Hna-360 analogue addressable heat detectors are microprocessor controlled state-of-the-art detectors
Compatible with popular control and indicating equipment loop protocols.
An electronic thermistor sensor provides sensitive rate-of-rise alarm operation, or fixed-temperature operation
When the response threshold value is exceeded.
Durable heat sensor
Analogue detection discrimination
Dual leds for 360° visibility
Dc 24 v operation
2-wire connection to many popular loop protocols
Dip switch address setting
125 usable detector address settings per loop
Optional remote led output
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors. An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual LEDs for 360° visibility 2-wire and 4-wire models for DC 12 V and DC 24 V operation Dual LEDs for 360° visibility 4-wire models available with a N/O alarm relay output 4-wire models available with auto-reset 2-wire models available with remote LED output Connects to zone monitor for use with addressable control and indicating equipment
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. Features & Benefits: Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation Meets International Building Code (IBC) seismic requirements
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.! Features & Benefits: 1. Designed for sprinkler standards NFPA 13, 15 and 16. 2. Dual hazard operation. 3. Cross-zone (double-interlock) capability. 4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). 5. Optional Digital Alarm Communicators
Sna-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors Compatible with popular control and indicating equipment loop protocols. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and High immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
Temperature inside remains at 100.4 celsius, while exposed to 1010 celsius for 1 hr O.D.(mm):h300*w420*d360 I.D.(mm):h180*w300*d225 Weight:28 kg Volume:12 l
Temperature inside remains at 100.4 celsius, while exposed to 1010 celsius for 1 hr O.D.(mm):h300*w420*d360 I.D.(mm):h180*w300*d225 Weight:28 kg Volume:12 l
2 or 4 wire models * Dual LEDs for 360�‹visibility * Advanced detection and discrimination algorithms * Easy installation and maintenance * Sleek low-profile housing design * Durable sensor head, no need for replacement * SMD circuit board design-satisfactory quality and reliability guaranteed * Integrated heat detector for NB326-H-2 and NB326-H-4 models * N/C (normal/close)-N/O (normal/open)selectable relay output * AR (Auto Reset) function for security systems (optional for 4 wire models) * Sensor base option: standard and Shottky Diode.