Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
Security alarm system, smoke detector, fire detector, co detector, carbon monoxide alarm, PIR sensor.
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control And indicating equipment, or to addressable fire detection control and indicating equipment that can accept Non-addressable type detectors. An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response Threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation Dual leds for 360° visibility 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
The 442 audio/visual alarm devices are suitable for connection to 2-wire and 4-wire fire detection and alarm Systems. 441 will operate with both addressable and non-addressable fire detection control and indicating equipment. Activation is initiated upon connection of the operating voltage, allowing connection to either a switched supply or Via an addressable module. Visual, audible and audio/visual models available Red or white body available for audible alarm device Operates when the supply voltage is connected to the device Compatible with relay outputs from control and indicating equipment, or from an output module connected to addressable alarm circuit wiring Dc 24 v operation Loud sounder output of 85 db at 1 m Long-life leds Zero current load in quiescent condition
Smoke detector ms-as-02-4 Smoke detector Product information The product is a new type of photoelectric smoke detector, when it detects smoke, it will output signal immediately and trigger connected unit to work, which tell you in advance that fire will occurs and avoid unwanted loss, and take you safety and convenience. Specifications Power supply:dc12v~dc33v Work temperature:-10~+40 Static current:17-20a(24v) 17-23a(33v) Working humidity:
AC powered gas alarm 1.Semiconductor sensor 2.Power Supply: AC110/220 3.Comply EN50194 4.Fault signal, low battery warning, Stand-alone GAS Alarm from PEASAWY.COM 1.Sensor Type: semiconductor sensor 2.Power Supply: 12-24VDC 3.Standby Current: 10uA 4.Alarm Current: 23mA 5.Operation Temperature: 0¡ã- 50¡ã 6.Low battery warning 7.Self-Test Button to verify operation 8.Silence function with dual led indicator 9.Sensitivity meets EN50194 10.Alarm Sound Level: >85dB at 10 feet (3m) 11.Easy to install, move and maintain.
Hna-360 analogue addressable heat detectors are microprocessor controlled state-of-the-art detectors Compatible with popular control and indicating equipment loop protocols. An electronic thermistor sensor provides sensitive rate-of-rise alarm operation, or fixed-temperature operation When the response threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
Fire alarm bell 1.Base:aluminium 2.Fire alarm bell size:5/6" optional 3.Operating voltage:dc24v 4.High alarm sound Fire alarm bell with good performance from peasway Specifications: 1. Fire alarm bell:aluminium 2. Fire alarm bell size:5/6" optional 3. Operating voltage: 24v dc±15% (no pole) 4. Operating current: 23ma (24v dc) 5. Dimensions: ø127 x 56mm 6. Sound level: >100db (24v dc).
Gas detector, smoke detector, pir motion detector, fire alarm control panel, other security equipment.
CO Alarm 1.Electrochemical CO alarm,Fault signal warning 2.CE ROHS certified CO alarm 3.Test/Hush Button 4.LowBattery alarm. PW-916 Stand-alone CO Alarm from PEASWAY This CO alarm could be one of the most advanced designs in detection Carbon Monoxide .Battery powered models last long life (exceeds 3-year period and up to 5-years), It's the perfect choice for detecting dangerous CO poisoning. Various power input can be manufactured according to customer's special request. 1.CO ALARM Sensor Type: Electrochemical 2. Non-radioactive technology for environmental friendly 3.Power Supply: 4.5V Battery(3*AA) 4.Standby Current: 10uA 5.Alarm Current: 23mA 6.Operation Temperature: 0¡ã- 50¡ã 7.Low battery warning 8.Self-Test Button to verify operation 9.With quick fix mounting bracket for easy installation 10.Silence function with dual led indicator 11.CO Sensitivity meets EN50291 or UL2034 12.Alarm Sound Level: >85dB at 10 feet (3m) 13.Easy to install, move and maintain this co alarm 14.Five years limited warranty for the CO-sensing Operation Temperature 0 oC to 50 oC Response Times At 50 ppm, unit must alarm within 60 ~ 90 mins At 100 ppm, unit must alarm within 10 ~ 40 mins At 300 ppm, unit must alarm within 3 mins Power Source 4.5V BATTERY Standby Current 10uA Alarm Current 23mA Alarm Sound Level 85 decibels at 3 m Detection Type Electrochemical Ambient Humidity 15% to 90% Relative Humidity.
SK 36 Fire bricks are special type of brick which are form of Refractory ceramic material. It is used for inner surface lining of Boiler, furnace, kiln, fireplaces & fireboxes. Quality of Bricks: We offer various quality bricks are 50 to 55% Alumina offering high temperature resistance. Standard Sizes (MM): 230 x 115 x 75 MM 230 x 115 x 65 MM
SK 34 Fire bricks are special type of brick which are form of Refractory ceramic material. It is used for inner surface lining of Boiler, furnace, kiln, fireplaces & fireboxes. Quality of Bricks: We offer various quality bricks are 35 to 40% Alumina offering high temperature resistance. Standard Sizes (MM): 230 x 115 x 75 MM 230 x 115 x 65 MM
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
"Power Supply: 9V AA battery Sensitivity/Alarm Time : 30ppm, After 2 hours; 50 ppm, Within 60~90 minutes; 100 ppm, Within 10~40 minutes; 300 ppm, Within 3 minutes Static Current:
"Power: DC 3x1.5V AAA battery Sensitivity/alarm time: 30ppm, after 2 hours; 50 ppm, 60~90 minutes; 100 ppm, 10~40 minutes; 300 ppm, within 3 minutes Quiescent current:
"Operating voltage: AC110V or 220V Gas species: Natural gas or LPG Sensor: Semiconductor Wireless frequency: 315Mhz or 433Mhz Chip: 2262/1572 Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm&RF signal > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. adopted SCM from USA to ensure the stability, Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Can make 9V chargable back up battery "
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. MCU processing adopted,SMT adopted,good stability Malfunction auto-check indicator Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Drivable accessaries: electromagnetic valve and exhaust fan; Can make 9V chargable back up battery "