VoltageBurdenRange
1-ph.Tape wound & resin cast Upto 1100 v Prim:1 a to 10000 a; sec: 5 or 1a
Bar primary ctsMetering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0
Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20
ProtectiveVk & rct reqd.Cl.Ps
3-ph.Tape wound & resin cast Upto 1100 v Prim: 200 a to 5000 a; sec: 5 or 1a
Bar primary cts Metering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0
Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20
ProtectiveVk & rct reqd.Cl.Ps
1-ph.Tape wound & resin cast Upto 1100 v2.5 va to 15 vaPrim:1 a to 150 a; sec: 5 or 1a
Wound primary cts Metering & Cl. 0.5 / 1.0 / 3.0
Protective Cl. 5p10
3-ph.Resin cast Upto 1100 v2.5 va to 5 vaPrim:50 a to 100 a; sec: 5 or 1a
Wound primary cts Metering Cl. 0.5 / 1.0
1-ph.Resin cast Upto 1100 vSuitable for cablesSuitable for relays
Core balance ctsProtectiveUpto 33 kvOf all makes
1-ph.Special cts Upto 1100 v Tape wound & resin cast
Interposing & summation cts
1-ph.Resin cast cts Upto 6.6 / 11kv5.0 va to 15 vaPrimary : 1 to 3000 ampers
Metering & Sec: 1, 5 and some special required ampers.
Protective Cl. 0.2/0.5/1.0
Cl. 5p3/5p5/5p10/5p15/5p20
Cl.Ps
As per mutual discussion
Features: Wide range of system current Ratings Hinged terminal cover Various mounting options like DIN rail mounting, Wall mounting Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Current transformer.
We are one of the leading manufacturer of all types cts of any ratio. We manufacture both outdoor and indoor types. We manufacture both resin cast & oil cooled cts As per mutual discussion
We have emerged as the foremost trader and supplier of a comprehensive assortment of potential transformers. These transformers are extensively used for billing industrial clients or utility companies. Our high grade transformers are procured from the trusted vendors of the industry as per the set global norms. Manufactured using optimum quality raw material and latest technology at vendors’ end, the offered range is highly durable in nature. Optimum performance, durability and corrosion resistance are some of the salient features of our offered transformers that are highly valued by clients. Specifications: Potential transformers up to 400kv class As per mutual discussion
These accessories are used by switchgear industry for manufacture of switchgear panel for industries and residential.
GANZ current transformers meet the highest international quality standards with more than 50 years of experience in industry.
Using excellent material,good precious current and high efficiency. Application: Used for electricity equipment for inspection control
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.