/870 0.24 S13-M*R-80/10 80 130 1310/1250 0.22 S13-M*R-100/10 100 150 1580/1500 0.21 S13-M*R-160/10 160 200 2310/2200 0.19 S13-M*R-200/10 200 240 2730/2600 0.18 S13-M*R-250/10 250 290 3200/3050 0.17 S13-M*R-315/10 315 340 3830/3650 0.16 S13-M*R-400/10 400 410 4520/4300 0.16 S13-M*R-500/10 500 480 5410/5100 0.16 S13-M*R-630/10 630 570 6200 0.15 4.5 S13-M*R-800/10 800 700 7500 0.15 S13-M*R-1000/10 1000 830 10300 0.14 S13-M*R-1250/10 1250 970 12000 0.13 S13-M*R-1600/10 1600 1170 14500 0.13 Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Low loss, low noise level, high stability This series product possesses four low and one high characteristics which are: low lose. Low noise, low temperature rising.Low partial discharge and high reliability, as well as core-hoisting free and no leakage. With the approval of national transformer quality inspection and testing center. Allthe index of the transformer achieve jb/t3837 standard
Transformer can transformer the voltage of a network into the voltage matching the system or load and fulfill power transferring and distributing.Taking the place of transformers with silicon steel core, AMDT can be widely applied in outdoor power distribution networks systems, which is magnificently energy saving and can lessen air pollution. It is especially applicable for areas with insufficient power supply and fluctuating load and where daily maintenance is hard. Since the transformer adopts a fully sealed structure, the insulating oil and the insulating medium are not polluted by the atmosphere, so it can be carried out in a humid environment, making the ideal power distribution equipment in the urban and rural distribution networks.
Execution standard GB 1094.1-2 power transformer general rules, power transformer temperature rise GB 1094.3 power transformer insulation level and insulation test GB 1094.5 "power transformer capacity to withstand short circuit" GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer GB/T 15164 load guide for oil-immersed power transformer IEC76 power transformer GB 2536 "transformer oil" 800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Performance parameters of S13 type 10kV double winding series: Type rated capacity (KVA) connection group label voltage combination (KV) no-load loss (W) load loss no-load current (%) short circuit resistance (%) High pressure range low Dy Yy. 10 10 Yyn0 / S13 - M - or Dyn11 10 6.3 6 + / - 5% Plus or minus 2 x 2.5% or + 3 x 2.5% -1 x 2.5% 0.4 40 360 340 2.8 4.0. S13-M-20, 70, 525, 500, 2.5. S13-M-30, 30, 80, 630, 600, 2.3. S13-m-5050 100 910 870 2.0. S13-m-63, 110, 1040, 1040, 1.9. S13-m-80 130 1310 1250 1.9. S13-m-100, 100, 150, 1580, 1580, 1580. S13-M-125, 125, 170, 1890, 1800, 1.7. S13-m-160, 200, 2310, 2200 1.6. S13-M-200, 240, 2730 2600 1.5. S13-m-250, 250, 290, 3,050, 1.4. S13-m-315 315340 3830 3650 1.4. S13-m-400, 4410, 452043001.3. S13-m-500, 480, 5410, 5150, 5150. S13-M-630 630 570 6200 6200 1.1. S13-m-800, 700, 7500, 7500, 1.0. S13-m-1000, 830, 10300 10300 1.0. S13-m-1250, 1250, 970, 12000, 0.9. S13-m-1600 1,170 14500 14500 0.8. S13-m-2000, 1510, 17800, 17800.0.8, 5.0. S13-M-2500, 1780 20700 20700 0.7. S13-m-3150 3150 2100 24300 24300 0.7.