These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
Supplier: Instrument transformers 11kv upto 33kv, current transformers, and potential transformers, and CT PT combined units
Services: FOB or CIF
Buyer: Transformers oil, epoxy resin and transformers core ring and rectangular both, and insulation paper, copper wire
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Current transformer.
We are one of the leading manufacturer of all types cts of any ratio. We manufacture both outdoor and indoor types. We manufacture both resin cast & oil cooled cts As per mutual discussion
We have emerged as the foremost trader and supplier of a comprehensive assortment of potential transformers. These transformers are extensively used for billing industrial clients or utility companies. Our high grade transformers are procured from the trusted vendors of the industry as per the set global norms. Manufactured using optimum quality raw material and latest technology at vendors’ end, the offered range is highly durable in nature. Optimum performance, durability and corrosion resistance are some of the salient features of our offered transformers that are highly valued by clients. Specifications: Potential transformers up to 400kv class As per mutual discussion
These accessories are used by switchgear industry for manufacture of switchgear panel for industries and residential.
GANZ current transformers meet the highest international quality standards with more than 50 years of experience in industry.